Non-woven protective products and medical instruments.
Guidewire, catheter, manifold, monitor tubing.Insert molding, tip forming, side hole positioning, pad printing, mold design and fabrication, extrusion ,packing, sterilization
Wook handicraft.
Ferrovanadium, ferrochromium, ferrosilicocalcium, ferrosilicon, ferrophosphorus, ferromanganese, ferromolybdenum, niobite ferronickel, ferroboron, ferrotitanium, ferrotungsten.
Latex clothes, inflatable latex clothes, latex accessories.
Tellurium, cadmium, indium, bismuth, gallium, germanium, antimony, selenium, tin.
Medical equipment.
Specification: Measurement range : So2(micro-flow ndir):0-2000 ppm No(micro-flow ndir): 0-2000 ppm Co(micro-flow ndir): 0-5000ppml O2(electrochemistry):0-25% vol Resolution: So2/no/co:1 ppm, o2: 0.01% Precision:ía2% fs Response time:ín15s Dimension:rack type 19 inch 3u Weight:approximately 10kg 3u casing
Gas parameter Measurement principle: Micro-flow ndir : so2, no, co, co2 Electrochemistry: o2 Measurement range : So2:0-2000ppm No: 0-2000ppm Co: 0-5000ppm Co2:0-25% O2: 0-25% Resolution: So2/no/co: 1ppm Co2/o2: 0.01% Precision: So2, no, co, co2 : 1%fs O2: 2%fs Temperature parameter Measurement principle: Ambient temperature:thermistor Flue gas temperature: thermocouple Range: Ambient temperature :-10-100íµ Flue gas temperature : -10-600íµ Resolution: Ambient temperature 1íµ Flue gas temperature 1íµ Precision: Ambient temperature ía1íµ Flue gas temperature ía2íµ Pressure parameter: Measurement principle: Diff. Pressure: silicon diff. Pressure chip Ambient pressure: silicon pressure chip Range: Diff. Pressure:-50hpa ...+50hpa Ambient pressure: 70kpa...120kpa Resolution: Diff. Pressure: 1pa Ambient pressure: 0.01kpar Precision: Diff. Pressure: ía2pa or 5%rel Ambient pressure: ía0.5 kpa or 2 % rel.
Specification: Measurement range ch4:0-100%, co2:0-50%, o2:0-25%, h2s:0-9999ppm Precision:co2/ch4:ía2%, o2:ía3%, h2s:ía4% Resolution:ch4/co2/o2:0.01% , h2s: 1 ppm Respond time:less than 20s Warm up: 10min Output: rs232 Power: ac220vía10% 50hzía1hz Weight: 10kg Dimension: rack type19 inch 3u 3u casing
Minerals.
Polyester paper cone yarn.
Ferro vanadium, vanadium pentoxide, vanadium slag.
Beauty equipment, beauty machine.
Laser therapy watch, knee pain relief laser therapy device, hand-held laser therapy device, multi-functional pain relief laser, low level laser treatment instruments, gynecology laser therapy device, slimming belt, prostate therapy device, breast light screening device, oxygen generators.
Yarns: close virgin spun polyester yarn.
Barite.
Esu pencil, bipolar forceps, reusable bipolar forceps cable, cosmetic electrode, LED medical examination lamp, medical footswitch, smoke evacuator.
Medical device, health care equipment, PV system, wind generator.
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index Input characteristics Voltage measuring range 0 200V 800V, automatic cutting gear. Current measurement range Clamp transformers three types 5A 25A standard 100A 500A optional 400A 2000A optional Phase angle measuring range 0 359.99 Frequency measurement range: 45 55Hz. Voltage channels three channel UA UB UC Current channels three channel IA IB IC Maximum harmonic analysis times 63 times. Maximum continuous storage period in 1 minute interval: 18 months. Accuracy Measurement of electrical parameters section: Voltage 0.2% Frequency 0.01Hz Current, power 0.5% Phase 0.2 Power quality section Fundamental voltage tolerance 0.5% F.S. Fundamental current tolerance 1% F.S. Phase between fundamental voltage and current measurement erro0.2