Carpet grip Different size, different big nail type(wood, concrete, wood&concrete), also different quality , all depend on your choose Standard export packing
Carpet sealing tape Environmental friendliness carpet sealing tape with competive and reasonable price Standard export packing (cartons)
Features: 1. Portable stage, mobile stage. 2. Max loading capacity, 1000KGS/SQ.M. 3. Anti-rust stage riser, anti-slip & fire resistance & waterproof 4. Ideal used for outdoor concert stage. 5. Adjustable height. 6. Environment friendly. 7. 5 years guarantee.
Wedding Cuff Love Wedding Ring Stainless Steel Jewelry We are factory to producing stainless steel, tungsten, ceramic jewelry etc. Any needs please let us know. All size in US, EURO etc.
Bitto 100% acrylic sheets Bitto solid surface material is a high-tech product composed of 43% mma, 52% ath, 2% other activators and 3% natural pigments, bitto 100% acrylic solid surface can be grouped into 4 categories characterized by the size and density of the particulate. Pe film
50%ápolyester and 50% acrylicá 60 inches X 50 inches
WSD-007 Material:full Carbon Fiber Surface: leather Size:135*270 Weight: about 150g
Front runner.
As for Urine Reagent Analysis Strip Uncut Sheets , we have various parameters ranging from 1 to 12 . We can provide you strip and uncut sheet URS format with high quality and competitive price PRINCIPLE AND EXPECTED VALUES URS Ascorbic acid: This test involves decolorization of Tillmann's reagent. The presence of ascorbic acid causes the color of the test field to change from blue-green to orange. Glucose: This test is based on the enzymatic reaction that occurs between glucose oxidase, peroxidase and chromogen. Glucose if first oxidized to produce gluconic acid and hydrogen peroxide in the presence of glucose oxidase. The hydrogen peroxide reacts with potassium iodide chromogen in the presence of peroxidase. The extent to which the chromogen is oxidized determines the color which is produced, ranging from green to brown. Low amounts of glucose are normally excreted in urine.3 Glucose concentrations as low as 100 mg/dL, read at either 10 or 30 seconds, may be considered abnormal if results are consistent. At 10 seconds, results should be interpreted qualitatively. For semi-quantitative results, read at 30 seconds only. URS Bilirubin: This test is based on azo-coupling reaction of bilirubin with diazotized dichloroaniline in a strongly acidic medium. Varying bilirubin levels will produce a pinkish-tan color proportional to its concentration in urine. In normal urine, no bilirubin is detectable by even the most sensitive methods. Even trace amounts of bilirubin require further investigation. Atypical results (colors different from the negative or positive color blocks shown on the color chart) may indicate that bilirubin-derived bile pigments are present in the urine specimen, and are possibly masking the bilirubin reaction.
General Information The Urinalysis Reagent Strips (Urine) are firm plastic strips onto which several separate reagent areas are affixed. The test is for the detection of one or more of the following analytes in urine: Ascorbic acid, Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite , Leukocytes and so on.
SUMMARY Bilirubin: This test is based on the coupling of bilirubin with a diazotized dichloroaniline in a strongly acid medium. The colors range from light tan to reddish-brown. Ketone: This test is based on the reaction of acetoacetic acid with sodium nitroprusside in a strongly basic medium. The colors range from beige or buff-pink color for a Negative reading to pink and pink-purple for a Positive reading. Specific Gravity: This test is based on the apparent pKa change of certain pretreated polyelectrolytes in relation to the ionic concentration. In the presence of an indicator, the colors range from dark blue or blue-green in urine of low ionic concentration to green and yellow-green in urine of higher ionic concentration. Blood: This test is based on the pseudoperoxidase action of hemoglobin and erythrocytes which catalyzes the reaction of 3,3, 5, 5-tetramethyl-benzidine and buffered organic peroxide. The resulting colors range from orange to yellow-green and dark green. Very high blood concentration may cause the color development to continue to dark blue. pH: This test is based on the well known double pH indicator method, where bromothymol blue and methyl red give distinguishable colors over the pH range of 5-9. The colors range from red-orange to yellow and yellow-green to blue-green. Protein: This test is based on the protein error-of-indicator principle. At a constant pH, the development of any green color is due to the presence of protein. Colors range from yellow for a �??Negative�?? reaction to yellow-green and green to blue-green for a �??Positive�?? reaction. Urobilinogen: This test is based on a modified Ehrlich reaction in which p-diethylaminobenzaldehyde reacts with urobilinogen in a strongly acid medium. Colors range from light pink to bright magenta. Nitrite: This test depends on the conversion of nitrate to nitrite by the action of Gram-negative bacteria in the urine. The nitrite reacts with p-arsanilic acid to from a diazonium compound in an acid medium. The diazonium compound in turn couples with 1,2,3,4-tetrahydrobenzo(h) quinolin to produce a pink color. Leukocytes: This test is based on the action of esterase present in leukocytes, which catalyzes the hydrolysis of an indoxyl ester derivative. The indoxyl ester liberated reacts with a diazonium salt to produce a beige-pink to purple color. Ascorbic Acid: The composition comprises of a complex chelating agent with a polyvalent metal ion in its higher state and an indicator dye that can reacts with the metal ion in its lower state to produce a color change from blue-green to yellow.
General Information The Urinalysis Reagent Strips (Urine) are firm plastic strips onto which several separate reagent areas are affixed. The test is for the detection of one or more of the following analytes in urine: Ascorbic acid, Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite , Leukocytes and so on.
INTENDED USE The HCG s/u Gold Rapid Screen Test(RST)is a chromatographic immunoassay for the early detection of human chronic gonadotropin (HCG) in serum/plasma or urine specimens. INTRODUCTION HCG is a glycoprotein hormone secreted by the developing placenta during pregnancy. The concentration of HCG in serum is approximately equal to the concentration in urine. The concentrations of HCG in urine and serum continue to rise during the first trimester of pregnancy to as high as 100,000 mIU/ml. HCG appears in urine shortly after conception, and continues to increase during the early stages of pregnancy, making it an excellent indicator for the detection of pregnancy. PRINCIPLE The membrane of the test device was coated with anti HCG antibodies on the test region and goat anti mouse IgG antibodies on the control region. During the test, urine specimen is allowed to react with the HCG monoclonal antibody-colloid gold conjugate, which was pre-dried on the test strip. The mixture then moves upward on the membrane chromatographically by capillary action. For a positive specimen, the conjugate binds to the HCG forming an antibody-antigen complex. This complex is captured by anti HCG antibody immobilized on the test region (T) and produces a pink color band when HCG concentration is equal to or greater than 25mIU/ml. Absence of this colored band in the test region suggests a negative result. To serve as a procedural control, a colored band at the control region(C) will always appear regardless the presence or absence of HCG. STORAGE The kits should be stored at temperature 4-30°C� the sealed pouch for the duration of the shelf life (24months).
Product suitability: 3-12 years old Type: Mosaic Paste Production Colors: Various Welcome to email for consultation!
Led display,led screens,led billboard,digital signage,led display outdoor,video wall,led wall,led strip,.
Syphilis Test INTRODUCTION Anti-Syphilis Test is a rapid direct binding test for the visual detection of anti-syphilis antibodies in serum as an aid in the diagnosis of syphilis infection. Test results are read visually without any instrument. It is based on the principle of double antigen sandwich immunoassay for determination of syphilis antibodies in serum. Purified recombinant syphilis antigens are employed to identify anti-Syphilis antibodies specifically. This one step test is very sensitive and only takes about 10 to 20 minutes. Syphilis Test SPECIMEN COLLECTION For serum, collect blood into a container without anticoagulant. Allow the blood to clot and separate the serum from the clot. Use the serum for testing. If the specimen cannot be tested on the day of collection, store the serum specimen in a refrigerator or freezer. Bring the specimens to room temperature before testing. Do not freeze and thaw the specimen repeatedly. Syphilis Test PROCEDURE Strip 1.When you are ready to begin testing, open the sealed pouch by tearing along the notch. Remove the test from the pouch. 2. Immerse the strip into the container with the arrow end pointing towards the container. Do not immerse past the MAX (maximum) line. Take the strip out after 8-10 seconds and lay the strip flat on a clean, dry, onabsorbent surface (e.g., mouth of the serum container). 3.Wait 10-15 minutes and read result. Do not read results after 20 minutes. Cassette 1. Open a pouch containing a cassette, lay the cassette. 2. Using the plastic pipettor provided, draw about 2-3 drops (100mL) the sample into the sample well of the cassette. 3. Read results within 10-15 minutes. Do not read results after 20 minutes. INTERPRETATION OF RESULTS Negative: Only one pink band appears on test region of the Cassette. This indicates that there is no detectable Anti-Syphilis in the serum. Positive: Two pink bands appear on test region of the Cassette. This indicates that the specimen contains detectable amount of Anti-Syphilis. Invalid: If without colored band appears on test region, this is an indication of a possible error in performing the test. The test should be repeated using a new device. Syphilis Test PRECAUTION: 1. Must use fresh specimen and avoid repetitive freezing, the result will be invalid 2. Use it before expiry date. 3.The package of kit should not be opened until it reaches the room temperature if it taken out from the refrigerator. 4 .Old Serum can not be used. If the serum is thick, it can be used only after being separated. Syphilis Test LIMITATIONS The test is for in-vitro diagnostic use only.
Exhibition carpet.
LED aluminium profiles like aluminum strip.
Acrylic display.
Shower room, wallpaper.