I. Introduction SS-300-HF Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for online monitoring of organic waste gas emissions and organic waste gas recovery for chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductors, synthetic leather and so on. III. Specifications Monitoring place Gas component Measurement range aluminum oxide outlet HF 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: ,¸8,?6 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load550Ω 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190â??, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. 9.With lens blow up function, to prevent it dewing.
I. Introduction SS-300-HCL Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for stack outlet in the waste incineration power plant. III. Specifications Monitoring place Gas component Measurement range Waste incineration stack outlet HCL 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: 86 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load4 - 20mA 550© 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. With lens blow up function, to prevent it dewing.
I. Introduction SS-300-NH3 Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used to monitor NH3 after SNR or SCNR process in the waste incineration plant, power plant and so on. III. Specifications Monitoring place Gas component Measurement range SNR or SCNR stack outlet NH3 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: ø8Ã?6 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load4 - 20mA 550© 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. 9.With lens blow up function, to prevent it dewing.
I. Introduction The SS-700 process VOCs monitoring system is based on the standards of HJ/T80, HJ/T75, HJ/T76 and other related standards, sampling by extraction method, configuration based on advanced gas chromatography, mass spectrometry separation technologies and hydrogen flame Ionization Detectors (FID), photoionization detectors (PID) to measure the composition of volatile organic gases such as total hydrocarbons (THC), non-methane total hydrocarbons (NMHC), aromatic hydrocarbons, esters, etc. According to the composition and detection requirements in the analysis project, it can be configured to meet the requirements of the analysis project and the frequency of analysis. At the same time, the optimization of instrument configuration can be performed to maximize the use of the instrument and ensure the continuity of sample analysis. reliability. The analysis system fully considers sample gas conditions, dew point and other factors, and specifically designs the pretreatment system to prevent the crystallization of components in sample gas from condensing and changing the concentration of components. The instrument uses special column combination, center cutting and back blowing technology and hydrogen flame ionization detector (FID) technology for detection. The FID Hydrogen Flame Ionization Detector is a typical mass detector that measures the mass change rate of a component in a GC gas. The response value is proportional to the mass of a component entering the detector per unit of time. II. Features 1.The system piping is imported clean stainless steel pipe to reduce adsorption; 2.The system adopts full calibration to eliminate the influence of a small amount of adsorption on the measurement. 3.The analytical method is consistent with the calibration method, and it is detected by GC-FID method. 4.The whole process of high-temperature 180 °C with hot sample transmission, high temperature FID detection, to avoid high-boiling VOCs adsorption and condensation, more accurate measurement; 5.Continuously run maintenance-free design, start-up automatic cycle operation, real online analysis; 6.The whole flow path insulation design is 180°C, no water vapor condensation, to avoid corrosion degradation of parts, suitable for high temperature / high humidity / corrosive conditions; 7.Non-methane total hydrocarbons and simultaneous monitoring of benzene, toluene, xylene and other components III. Application fields It is used for on-line monitoring of organized organic waste gas emissions from chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductor, synthetic leather, organic waste gas recovery.
I. Introduction SS-2000-HG mercury emission monitoring system for flue gas is a combination of the world's advanced online analytical technology and China's environmental protection monitoring technology. It is based on the company's many years of accumulated experience in the field of gas analysis and adopts multi optical path UV atomic absorption method. The system consists of a sampling unit with heat trace, a valence converter, and an analysis and processing unit. It can realize continuous on-line automatic and accurate measurement of mercury from fixed sources of flue gas. The system uses Cold Vapor Atomic Absorption Spectrometry (CVAAS), which is the most mature and stable analytical method among many mercury analysis methods. This method can only analyze the elemental mercury (Hg0) in the vapor state. CVAAS is based on the principle of selective absorption of ultraviolet light with a wavelength of 253.7 nm using mercury vapor. The low-pressure mercury lamp emits ultraviolet light through a gas chamber filled with sample gas and directly monitors the transmitted light intensity with an optoelectronic receiver to calculate the absorbance. Within a certain concentration range, the mercury concentration is proportional to the absorbance, which is in accordance with Beer-Lambert law. At the same time, oxygen, temperature, pressure, flow rate, humidity and other parameters can be monitored. Charts are generated through the data acquisition and processing system, and data remote transmission interfaces are reserved. The monitoring data can be transmitted to all levels of environmental protection according to the HJ/T212 national standard communication protocol. department. II. Specifications 1. Detection method: Cold Vapor Atomic Absorption (CVAAS) 2. Measurement range: 0-100g/m3, 0-500g/m3 3, detection limit: 0.05g/m3 4, response time T90:
1. Introduction SPF223 sampling probe used in the systems for gas sampling, filtration and heating function, can effectively prevent the condensation of gas samples collected, unique structural design allows for a sampling system is more reliable, more small gas loss rate to ensure system stability and true 2. Features The device and the part of the sample contact are all made of 316L stainless steel material processing, high temperature resistance, strong corrosion resistance. With rain cover can do outdoor work environment. Adopting the isothermal heating body, in the design of compact structure, stable heating temperature. Filter element is made of sintering titanium alloy which has big filter area, high accuracy, small air lock, and can be replaced from the device pulled out completely, simple operation, without tools, greatly shorten the maintenance time, and reduce the labor intensity. Optionally providing a reusable purging / calibration port. Operation is simple, with low temperature alarm. The filter replacement without tools. The switch is convenient, with locked cover. High efficiency filter cleaning system. 3. Specifications Maximum sampling temperature: 300 Maximum working pressure: 6BAR Sampling chamber heating temperature: 140 (factory set, adjustable temperature) Power supply: 220VAC 50/60Hz max 500W Environment temperature: -20~80 Maximum dust load: 100g/m3 Filter accuracy: 5μm (other precision optional, 1-10 m) Filter size: 150*35mm Purging gas interface: OD8/6mm connector Sample gas outlet: OD8/6mm connector The sampling pipe containing: 25 * 1200mmlength is optional Flange size: DN65PN6 The installation of accessories: installation flange & fixing bolts & flange sealed pad
1. Introduction Sampling heated tube is one important part of the environment protection monitoring system, widely used for SCNR, SNR, waste incineration and other emission sampling. 2.Specifications Gas pipe material: PVDF, PTFE, 316L, PFA Black knit anti-scratch layer Air tube size: OD8/6mm,OD6/4mm (optional) Power consumption: 10-100W/M (depending on heating tempeature) Power supply: 220VAC 50HZ Sample gas heated temperature50~220 No breakpoint and cold point all the way Using temperature controller to control heating temperature precisely Excellent heat preservation effect Heated tube external diamete: OD38±2mmOD42±2mm Minimum bending: 0.5m Lowest working temperature: -20 Minimum installation distance: vertical 2m, horizonal 4m.
1. Introduction ECM1/2 series gas condenser is used in the sample gas pretreatment system to remove moisture from the sample. Precise measurement of gas composition means sample gas under dew point can be stable even under bad environment. ECM condenser is to improve measurement precision and life span. 2. Features Perfect design, only one component: compressor Two-loop system Two-loop heating exchanger Constant temperature adjusting system with patent With temperature display Temperature alarm Dew point stability: 0.2 Environment protection refrigeration without Freon 3. Specifications 1.Ambient Temp045 6.Dew point Temp4Factory set 2.Temp Control Accuracy±0.27.Power supply220VAC 50/60Hz 3.Gas Inlet Temp80 8.Voltage300V, fuse10A 4.Gas flow rate300L/h 9.IP gradeIP20 5Warming-up Time15 min 10.Installationwall mounted or 19?�rack
I. Introduction SS-UV-300 flue gas analyzer (low emission monitoring) based on years of experience in research and development of flue gas analyzer, combined with the field practice of nearly ten thousand successful application cases. A number of techniques of the flue gas analyzer (standard form) are upgraded (many times return room to increase gas absorption optical path, and higher accuracy of spectrometer, convection heat transfer core module temperature control, etc.). The analyzer is based on DOAS and chemometric algorithms (PLS), able to measure concentration of gases including SO2, NO2, NO, O2, NH3, Cl2, O3, H2S, CH3I, etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions. II. Application fields It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son. III. Specifications Model Standard Low Emission Ultra-low Emission Range 0-300-3000ppm 0-100-300ppm 0-20-100ppm Linearity ±1.5%F.S. Repeatability ±0.5%F.S. Zero Drift ±2%F.S/7d Span Drift ±2%F.S/7d Response time(T90) 10S 30S 30S Working Temp -10-+40 Preheating time No preheating Approx.10 min Sample Gas Interface 6 Sample Gas Flow 0.5-2L/minFluctuation
I. Introduction The analyzer is based on NDIR (Non-dispersive Infrared) technology able to measure concentration of gases including CO,CH4,CO2,SO2,NO etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions. II. Application fields It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son.
SMT spare parts X 8mm Dual Smart Feeder 00141269-03 for siemens smt pick and place machine SMT spare parts X 8mm Dual Smart Feeder Product Details: Siemens/ASM Siplace X 4mm feeder 00141268 Siemens/ASM Siplace X 8mm feeder 00141270 00141290 00141370 00141390 Siemens/ASM Siplace X 2x8mm feeder 00141269 00141289 Siemens/ASM Siplace X 12mm 00141271 00141291 00141371 00141391 Siemens/ASM Siplace X 16mm 00141272 00141292 00141372 00141392 Siemens/ASM Siplace X 24mm 00141273 00141293 Siemens/ASM Siplace X 32mm 00141274 00141294 Siemens/ASM Siplace X 44mm 00141275 00141295 Siemens/ASM Siplace X 56mm 00141276 00141296 Siemens/ASM Siplace X 72mm 00141277 00141297 Siemens/ASM Siplace X 88mm 00141278 00141298ABOUT US GOLDLAND ELECTRONIC TECHNOLOGY CO., LTD focus on global Surface Mount electronic assembly sector for 10 years. We mainly provide competitive price and high quality products for various brands of SMT equipments, SMT feeders, SMT nozzles, SMT feeder spare parts, AI equipments, AI spare parts and other related products. The brands is: FUJI, KEM, PANASERT, YAMAHA, JUKI, Hitachi, Universal, Siemens, I-pulse, Assembleon, DYNAPERT, TDK and so on
Explore is the newest generation hand held xrf analyzer, it is the best hand held XRF analyzer with many features that you cant find in the markets and other brands The features of Explores are as below: 1. Best SDD detector in the world:it equiped with the best SDD detector-fast SDD detector, that enable to analyze light elements directly without helium asist from Mg U 2. more powerful data library:it can test rare earth elements and enable to test 34 elements simultantaneously 3. more safety design, there is insurance lock key to gurantee the safety for operator and invoid mis operate 4. non power off design, the analyzer works 5 minutes even you take the battery off the analyzer, which offer you enough time to change battery and finish testing once the battery power off 5. 3 color light system: there are green, red and yellow light system to show you the working status of the analyzer 6. operator and expert mode system easy to switch 7, 3 seconds fast scan for metal alloy and stainless steel
Size (open) L110cm*W240cm*H44cm Equipped with drone self-stabilizing system Yes Equipped with runaway safeguard Yes Equipped with GPS system Yes Max. Speed 100 km/h Drone Payload 8KG Endurance time without load 22-23 mins Endurance time with load 15-18 mins Max. suspension stop time 30 mins Battery capacity 16000 mAh Battery life Charge/discharge 200-300 times Max. remote control distance 1 km Max. flying height 2 km Application Hanging powerlines,bridge ropeways Wind loading rate Level 6 Flying height 0-20m The function of electricity wire installing drone: 1. The drone has accurate GPS positioning, and precise to ±1m in landscape orientation, and ±0.5m in portrait; 2. When the drone canâ??t get the remote control signal, it will enter into automatic protection mode which will let it be in suspension stop immediately. When there is no signal more than 20 seconds, the drone will return and land at the take-off place based on the GPS navigation system; 3. You can control the drone fly to any direction you want, no matter which direction the head towards to at this moment; 4. Under the straight mode, the drone will fly forward in a straight line; 5. The drone, with the function to fix the place for going back, can return to the take-off point automatically after the task is finished; 6. With protection function for low voltage. Once the voltage is lower the preseted, the lights will flicker to remind. Advantages: 1. Made of carbon fiber material in aviation field, with reasonable design in aircraft and excellent performance in anti-impact; Foot stand is easy to retract; 2. Special design for high beam, and easy to be tracked; 3. With voltage indication function, more convenient for user; 4. Equipped with sealing motor, dustproof and waterproof; 5.Lifelong after-sale, more professional.
Size (open) L110cm*W240cm*H44cm Equipped with drone self-stabilizing system Yes Equipped with runaway safeguard Yes Equipped with GPS system Yes Max. Speed 100 km/h Drone Payload 8KG Endurance time without load 22-23 mins Endurance time with load 15-18 mins Max. suspension stop time 30 mins Battery capacity 16000 mAh Battery life Charge/discharge 200-300 times Max. remote control distance 1 km Max. flying height 2 km Application Hanging powerlines,bridge ropeways Wind loading rate Level 6 Flying height 0-20m The function of electricity wire installing drone: 1. The drone has accurate GPS positioning, and precise to ±1m in landscape orientation, and ±0.5m in portrait; 2. When the drone canâ??t get the remote control signal, it will enter into automatic protection mode which will let it be in suspension stop immediately. When there is no signal more than 20 seconds, the drone will return and land at the take-off place based on the GPS navigation system; 3. You can control the drone fly to any direction you want, no matter which direction the head towards to at this moment; 4. Under the straight mode, the drone will fly forward in a straight line; 5. The drone, with the function to fix the place for going back, can return to the take-off point automatically after the task is finished; 6. With protection function for low voltage. Once the voltage is lower the preseted, the lights will flicker to remind. Advantages: 1. Made of carbon fiber material in aviation field, with reasonable design in aircraft and excellent performance in anti-impact; Foot stand is easy to retract; 2. Special design for high beam, and easy to be tracked; 3. With voltage indication function, more convenient for user; 4. Equipped with sealing motor, dustproof and waterproof; 5.Lifelong after-sale, more professional.
Model Name JSC-68S digital alcohol tester Display Red backlight 3-digit LCD screen Sensor semiconductor sensor Detection Range 0.000-0.190% BAC 0.000-0.995mg/L (BrAC) Alarm point 0.050% BAC 0.250mg/L (BrAC) Accuracy -0.01 to 0.02%BAC at 0.05%BAC Response Time -
Features * Nice appearance and innovative design * LED illuminator around lens * Imported lens with plated layer * 5.0 Mega pixels high resolution Korea sensor * Special DSP image processor, Optical Image Stabilizer * Single/Dual lamp control. * Single capture button and digital pause capture. * Adjustable focus to give clear image. * Auto white balance and contrast adjustment, Color Temperature Filter * Dual image compare function * 3D-Negative capture mode * Compatible with iris lens, hair lens and skin lens. * Deliver clear and accurate images. * Easy to operate. * Maximum resolution: 2560x1920
Product descriptions from the supplier Overview Metallurgical Microscope Specifications Model JX-203 Viewing Head Trinocular, Inclination of 30�° Eyepiece Wide field WF10X(�¦18mm) Objective Plan achromatic objectives with long working distance 5X/0.12, 10X/0.25, 40X/0.60, 60X/0.75 Focusing Coaxial coarse/fine focus system, with tensional adjustable and up stop, minimum division of fine focusing: 2�¼m Nosepiece Quadruple(Backward ball bearing inner locating) Stage Double layer mechanical (Size:185mmX140mm,movingrange:75mmX50mm) Illumination 6V 20W halogen lamp, brightness control
Product descriptions from the supplier Overview Specification: Scope holder: 83mm Vertical Post Height:305mm Vertical Post Dia.: 32mm Base Dimensions:320x305x16mm Coarse/Fine Focus Type: Coarse Focus Travel Distance:50mm Center Distance from the Hole to the Scope Holder: 150mm Net weight: 3.25kg (17.37lbs) Dimensions: 320x305x474mm
Product descriptions from the supplier Overview Metallurgical Microscope Specifications Model JX-200E Optical system Finite color corrected optical system Viewing head Gemel trinocular,45 °inclined,Diopter adjustment ±5 for each side,Interpupillary distance adjustable between:54-75mm,refract rate,binocular : trinocular =80%:20% Eyepiece High eyepoint wide field plan eyepiece PL10X/18mm High eyepoint wide field eyepiece WF15X/13 High eyepoint wide field eyepiece WF20X/10mm Objective LWD plan achromatic metallurgical objective 5X,10X,20X,50X,100X Nosepiece Reversed quadruple nosepiece Reversed quintuple nosepiece Focusing Low position coaxial coarse and fine adjustment. With tightness adjustment. Coarse adjustment range 38 mm;precision of fine adjustment:2um stage Three-ply mechanical stage,area 180mmX155mm,right hand low position control,Moving range:75mm 40mm; Metal stage plate,center hole dia.�?12mm Illumination Reflection Koehler illumination with iris diaphragm and center able field diaphragm , wide-range voltage 90-240V ,6V/30W halogen bulb(single 3W LED option), with continuous intensity Polarizing kit Polarizer and the analyzer can be removed from the optical path, the analyzer can be rotated 360 . Photo accessories Photo tube(with PK mount),photo eyepiece 3.2X Video accessories CTV0.5X/1.0X software specialized metallographic analysis software
TS - 30 s binocular continuous variable times a stered microscope Product description: TS - 30 s binocular continuous variable times a stered microscope using LED light source, high resolution, high resolution and strong stereo feeling, etc, and can get times continuously. Optical system about separate light path, towards a prism object into exactly, accord with human physiology habit. PLAN10X eyepiece is high eyespots wide-angle eyepiece, the entire field of view, wear glasses of workers are not subject to any restrictions. Perfect streamline design, modelling beautiful generous, excellent optical system and reliably operating structure, make the image more clear, more simple operation, and to bring you the new feeling. Widely used in teaching demonstration, dissection, the seeds of agroforestry inspection screening, * * department of forensic examination, electronic precision components assembly maintenance, textile quality control, auxiliary differential stamps and all kinds of material surface observation. Performance characteristics: 1, the continuous adjustable magnification 2, the LED light source, light is soft 3, modelling beautiful and easy, convenient operatio 4, separate light path, stereo sense is strong, clear imaging 5, using high eyespots wide-angle eyepiece, wide field of view, the field of flat. Microscope technology parameters