Applications: Used in kitchen,and can pocket by caps with different colors and it is easy to read. Case:Stainless Steel Dial and Pointer:Aluminum Stem:Stainless Steel Cap of thermometer:ABS Temperature range:0-60
Application Absolute pressure gauge use to watch or measure some vacuum equipments (for example:Vaccum packing machine,watch condensation pressure and liquid steam pressure equipment.) Which is absolute pressure gauge. Specification: Case Diameter:100mm Seals Diameter:160,100mm Ambience:-20~+60 Range:0-10/16/25/40/60/100kpa abs Accuracy:1.6
Brief Introduction Suitable for accurate measuring of the low pressure in vibrative locale. Technical specifications Execntive Standard:JB/T 9274 -1999 Instruments Diameter:100mm,160mm Accuracy Class:100mm.160mm 1.5%;(1.6%,2.5%) Range:6kpa-100kpa Protection Class:IP65 Ambient Temperature:-40â??~+60â?? Connection Thread:100/160 outer diameter M20 Instrument Case:SUS 304 stainless steel nature color Instrument socket:SUS316 nature color
Application: Media does not directly contact instrument's measuring system, Diaphragm sea does not raise a dead corner or area where residue may be left,universally used for sanitary applications. Model to European standard and various standards This kind of pressure gauge with clamp.
Application: Used for hydraulic and pneumatic systems Compressors,compressed air system Suitable for fluid medium which does not clog connection port or copper alloy Used for providing protection from vibration and pulsation. Case:Stainless Steel Ring:Stainless Steel Window:Safety Glass Socket & Connection:Brass Pointer and Dial:Aluminum Accuracy:1.6%
Application Used for hydraulic and pneumatic systems Compressors,compressed air system Suitable for fluid medium which does not clog connection port or copper alloy Used for providing protection from vibration and pulsation. Case:Stainless Steel Window:PC Socket & Connection:Brass Movement:Brass Pointer and Dial:Aluminum Accuracy:1.6%
Application: Media does not directly contact instrument's measuring system,diagragm sea does not raise a dead corner or area where residue may be left,universally used for sanitary applications. Model to European standard and various standards. DIN,SMS,IDF,RJT
Appication: Are used to meeasure pressure gauge difference,typical applications include filters,liquid tanks pumps and sterilizing chambers etc.
Application: Are used to measure pressure difference, typical applications include filters, liquid tanks pumps and sterilizing chambers etc.
Application: Suitable for low pressure measurement of high corrosive,vascous media. Qutside diameter:100,160 Accuracy:1.5%,2.5% Range:1kpa-2.5MPA Case& Internals material:Stainless Steel Diaphragm material:SUS304,SUS316,3J
Application: Media does not directly contact instrument's measuring system,Diaphragm sea does not raise a dead corner or area whenre residue may be left,universally used for sanitary applications. 63mm,98mm outside diameter Stainless Steel case and internals Accuracy:1%,1.5%
Caes:Brass Insert:Glass Thermowell:Brass Connection:1/2NPT Temperature range:-40-60-500
Blood Bank Refrigerator is professional refrigerator for storage blood bags(with whole blood) in blood banks,blood stations,hospitals,etc.Micro computer control,6 PT 100 temperature sensors to make sure the temperature control is 4 and the inside temperature is same as showed in the digital display.Select famous brand compressor,better temperature thermal effect raw materials,perfect air flow designing. It also can be used for storage high value pharmaceuticals,biological products,vaccines of which need special temperature controlled.
Vital signs Monitor (SpO2.PR.NIBP) 2.4" TFT screen , and blue LED digits. Small in size, and easy to carry High resolution color LCD for trend tabular and SPO2 waveform Compact and portable, allowing for uninterrupted monitoring with built-in battery High bright LED display of NIBP,SPO2 and pulse rate Manual, auto, continuous measurement of NIBP Adjustable audible and visual alarms Up to 2000 groups NIBP data storage and 65000 SpO2 data SpO2 data. Changeable probe (Adult, Infant ,Newborn) AC/DC power supply Options Printer (built-in)
Defibrillator type Manual, Synchronized, A synchr onized, Energy accuracy +1% Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule joule(nominal at a resistance of 50) Charging time Maximum 8 seconds to 360 Joules Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated) Output waveform: Monophonic technology Biphasic technology (Option)
Defibrillator type Manual, Synchronized, A synchronized, Output waveform Monophonic technology /Biphasic technology (optional) Energy accuracy +1% Energy selection 0 3 5 7 10 20,30 50,100,200,300,360 joule(nominal at a resistance of 50) Charging time Maximum 8 seconds to 360 Joules Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated) Power requirements. (a) AC Power supply 110V, 60 Hz /220V, 50 Hz (b) Vehicle Voltage DC 12V Internal Battery Backup Battery type Rechargeable lead-acid battery/ lithium battery (optional) Charging time Time-Minimum of 4 hours for full charging Battery charging During AC Power Supply operation of the device. Charging /Low Battery Indication Red LED Battery Capacity 100% of the battery will provide 120 min of monitoring; and 30 discharges at 360 joules.
Notebook Electronic Ultrasound Scanner 10.4 inch TFT color LCD Applicable to both human being and veterinary purposes 128 Frame storage Multi sectional dynamic focusing: Wide band pre-amplification, Log compression TGC control Dynamic filtering Edge enhancement and frame correlation
Single Channel ECG Complete digital and portable design Built-in rechargeable Li-ion battery, AC/DC power supply Auto/Manual work mode select-able Lead-off detection and display Complete digital filtering, resisting baseline drift, AC and EMG interference Baseline automatically adjustable to optimize printing position High-resolution thermal printing
Handheld Ultrasound scanner Monitor: 5.5 inch TFT color LCD Full digital beam forming technology Gama correction, histogram& Scanning angle adjustment Display Mode: B,B+B,4B,B+M,M image magnification: 1.0, 1.2, 1.5, 2.0 times 4 focusing combination selectable PAL-D output Gray Scale: 256 levels 256 frames for cine-memory,64 image permanent storage Image Procession: DFS, DRF, RDA, VGA/DSC and Image Post Procession 15 difference kinds of body marks with difference calipers. Measurement in Distance, Circumference/Area, Time/Heart Rate/EF rate for heart, and GS, CRL, BPD, HC, FL, AC for OB/GY measurement, and Gestational Age, Fetal weight, EDD calculation. Characteristic showing in real-time clock, ID, Sex, Age, Focusing Info and Gain (Near, Far, Overall) info. USB 2.0 For real-time picture uploading to PC Scanning Method: Convex, Micro-convex, Linear, rectal
Audible and visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting etc LCD Display, high capacity words, friendly user interface, dynamically display working status Compatible with 10ml, 20ml, 30ml, 50/60ml syringe of any brands Preset solution volume to greatly reduce the workload of nurses Three work modes: Rate mode, Time Volume mode, Dosage Weight mode Three levels of occlusion: high, medium and low Purge and Bolus function KVO (keep-vein-open) automatically opens as injection is completed, KVO rate is 1ml/h, also can be modified from 0.1ml/h to 10ml/h Freely Stackable: freely stack one syringe pump onto another to provide multiple solutions, which have a wide range of clinical applications. Connecting Port for Nurse-Paging Power Source: AC100-240V, 50/60Hz; Internal Battery, DC11.1V car charge One-key operation makes setup easy and simple Syringe Plunger Grabble Detector, operable with one hand in a No-Germ Environment Automatically record the settings for last infusion(MD910s have 2000 records) Drug library is available according to customers requestïMD910s