The Canine Parvo Virus Antigen Rapid Test is a lateral flow immunochromatographic assay for the qualitative detection of canine Parvo virus antigen (CPV Ag) in dogs feces or vomit specimen. Assay Time: 5-10 minutes The Canine Parvo Virus Antigen Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into the sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated monoclonal antibodies. If there is CPV antigen in the specimen, a visible T line will appear. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of Parvo virus antigen in the specimen. REAGENTS AND MATERIALS -Test devices, with disposable droppers -Assay buffer -Cotton swabs -Products Manual STORAGE AND STABILITY The kit can be stored at room temperature (4-30C). The test kit is stable through the expiration date marked on the package label. DO NOT FREEZE. Do not store the test kit in direct sunlight. TEST PROCEDURE -Collect dogs fresh feces or vomit with the cotton swab from dogs anus or from the ground. -Insert the swab into the provided assay buffer tube. Agitates it to get efficient sample extraction. -Take out the test device from the foil pouch and place it horizontally. -Suck the treated sample extraction from the assay buffer tube and place 3 drops into the sample hole â??Sâ?? of the test device. -Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. INTERPRETATION OF RESULTS -Positive (+): The presence of both â??Câ?? line and zone â??Tâ?? line, no matter T line is clear or vague. -Negative (-): Only clear C line appear. No T line. -Invalid: No colored line appears in C zone. No matter if T line appears. PRECAUTIONS -All reagents must be at room temperature before running the assay. -Do not remove test cassette from its pouch until immediately before use. -Do not use the test beyond its expiration date. -The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. -All specimens are of potential infection. It must be strictly treated according to the rules and regulations by local states. LIMITATION Canine Parvo Virus Antigen Rapid Test is for in vitro veterinary diagnosis use only. All result should be considered with other clinical information available with veterinarian. It is suggested to apply a further confirmative method when positive result was observed.
The Canine Parvo Virus Antigen Rapid Test is a lateral flow immunochromatographic assay for the qualitative detection of canine Parvo virus antigen (CPV Ag) in dogâ??s feces or vomit specimen. Assay Time: 5-10 minutes The Canine Parvo Virus Antigen Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into the sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated monoclonal antibodies. If there is CPV antigen in the specimen, a visible T line will appear. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of Parvo virus antigen in the specimen. REAGENTS AND MATERIALS -Test devices, with disposable droppers -Assay buffer -Cotton swabs -Products Manual STORAGE AND STABILITY The kit can be stored at room temperature (4-30�°C). The test kit is stable through the expiration date marked on the package label. DO NOT FREEZE. Do not store the test kit in direct sunlight. TEST PROCEDURE -Collect dogâ??s fresh feces or vomit with the cotton swab from dogâ??s anus or from the ground. -Insert the swab into the provided assay buffer tube. Agitates it to get efficient sample extraction. -Take out the test device from the foil pouch and place it horizontally. -Suck the treated sample extraction from the assay buffer tube and place 3 drops into the sample hole â??Sâ?? of the test device. -Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. INTERPRETATION OF RESULTS -Positive (+): The presence of both â??Câ?? line and zone â??Tâ?? line, no matter T line is clear or vague. -Negative (-): Only clear C line appear. No T line. -Invalid: No colored line appears in C zone. No matter if T line appears. PRECAUTIONS -All reagents must be at room temperature before running the assay. -Do not remove test cassette from its pouch until immediately before use. -Do not use the test beyond its expiration date. -The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. -All specimens are of potential infection. It must be strictly treated according to the rules and regulations by local states. LIMITATION Canine Parvo Virus Antigen Rapid Test is for in vitro veterinary diagnosis use only. All result should be considered with other clinical information available with veterinarian. It is suggested to apply a further confirmative method when positive result was observed.
Beam-based Ceiling Supply Unit: 1. Beam length can be customized from 2000 to 3000mm. 2. The power supply and gas ports can be integrated in the carrier or installed on the beam. 3. The ICU ceiling supply unit is horizontally moveable, with separate wet zone and dry zone. 4. It offers a high load capacity for various medical devices. 5. Functional expansion is very convenient. 6. The ceiling supply unit is space efficient. 7. It is applicable to multi-bed ICUs. Combination Type Ceiling Supply Unit: 1. The ICU ceiling supply unit offers a high load capacity for various medical devices. 2. It allows convenient functional expansion. 3. Twin-axis rotatable arm design for separate wet zone and dry zone helps ensure safety. 4. The position for wet zone and dry zone is mutually exchangeable. 5. Optional dual arms for either zone are available for more space and flexibility. 6. The ceiling supply unit is suitable for special ICUs. Application The modular design of ICU ceiling supply unit can be tailored to suite any care areas requirements, from surgical, endoscopic, anesthesia and diagnostics applications as well as intensive care units.
laptop type ultrasound trolley ultrasound 4D color Doppler cheap black/white ultrasound machine wireless ultrasound probe could use with phone and tablet
Infinite positioning of the legs. Easily adjustable with pneumatic support Knee crutch is adapted automatically when the leg position is adjusted. One-hand operation. Pressure relief of the calves thanks to soft padded insert. Protects from positioning injury in the vicinity of the nervus peroneus.
Electrode, ECG, 21mmx40mm, Pediatric, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
Our Technology Advantages AFT Technology Adopt a multi-spectrum pulsed light which filters out the wavelength above 950nm to keep much water in the target skin so that the treatment is painless. EDF Technology To make sure the energy of every shot and pulse is the same and stable to keep safe treatment. In-montion Operation To shorten the time of treatment session, Accelerate the operation, save 1/2 treatment time Painless 1. Specific wavelength keeps much water in the target skin 2. EDF (Equally Distributed Fluence) ensures the uniform of energy Self-checking & monitor Monitor water circulation and identified handpiece to keep safe working Charging-Monitor Ensure the capacitors charging energy correctly Identified Handpiece Ensure safety Automatical Calibrate Constant and accurate energy output Application It could be used for hair removal and improving skin conditions. Besides, it can be used for all kinds of skin blemishes and skin diseases. Hair Removal Such as armpit hair, beard, lip hair, hairline, bikini hair, body hair Skin Rejuvenation Skin whitening, minimize pores, repair rough skin, enhance skin elasticity, smooth tiny wrinkles, eliminate and fade acne scars Pimples Acne, allergic acne, crusted acne Specifications Model S6 Light Source Pure Sapphire Spot Size SHR: 15*50mm SSR 8*40mm Wavelength 420-950nm for SAC(Optional), 570-950nm for SSR(Skin Rejuvenation), 650-950nm for SHR(Hair Removal) Power 220V/50Hz, 110V/60Hz Xenon Lamp Imported Lamp Fluence 1-7J/cm2 for SHR, 1-12J/cm2 for SSR(SAC, Optional) Timer 1s, 3s and 30s for SHR 1s, 2s, 12s for SSR(SAC, Optional) Frequency 3Hz for SHR, 2Hz for SSR(SAC, Optional) Intergrated Cooling 1-4 Degree Display 10.4" Colorful Touch Screen Calibrating Machine Automatic Calibrated Water Cooling Circulated Monitored In-scene Working Environment Indoor Use Only 35KG
Our Technology Advantages AFT Technology Adopt a multi-spectrum pulsed light which filters out the wavelength above 950nm to keep much water in the target skin so that the treatment is painless. EDF Technology To make sure the energy of every shot and pulse is the same and stable to keep safe treatment. In-montion Operation To shorten the time of treatment session, Accelerate the operation, save 1/2 treatment time Painless 1. Specific wavelength keeps much water in the target skin 2. EDF (Equally Distributed Fluence) ensures the uniform of energy Self-checking & monitor Monitor water circulation and identified handpiece to keep safe working Charging-Monitor Ensure the capacitors charging energy correctly Identified Handpiece Ensure safety Automatical Calibrate Constant and accurate energy output Application It could be used for hair removal and improving skin conditions. Besides, it can be used for all kinds of skin blemishes and skin diseases. Hair Removal Such as armpit hair, beard, lip hair, hairline, bikini hair, body hair Skin Rejuvenation Skin whitening, minimize pores, repair rough skin, enhance skin elasticity, smooth tiny wrinkles, eliminate and fade acne scars Pimples Acne, allergic acne, crusted acne Specifications Model G80 Light Source Pure Sapphire Spot Size SHR: 8*40mm SSR 8*40mm (Optional) Wavelength 650-950nm for SHR(Hair Removal) 420-950nm for SAC(Optional), 570-950nm for SSR(Optional), Power 220V/50Hz, 110V/60Hz Xenon Lamp Imported Lamp Fluence 1-7J/cm2 for SHR, 1-12J/cm2 for SSR(SAC, Optional) Timer 1s, 3s and 30s for SHR 1s, 2s, 12s for SSR(SAC, Optional) Frequency 2Hz for SHR, 2Hz for SSR(SAC, Optional) Intergrated Cooling 1-4 Degree Display 8.4" Colorful Touch Screen Calibrating Machine Automatic Calibrated Water Cooling Circulated Monitored In-scene Working Environment Indoor Use Only 20KG
Our Technology Advantages AFT Technology Adopt a multi-spectrum pulsed light which filters out the wavelength above 950nm to keep much water in the target skin so that the treatment is painless. EDF Technology To make sure the energy of every shot and pulse is the same and stable to keep safe treatment. In-montion Operation To shorten the time of treatment session, Accelerate the operation, save 1/2 treatment time Painless 1. Specific wavelength keeps much water in the target skin 2. EDF (Equally Distributed Fluence) ensures the uniform of energy Self-checking & monitor Monitor water circulation and identified handpiece to keep safe working Charging-Monitor Ensure the capacitors charging energy correctly Identified Handpiece Ensure safety Automatical Calibrate Constant and accurate energy output Application It could be used for hair removal and improving skin conditions. Besides, it can be used for all kinds of skin blemishes and skin diseases. Hair Removal Such as armpit hair, beard, lip hair, hairline, bikini hair, body hair Skin Rejuvenation Skin whitening, minimize pores, repair rough skin, enhance skin elasticity, smooth tiny wrinkles, eliminate and fade acne scars Pimples Acne, allergic acne, crusted acne Specifications Model AFT-600 Light Source Pure Sapphire Spot Size SHR: 15*50mm SSR 8*40mm Wavelength 420-950nm for SAC(Optional), 570-950nm for SSR(Skin Rejuvenation), 650-950nm for SHR(Hair Removal) Power 220V/50Hz, 110V/60Hz Xenon Lamp Imported Lamp Fluence 1-7J/cm2 for SHR, 1-12J/cm2 for SSR, (SAC, Optional) Timer 1s, 3s and 30s for SHR 1s, 2s, 12s for SSR (SAC, Optional) Frequency 3Hz for SHR, 2Hz for SSR, (SAC, Optional) Intergrated Cooling 1-4 Degree Display 12.1" Colorful Touch Screen Calibrating Machine Automatic Calibrated Water Cooling Circulated Monitored In-scene Working Environment Indoor Use Only 141*70*55cm3 65KG
Our Advantages Germany Osram LED Lamps: The best quality lamp to ensure effective energy and longer life span SMD LED: To ensure good heat-dissipation and high energy tranfer rate Interchangeable Treatment Heads: One machine with several heads to make sure the effectiveness and cover all the applications Intelligent Treatment Heads: Identified by the machine to ensure total safety and simplify work Two Operation Modes: 1. Simple Mode: Easy for beginners to operate 2. Expert Mode: Useful for clinics, can save programs in advance to save time and simplify work 10.4'' colorful touch screen: Easy to operate Multiple Languages: Can be used by people from any country Articulated Arm: Revolve 360 degree, convenient to adjust the position of the treatment head Adjustable 5 PCB Panels: Convenient to adjust the shape of treatment head according to target place Application Blue Light 469nm Acne, Pimples, Inflammation of the Skin Therapy, Comedones Improved Red Light 633nm Anti-aging, Reduce Fine Lines & Wrinkles, Improve Skin Texture, Clear Photo Damaged Skin, Skin Repair Infrared Light 850nm Improve Micro-circulation and metabolism, can be used with Blue or Red light to deliver better treating results Yellow Light 595nm Help the lymph system to detoxify your body Green Light 530nm Reduce pigmentation through penetration into base skin layers, Prevent the forming of fleck, Keep skin smooth and bright 70*77*117cm3 35KG
Bandage.
X ray baggage scanner, handheld metal detector, walk through metal detector, liquid detector, explosives detector , under vehicle surveillance.
Surgical instruments.
Orthopedic equipments & implants.
Covid 19 rapid home test kits.
Water chiller machine for ice bath , smart controller for hbot, hyperbaric oxygen chamber , other smart , intelligent health care devices.
Rapid test kits.
Multiplex One Step RT-qPCR Probe Kit is a multiplex quantitative PCR kit based on RNA as template. In the process of the experiment, reverse transcription and quantitative PCR were carried out in the same tube, which simplified the experimental operation and reduced the risk of contamination. In this kit, the first strand cDNA was efficiently synthesized by heat-resistant Hifair V reverse transcriptase and quantitatively amplified by UNICON HotStart Taq DNA polymerase. The kit mainly contains optimized MP buffer, enzymes mix, etc. The buffer solution already contains Mg2+ and dNTP. In addition, the factors that can effectively inhibit the non-specific PCR amplification and improve the amplification efficiency of multiple qPCR reactions are added, which can ensure the amplification efficiency and carry out up to four reactions. Quantity: 100 T, 1000 T, 10000 T Applications: RT-qPCR, 4-plex reaction Sample Type: RNA template main enzyme: Hifair V Reverse Transcriptase,UNICON HotStart Taq DNA Polymerase Category: IVD PCR Research Area: RT-qPCR
Ultra fast pcr, innovative molecular testing pcr on chip semiconductor chip pcr. while you wait molecular testing. 5mints 40 amplifications.
Our products are directly from factories, Boson, H-Guard, Flow flex, etc.