YH-830 non-invasive ventilator has a double-layer design, with an independent humidifier and humidification function, the effect will be better. Its maximum inhalation pressure is 30cmH20, with ST and target tidal volume setting modes, and the breathing rate is 54 times/min. Each exhalation can perfectly trigger the ventilator, and it is easy to synchronize with breathing and can maintain normal inhalation intensity , Form a good synchronization with the large flow. It has relevant CE&FDA certification. The price is $9,000/set.
ACM812 ventilator has aviation quality, professional technology and popular models. It has two modes, namely pneumatic drive and electric control, which integrates invasive, non-invasive and manual. It facilitates sputum suction and avoids cross-infection. It is easy to carry, moisture-proof, shock-proof and smoke-proof. The ACM812 ventilator has three power sources: A/C, D/C and car power, suitable for children and adults. You can adjust the volume, limit the pressure, time switch, and can demonstrate lung protection strategies. ACM812 ventilator has relevant CE&FDA certification. The price is $15,000/ set.
Humidified high flow nasal cannula oxygen ventilator
ENV-40-DO Dissolved Oxygen Probe Operating principle A galvanic dissolved oxygen probe consists of a polyethylene membrane, an anode bathed in an electrolyte and a cathode. Oxygen molecules defuse through the probes membrane at a constant rate (without the membrane the reaction happens to quickly). Once the oxygen molecules have crossed the membrane they are reduced at the cathode and a small voltage is produced. If no oxygen molecules are present, the probe will output 0 mV. As the oxygen increases so does the mV output from the probe. Each probe will output a different voltage in the presence of oxygen. The only thing that is constant is that 0mV = 0 Oxygen. (A galvanic dissolved oxygen probe can also be used to detect the Oxygen content in gases). This Dissolved Oxygen probe can be fully submerged in fresh or salt water, up to the BNC connector indefinitely. ENV-40-DO Dissolved Oxygen Probe Typical Applications * Standard Lab use * Field use * Hydroponics * Fish keeping * Wine making * Food Safe * Environmental monitoring ENV-40-DO Dissolved Oxygen Probe Specifications * Reads: Dissolved Oxygen * Range: 0 - 100 mg/L * Response time: ~0.3 mg/L/per sec * Max pressure: 3,447 kPa (500 PSI) * Max depth: 343 meters (1,125 ft) * Temperature range: 1 - 50'C * Weight: 52 grams * Dimensions: 16.5mm x 114mm (0.5" x 4.48")
Fop-m260 fiber medical pressure sensor application Cardiovascular: lv pressure, arterial bp Pharmacology: drug and fluid injection Neurosciences: intracranial pressure Spine - intradiscal pressure Bone - intramedullary pressure Urology - bladder/ureter pressure Mri rfi gating - arterial blood pressure or lv pres-sure for image gating Respiratory / pulmonology Otorhinolaryngology: inner ear pressure Ophthalmology: intraocular pressure Gastro intestinal Fop-m260 fiber medical pressure sensor specifications Pressure range: -300mmhg to 300mmhg Resolution: 0.1mmhg System accuracy: 3mmhg Zero thermal effect:
Model:AT-818 Breathalyzer Display:blue backlight 3-digit LCD screen Sensor:High-precision semiconductor sensor Detection Range:0.000-0.199% BAC 0.00-1.990 ,BAC 0.000-0.995mg/L (BrAC) Alarm point:0.050% BAC 0.500 ,BAC 0.250mg/L (BrAC) Accuracy:-0.01 to +0.01%BAC at 0.05%BAC Response Time:
Sensor type:Advanced NM hot-wire alcohol sensor Test Range:0.00-0.19% or 0.00-1.99 BAC / 0.00-0.95 mg/L / 0.00-199 mg/100mL Accuracy:-0.01 to +0.02% Mouthpieces:6 mouthpieces included Backlight:Blue Weight:66g Dimension:112x77x26mm Power Supply:3 x 1.5V"AAA"size alkaline batteries/ Auto power off Ambient Conditions storage: ; operate: 5 to 40 Certificate:CE,ROHS 1 x Breathalyzer 1 x User Manual Inner package: color box Meas:51x27x43.5cm Qty per carton: 60pcs G.W / N.W: 14.50kg / 13.50kg
with advanced design and quality, nuojia provides series transfer chair ,electric rotating bed and smart standing wheelchair etc to elder and semi-disable, detail information please contact us.
Technical Parameters Parameter Application This product is used in conjunction with 3mL (100IU/ml) insulin refills and standard insulin pen needles produced by Novo Nordisk, Eli Lilly and Sanofi for subcutaneous insulin injection Length 190mm Weight 49g(Refill and needle not included) Minimum dose 0.1U Waterproof IPX0 Battery DC3.7V,90mAh,Rechargeable Li-Ion Polymer Battery Manu Open type, some functions can be turned on or off freely Injection rate charging method The screw is automatically reset, and the loaded amount of medicine is automatically calculated. Dose setting range 0.5u~60.0u Dose step size 0.1u Save function Injection record storage (date, time and number) Energy saving Screen sleep mode Maximum charge 310U Insulin cartridge volume 3.0mL Warning item parameters: Low voltage Low voltage prompt when the voltage is lower than 3.5V Low dose Low liquid prompt when the liquid is less than 20U Finished medicine When there is no infusion of liquid medicine, the reminder of the end of the medicine Block The icon on the display flashes, the indicator light flashes, and there is a beep
PSC-T54U Infrared Pyrometer for Glass Industry Applications PSC-T54U Non-Contact Infrared Pyrometer Description The digital PSC-T54U is designed specifically for glass surface applications. Offering a wide temperature range from 350 to 1200'C, it is essential for thin glass surface measurement. The robust and compact stainless steel housing ensures operation under even the most difficult ambient conditions. With a minimum response time of only 60 ms, the PSC-T54U is ideal for fast measuring tasks and spot sizes from 5mm. The standard 0/4 to 20 mA linear output signal allows seamless integration into existing measurement and control systems. The PSC-T54U boasts a galvanically isolated RS-485 interface and therefore is bus-compatible and uses Modbus RTU protocol. PSC-Spot software enables simple parameter adjustment of emissivity, sub temperature ranges, response time and data storage when joined to a PC through an RS-485 to USB connection. PSC-T54U Non-Contact Infrared Pyrometer Features * Designed for non-contact temperature measurement of ultra-thin glass < 1mm thickness * Temperature Range: 350 to 1200'C * High Resolution Optics - Field of View 70:1 * Compact, Rugged Stainless Steel Housing with Protective Hardware for Harsh Environments * Digital RS-485 and Analog 4-20mA Interfaces for Ease of Installation in Existing Measurement & Control Systems * Worldwide Application Specialist Support PSC-T54U Non-Contact Infrared Pyrometer Specifications * Temperature Range: 350 to 1200'C (662 to 2192'F) * Spectral Range: 7.8um * Accuracy: 0.6% of Measured Value in 'C or 1K * Reproducibility: 0.3% of Measured Value in 'C or 0.5K * Output: 0/4 to 20 mA, Temperature Linear, Max Load 700 ohm * Power Requirement: 24 V DC ±25%, Residual ripple 500 mV * Power Consumption: Max. 1.5W * Operating Temperature: 0 to 70'C (32 to 158'F)
upnmed compatible Goldway Toco fetal probe Product Description Goldway Toco fetal probe
Sheath tubing for introducer sheath Occluder, vena cava filter and Stent delivery system. Good biocompatibility, fully radiopaque with smooth tip. Sizes: 4Fr to 15Fr.
Radiopaque HDPE material with different color. Suitable for .035'' or .038'' guide wire passing through. Very smooth surface and excellent tip configuration. Sizes: 4Fr to 15Fr.
Production Description: +Spiral design ensures precise pressure. +Improved release handle makes instant and easy inflation and deflation. +Overpressure protective device provides safer prssure control.
Production Description: +Medicine reservoir makes of silicone with stabilized resilience,to get the goal of continuous inject medicine by controlling the flow rate. +Use Germany UV glue water and unique cementation technique to solve the problem of leakage. +Use refined filter to solve the problem of mote pollution. +Use PCA controller and patients can control the replaced dosage. +Use computer measurement system. View data is reliable. +For single use, non-electric power,it’s more convenient, safe and effective.
Sirolimus Eluting Coronary Stent System A Value - Added DES...... Production Description: +100% biodegradable PLGA Coating +Controlled drug release for continuous effect
Production Description: +TPU material with mark and it can be visiable under X Ray +The catheter has a smooth side hole to ensure smooth drainage +Unique elbow design
Properties: Intervention equipments Type: Embolization equipments Brand name: Yilsonmed Model number: 100ml/150ml/200ml Place of origin: Guangdong, china (mainland)
Sirolimus-eluting coronary stent system plga coating Properties: Intervention equipments Type: Embolization equipments Brand name: Codura Model number: 2.5mm - 4.0mm Place of origin: Guangdong, china (mainland) Licence number: Iso13485 Material: L605 cobalt-chromium Stent location: Blood stent
ITG M04 oxygen sensor can used for Medtronic Covidien Puritan-Bennett 760 840 980 GE iVent eVent BD Carefusion Bird Avea SiPAP Ventilator Biomedtech Australia OnePlus IHT Hypoxicator Go2Altitude Draeger Infinity Delta eVent Inspiration LS Hamilton 396008, 396009, Galileo, Raphael, Arabella, 51254, G5 IMT medical Bellavista Siemens Servo 900C, 900D, 700, 710, 300, V710 300 Spacelabs 90513