Coaxial cable, LAN cable, electrical cable, control cable.OEM
Power cable, PVC cable, PVC wire, ABC cable, rubber cable, XLPE cable, aerial cable, flexible wire.OEM, ODM
Tank feeding bulk powder Tank Loading Mass Flow Meter realizes quantitative and accurate loading and one-button operation of powdered bulk materials, greatly improves loading efficiency, saving labor costs and improves working environment. At the same time, combining with other intelligent automation devices, the bulk powder process is fully automated, which is a new type of environmentally-friendly quantitative loading equipment. Applicable: cement, fly ash, mineral powder, alumina powder, calcium carbide powder, etc. Accuracy: ±1.0%; Flow rate: 250~800m³/h Product Features 1. Like a gas station, loading as required quantity; 2. One button to start loading automatically; 3. Since the release process is automatic and stable, accurate loading, the equipment can protect the environment and improve the working condition; 4. Height of 700mm is enough for installation, and the modification period is as short as 1-2 days; 5. It can be connected to Fengbo intelligent cloud service platform to realize early diagnosis, early warning, remote guidance and rapid maintenance. There are more than 300 successful applications and a thousand sets are installed in the cement, power, and metallurgy industry.
Electrical cable wire.
TVVB, shaft cable and special cable.
ABC cable, power cable/electrical cable, armoured cable, control cable, rubber cable, welding cable, building wire/electrical wire, overhead line, instrument cable, service drop cable.
Overhead cables, XLPE insulated power cable, control cable, instrument cable, PVC insulated wire.Export, agent
Optical fiber cables.
Air compressor,screw air compressor,air ompressor parts ,accessories,air dryer.
*all equipments are produced by the professional technicians of our own factory, with best price and high quality. We look forward to cooperating with you. Rotary dryer introduction- Rotary drum dryer adopts the means of drum marginal transmission, flange connection, direct heat transfer. It is used for drying fertilizer, ore, mineral, metal, coal, sand, carbon, wood chips, slag, animal manure, etc. Rotary dryer working principle- Materials are sent to hopper of rotary dryer by belt conveyor or bucket elevator, then enter the barrel installed with slope to horizontal line from the higher side, and hot air enters the barrel from the lower side, and then materials and hot air mix together. Materials go to thelower side by gravity when the barrel is rotating. Lifters on the inner side of barrel lift materials up and down in order to make materials and hot air mix completely, which is designed to improve the producing efficiency of rotary dryer.
Gas sensors, industrial gas detectors, alcohol testers, and domestic gas alarm.
Rubber flexible cable is used for household electrical appliances electrical tools and various mobile electrical equipments of ac rated voltage 450/750v or lower. The rubber flexible cable carries out the standard: Rated voltage 1kv ( um=1.2kv) Gb5023-1997 rubber flexible cable voltages up to and including 450/750v. Jb8735-1998 rubber flexible cable and flexible wire voltages up to and including 450/750v. The length of the cable in coil should be 100m, and that on drum should be more than 100m; the length of pieces of shorter (no shorter than 10m each) should be no more than 10% of the total length package; it depends on final both agreements with length error allowance no more than 0.5%.
•relative immunity to short circuits caused by external forces (wind, fallen branches), unless they abrade the insulation. •can stand in close proximity to trees and will not generate sparks if touched. •simpler installation, as crossbars and insulators are not required. •less cluttered appearance. •can be installed in a narrower right-of-way. •at junction poles, insulating bridging wires are needed to connect non-insulated wires at either side. Abc can dispense with one of these splices. •less risk of a neutral-only break from tree or vehicle damage, increasing safety with tnc-s systems. •electricity theft is made harder, and more obvious to detect. Drum or as your request
(1).Application: ABC Cable Primarily used for 120 volt overhead service applications such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crosslinked polyethylene(XLP)insulated conductors. (2).Construction: Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs.) Allowable Ampacities+ Size (AWG) Stranding Insul. Thick. (Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY AAC Neutral-messenger Pekingese 6 1 45 6 7 563 10.36 61 61 85 70 Collie 6 7 45 6 7 563 10.36 64 64 85 70 Dachshund 4 1 45 4 7 881 10.36 92 92 115 90 Spaniel 4 7 45 4 7 881 10.36 96 96 115 90 Doberman 2 7 45 2 7 1350 14.88 147 147 150 120 Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160 Wooden Drum.
XLPE insulated high voltage power cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 35kV or lower, and also used for Subway,Power station,Factory and Mine.It can be installed underground, in pipe, in trench or in tunnel. XLPE Cable not only has excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
XLPE insulated power cable is used to transmit power on the power tansmission and distribution of AC,rated voltage 35kv or lower.Incompatison with PVC insulation cable,It boasts not only excellent electric character,mechanical chatacter,heat and agingresistant character,environmental stress-resistant chatacter and chemical corrosionresistant chatacter,but simplw structure,light weight,no restiction by laying drop,and hight temperature allowance for long-term working as well. Executive standard 1)GB/T12706.1-2002(Equivalent IEC 60502) Rated voltage 1kv (Um=1.2kv)and power cable 2)GB/T12706.2-2002(Eqquivalent IEC60502-2)Rated voltage6 kvUm=7.2kv and Um=36kv power cable 3)G/BT12706.3(VOLTAGE Grade Overtep IEC 60502-2) Rated Voltage3.5V Um=40.5kv and power cable. Working consitions: 1) This maximum working temperatuie of thr conductor temperature is +90. During having a short (lasting less than 5 seconds )the maximum temperature of the cable conductor shall not be above +250 Environment temperture should be no lower than+0 for laying the cable. 2) Bending radius allowance of the cable: Single core cable:No steel tape cable 20D,steel tape cable 15D Cores cabel: No steel tape cable 15D steel tape cable 12D Notes: D ptactical esternal diameter of cable. Wooden drums
CU conductor PE insulation Twisted electrical wire belong to the series of laying electrical wire,which is mainly suitable for laying at the fixed places.It is widely used as lighting,connectors of drive, electric equipments,instrument and telecommunication equipments.The rated voltage is 450/750V(U0/U) or below.Part of the plastic wires are used at the equipment with AC rated voltage up to 300/300V . Electric wire is usually PVC insulated wire.This system include the below types: BV,BV-90,BVR, BVV,BLVV,BVVB,BLVVB,RVB,RVS,RVV BV Copper (aluminum) conductor PVC insulated w BLValuminum) conductor PVC insulated wires BVR Copper conductor PVC insulated flexible wires)* Copper (aluminum) conductor PVC insulated PVC sheathed round wires * Copper (aluminum) conductor PVC insulated PVC sheathed flat wires * Copper conductor PVC insulated flat flexible connectors * Copper conductor PVC insulated PVC sheathed round flexible connectors* Sizes: 0.5-185mm2* Standard: GB Standard and IEC Standard. GB 5023.11997450/750V or below PVC insulated electric wires,JB 8734.15-1998450/750V or under PVC insulated cables,electric wires and flexible wiresand Q/ZEL 02-2002Piastic insulated electric wires and cables.GB 5023.17-1997 is identical to IEC227,and type are same as the stipulation of IEC,technical specification is just the same,and more we have extended the range of the type to fit for the requipment of the consumers. We can also produce as per the other special requirements Coil
Rg59-coaxial cable Specification: 1.Construction data Center conductor - bare copper; ¦=0.81mm Dielectric - pe; ¦=3.70.05mm Shield - aluminium Braid ¿c aluminium; coverage=60% Jacket - pvc; ¦=6.00.1mm 2.Electrical data Impedance (+) - 752 Capacitance (pf/m) ¿c 52 Velocity ratio (%) ¿c 85 3.Other test parameters Please contact with us at once, and get more test parameters. Use: Catv, cctv, and connection cable for satellite systems of lower attenuation. According to made products
RG58 /U-Coaxial Cable Specification: 1. Construction data Center conductor - bare copper; ¦=0.813mm Dielectric - pe; ¦=4.5í0.05mm Shield - no Braid ¿c tinned copper; coverage=95% Jacket - pvc; ¦=5.0í0.1mm 2. Electrical data Impedance (+) - 50í2 Capacitance (pf/m) ¿c 93.5 Velocity ratio (%) ¿c 66 3. Other test parameters Please contact with us at once, and get more test parameters. Use: Connection cable for communication systems of lower attenuation. According to made products
Solar cable, welding cable, power cable, electrical wire.Shipping