¡ü¡à0.004a (0.5-1a) Photometric reproducibility: ¡ü0.001a (0-0.5a) ¡ü0.002a (0.5-1a) Stability: ¡ü ¡à0.001a/h Noise: ¡ü ¡à0.001a Baseline flatness: / ¡ü ¡à0.002a Power: 100-240v, 50/60hz Light source: deuterium & tungsten-halogen lamp Accessories: Uv1700 spectrophotometer 1 Set Power cable 1 Pc Operation manual 1 Pc Certificate of quality checking 1 Pc Fuses (2 a) 2 Pcs 10mm quartz cuvettes 2 Cases Packing list 3 Pcs Compact disc 1 Pc (uv1700pc only) Rs-232 cable 1 Pc (uv1700pc only) Dust cover 1 pc Software specifications: 1. Such operation as photometric measurement, spectrum measurement, quantitative measurement, kinetic measurement are offered in uvcon windows applications. 2. Single-wavelength quantitative measurement can be measured with several kinds of arithmetic calculation methods to meet users¡¯ demand. 3. Curves can be measured and recalled in memory with data-handling of arithmetic calculation smooth, abs to/ from %t conversion and peak pick. 4. The measured data and graphics can be stored on pc/ printed/ output for reports. Outstanding quality, keeping constant improving Standard export packing
Introduction: Uv752 is single beam spectrophotometer that analyzes specimen materials in the ultraviolet and visible spectral d software this product is capable of charting and storing the scan results. Uv752 specifications: Model Uv752 752pc Optical system: single beam, grating 1200 line/mm Wavelength range: 200nm-1000nm Wavelength accuracy: ¡à2.0nm Wavelength reproducibility: 1nm Wavelength readability: 0.1nm Special bandwidth: 4nm Photometric range: 0-125%t, -0.097-2.70a, 0-1999c Photometric accuracy: ¡à0.5%t Photometric reproducibility: 0.2%t Stray light: ¡ü0.5%t (ƛ 220, 340nm) Stability: ¡ü0.004a/1hr/500nm (after 30min warm up) Light source: deuterium & tungsten-halogen lamp Power: 220v 50hz Display: Lcd(2*20) Data output: Rs-232c Analysis software: Without With Dimensions: 440x370x200mm Weight: 17kg Accessories: 1. Uv752 spectrophotometer 1 set 2. Power cable 1 pc 3. Operation manual 1 pc 4. 10mm glass cuvettes 4 cases 5. 10mm quartz cuvettes 2 cases 6. Dust cover 1 pc 7. Printer cable 1 pc Standard export packing
Features: Specifications: Model723723pc723pcs Optical system: single beam, grating 1200 line/nm Wavelength range:325-1000nm Wavelength accuracy: ¡à1nm Wavelength reproducibility:¡ü0.5nm Wavelength readability:0.1nm Spectral bandwidth:4nm1, 2, 4, 5nm Photometric range:0-125%t, -0.097-2.70a, 0-1999c, 0-1999f Photometric accuracy:¡à0.5%t Photometric reproducibility: 0.2%t Stray light: ¡ü0.3%t (ƛ 340, 420nm) ¡ü0.2%t (ƛ 340, 420nm) ¡ü0.15%t(ƛ 340, 420nm) Baseline flatness:/¡à0.005a Stability:¡ü0.004a/1hr/500nm (after 30min warm up) Power:220v 50hz Display:Lcd(2x20) Light source:Tungsten-halogen lamp Data output:Rs-232c Analysis software:SupportWith Dimensions:440x370x200mm Weight:17kg Standard export packing
Light source lamp: preset germany heraeus deuterium lamp / osram long life halogen tungsten lamp Uv1800 / uv1800pc specifications: Photometric methods: transmittance, absorbance, energy, reflectivity Wavelength range: 190nm-1100nm Special bandwidth: 2nm Stray light: ¡ü0.05%t (220nm, 360nm) Wavelength accuracy: ¡ü¡à0.4nm Wavelength reproducibility: ¡ü0.2nm Photometric range: -3a ~ 3a Photometric accuracy: ¡ü¡à0.3%t (0-100%t) ¡ü¡à0.002a (0-0.5a) ¡ü¡à0.004a (0.5-1a) Photometric reproducibility: ¡ü0.001a (0-0.5a) ¡ü0.002a (0.5-1a) Stability: ¡ü ¡à0.001a/h Noise: ¡ü ¡à0.001a Baseline flatness: ¡ü ¡à0.0015a Power: 100-240v, 50/60hz Light source: deuterium & tungsten-halogen lamp Accessories: Uv1800 spectrophotometer 1 set Power cable 1 pc Operation manual 1 pc Certificate of quality checking 1 pc Fuses (2 a) 2 pcs 10mm quartz cuvettes 2 cases Packing list 2 pcs Compact disc 1 pc (uv1800pc only) Rs-232 cable 1 pc (uv1800pc only) Dust cover 1 pc Software specifications: 1. Such operation as photometric measurement, spectrum measurement, quantitative measurement, kinetic measurement are offered in uvcon windows applications. 2. Single-wavelength quantitative measurement can be measured with several kinds of arithmetic calculation methods to meet users¡¯ demand. 3. Curves can be measured and recalled in memory with data-handling of arithmetic calculation smooth, abs to/ from %t conversion and peak pick. 4. The measured data and graphics can be stored on pc/ printed/ output for reports. Outstanding quality, keeping constant improving Standard export packing
Um lamp / osram long life halogen tungsten lamp Uv1901 / uv1901pc specifications: Photometric methods: transmittance, absorbance, energy, reflectivity Wavelength range: 190nm-1100nm Special bandwidth: 1nm Stray light: ¡ü0.03%t (220nm, 360nm) Wavelength accuracy: ¡ü¡à0.3nm Wavelength reproducibility: ¡ü0.1nm Photometric range: -4a ~ 4a Photometric accuracy: ¡ü¡à0.3%t (0-100%t) ¡ü¡à0.002a (0-0.5a) ¡ü¡à0.004a (0.5-1a) Photometric reproducibility: ¡ü0.001a (0-0.5a) ¡ü0.002a (0.5-1a) Stability: ¡ü ¡à0.004a/h Noise: ¡ü ¡à0.003a Baseline flatness: ¡ü ¡à0.0008a Power: 100-240v, 50/60hz Light source: deuterium & tungsten-halogen lamp Accessories: Uv1900 series spectrophotometer 1 set Power cable 1 pc Operation manual 1 pc Certificate of quality checking 1 pc Fuses (2 a) 2 pcs 10mm quartz cuvettes 2 cases Packing list 2 pcs Compact disc 1 pc (uv1901pc & uv1902pc only) Rs-232 cable 1 pc (uv1901pc & uv1902pc only) Dust cover 1 pc Software specifications: 1. Such operation as photometric measurement, spectrum measurement, quantitative measurement, kinetic measurement are offered in uvcon windows applications. 2. Single and multi-wavelength quantitative measurement can be measured with several kinds of arithmetic calculation methods to meet users¡¯ demand. 3. Curves can be measured and recalled in memory with data-handling of arithmetic calculation smooth, abs to/ from %t conversion and peak pick. 4. The measured data and graphics can be stored on pc/ printed/ output for reports. Outstanding quality, keeping constant improving Standard export packing
Functions: It can measure pH,mV(ORP) and temperature. LCD display, English operation system Automatic and manual temperature compensation, self-calibration, and self-calculation of electrode percentage theoretical slope Five types of pH buffer solution can be chosen to conduct automatic calibration (one point or two points) Test results can be stored, deleted, viewed and printed. The amount of data can reach the maximum of 200 sets. It has RS-232 interface, and it can be connected to TP-16 printer. Also, the interface can be used to connect data collecting software and computer. It can be used to measure pH value of ultrapure water, pure water and boiling water by adjusting equipotential point and choosing specific electrode. It is equipped with E-201-C pH combined electrode and T-818-B-6 temperature electrode. Specifications: 1.Measuring range pH£º(0.000~14.000)pH mV£º(-1999.9~1999.9)mV Temperature: (-5.0~105.0)¡æ 2.Resolution pH£º0.1pH¡¢0.01pH¡¢0.001pH mV£º0.1mV Temperature: 0.1¡æ 3.Accuracy: pH£º¡À0.005pH¡À1 bit mV£º¡À0.2mV (¡À399.9mV) ¡À0.03% FS Temperature:¡À0.3¡æ¡À1 bit 4.Input impedance>=3¡Á1012¦¸ 5.Stability:£¨¡À0.005pH¡À1bit£©/3h 6.Temperature compensation range: Manual/Automatic(-5.0¡«105.0)¡æ 7.Power supply: DC power (9V DC£¬300mA£¬inside positive and outside negative) 8.Dimension(mm)£º280¡Á210¡Á90 9.Weight: 1kg 340*270*280mm/unit 2.5kg
Functions: It can measure pH,mV(ORP) and temperature. The instrument is equipped with large LCD Touch Screen and English operation system for easy use. Several kinds of pH buffer solution can be chosen for instrument calibration. Furthermore, the buffer solution can be prepared by users. The instrument can recognize five types of buffer solution automatically. It has many functions such as automatic and manual temperature compensation, self-calibration and self-calculation of electrode percentage theoretical slope. The data can be stored, deleted, printed and viewed, and the quantity of measuring data can be maximized to 200 sets. It has standard RS-232 and USB interface. To match with data collecting software, it can be communicated with computer. It is equipped with E-201-D pH combined electrode and T-820C temperature electrode. Specifications: 1¡¢Measuring range pH£º£¨-2.000~18.000£©pH mV£º£¨-1999.99~1999.99£©mV Temperature: £¨-5.0~105.0£©¡æ 2¡¢Resolution pH£º0.1 pH ¡¢ 0.01 pH ¡¢0.001pH mV£º0.1mV ¡¢ 0.01mV Temperature: 0.1¡æ 3¡¢Accuracy: pH£º¡À0.002pH¡À1 bit mV£º¡À0.03% FS Temperature: ¡À0.2¡æ¡À1 bit 4¡¢Input impedance>=3¡Á1012¦¸ 5¡¢Stability: £¨¡À0.002pH ¡À1 bit£©/3h 6¡¢Temperature compensation range: manual/automatic £¨-5.0¡«105.0£©¡æ 7¡¢Power supply: AC (220V¡À22) V£»(50Hz¡À1)Hz 8¡¢Dimension£¨mm£©£º250¡Á195¡Á100 9¡¢Weight:2kg 370*310*340mm/unit 4kg
1. Static hydraulic four-wheel drive; 2. Automatic Shift of high and low moving speed; 3. Two working modes including moving and operation; 4. Three turning modes including front wheel turning, full wheels turning and crab turning; 5. Convenient connection devices for working appliances make working appliances replaced faster; 6. Multi-purpose operation handle: only one handle completes all operations; 7. Hydraulic-driven cooling system: the water tank & motor are disposed respectively to avoid bigger space requirement when they are disposed together, which makes the water temperature of the motor keep at the optimal level. 8. Lognitudinal stability indicating system and rollover protection system enhance operation safety; 9. ROPS/FOPS cab has the ability to protect drivers safety.
It works with four-wheel drive, hydromechanical transmission, hydraulic power steering, hydraulic brake, and rear-wheel steering. The handling equipment is telescopic boom, standard model installs moving fork. Besides smooth joystick controls and a wide range of attachments, we also can offer the right machine meet your specific requirements. Shovel loader, derrick boom and hook for selecting to install
With CE and ISO13485 marks This system was made up by the S350 Tower style Slit Lamps (5 magnifications)combining with the following accessories: Digital Camera Adaptor, Beam Splitter, Digital Camera, and BacLite Background Illumination Model(3V). Besides observing the eye diseases, it can take pictures, store and print the image. This is convenient to observe the patients' condition and evaluate the remedial effect. The high resolution ink jet printer, the image can be printed clearly. This system adopts the professional digital single lens reflex camera. 22.2x14.8 mm APS-C sensor Special Digital Camera Adaptor Image dimension: 4272 x 2848(max) 12.2 mega pixels Supported format: RAW, JPEG Shooting mode: single, shoot continually (every 3.5 second), self-timer, electric view and quick response remote control. Mechanical and CCD shutter Maximum shutter: 1/8000 second Minimum shutter: 30 second BacLite Background Illumination Model It can improve the effective shooting area, the picture will be more clear and bright. Triple Wall Corrugate Fibreboard Boxes Gross Weight: 26KGS Net Weight: 25KGS Dimensions: 740mm X 450mm X 500mm
With CE and ISO13485 marks Features: This system was made up by the S350 DC and the MediView software which is developed by MediWorks. Besides the digital camera functions of the S350 DC, the MediView software can transfer the images to the computer, and then do the image capture, classification, analysis, archive and generate diagnosis report. MediView has the advantages of clear interface and easy operation, which is convenient to establish the case archives. The system can store all the case description thus the case report output is easy to operate. Real time preview, single picture capture and image lead-in are supported. Specifications: Microscope Type: Galilean optic system Configuration: Haag-streit type Eyepiece: 12.5x Angle between eyepieces: 13 degree binocular tube with converging optics Magnification change: 5 steps by revolving drum Total magnification and field of view (mm):6X (34.7), 10X (22), 16X (13.5), 25X (8.5), 40X (5.5) Pupilary adjustment: 55mm~78.5mm Diopter adjustment: -6d~+6d Slit illumination Slit width: Continuous from 14mm to 0mm (at 14mm, slit becomes a circle) Slit length: Continuous from 14mm to 1mm (at 14mm, slit becomes a circle) Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal) Aperture diameters: 14mm, 10mm, 5mm, 3mm, 2mm, 1mm, 0.2mm Filter: Thermal safety, UV, Cobalt Blue, Red-Free Slit inclination 4 steps: 5 degree, 10 degree, 15 degree, 20 degree Lamp: German imported 6v, 20w halogen lamp (OSRAM) or LED lamp. Accessories: Applanation Tonometer Adaptor, Beam Splitter, DC Adaptor, DC, BacLite Background Illumination Model, MediView Image Capture System software etc... Yellow Filter, Amber Filter and Measuring Eyepiece are available Triple wall corrugated fibreboard boxes Gross Weight: 26KGS Net Weight: 25KGS Dimensions: 740mm X 450mm X 500mm
Slit Lamp Image Capture System (Video) With CE and ISO13485 marks Features: This PRI system was upgraded by the S350 Slit Lamps with the CCD Adaptor, Beam Splitter and CCD with high speed and resolution. Besides the functions of the S350 Slit Lamps it also has the following functions: 1) 5.0 mega high-definition static image capture. 2) Easy operated patients' information management, diagnosis report can be edited. Microscope Type: Galilean optic system Configuration: Haag-streit type Eyepiece: 12.5x Angle between eyepieces: 13 degree binocular tube with converging optics Magnification change: 5 steps by revolving drum Total magnification and field of view (mm):6X (34.7), 10X (22), 16X (13.5), 25X (8.5), 40 X (5.5) Pupilary adjustment: 55mm~78.5mm Diopter adjustment: -6d~+6d Slit illumination Slit width: Continuous from 14mm to 0mm (at 14mm, slit becomes a circle) Slit length: Continuous from 14mm to 1mm (at 14mm, slit becomes a circle) Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal) Aperture diameters: 14mm, 10mm, 5mm, 3mm, 2mm, 1mm, 0.2mm Filter: Thermal safety, UV, Cobalt Blue, Red-Free Slit inclination 4 steps: 5 degree, 10 degree, 15 degree, 20 degree Lamp: German imported 6v, 20w halogen lamp (OSRAM) or LED lamp. Accessories: Applanation Tonometer Adaptor, Beam Splitter, Video Adaptor, Video, BacLite Background Illumination Model, MediView Image Capture System software etcí¡ Yellow Filter, Amber Filter and Measuring Eyepiece are available Triple wall corrugated fibreboard boxes Gross Weight: 26KGS Net Weight: 25KGS Dimensions: 740mm X 450mm X 500mm
Incubator Offering laboratory instruments including co2 incubator, biochemistry incubator, mould incubator, light incubator (germinate), constant temperature incubator, centrifuge etc.
LMS-6000 High precision portable spectroradiometer lux meter and chroma color meter for led lighting products measurement 1. Spectral platform: telephoto asymmetrical crossed CT system. 2. Wavelength range: 380~780nm(300~950nm), FWHM: 2nm, Spectral resolution: 0.2nm 3. Sensor: CCD with 3648pix 4. Integration time: 50μs~20000ms 5. Stray light:
Composed of imaging cameras and image processor, binocular vision system can be installed on unmanned systems such as robot, UAV and AGV, improving their capabilities in aspects of environmental sense, visual distance measurement, obstacle detection, wire detection, obstacle avoidance, direction optimization, terrain following, intelligent tracking, light stream positioning and etc.
29 parts with inner organs. Size:66*37*173cm
Textile testing instruments, laboratory testing instrument like textile fabric testing instruments, mask protective clothing testing equipments, textile fabric abrasion tester, accelerated weathering tester, corrosion chamber.Manufacturer
Smart Wifi Remote Air Conditioning By 3g,4g, Wifi, Smartphone Control.
Human anatomical model, human skeleton model, human torso model, biological models, botany models, animal anatomical model, medical training simulators, nursing simulators.
Laboratory instruments, such as shaking incubator, clean bench, water bath, incubator, oven, shaker, biological safety cabinet.