Scratch Grinding Tester Automobile line inspection equipment Wire and Cable Detection Equipment It is applicable for assessing the scratch-resistant performance of automobile wire insulation with external forces in line with the requirements of GB/T12528-2008. Main parameters: 1. The scratch grinding device exercises in two directions along wire axes with a stroke above 10mm 2. Exercise frequency: 50~60 cycles/min 3. Minimum distance between test points and test point and test sample end: >10mm; rotation angle of test sample: 90° 4. Length of test sample: Test sample which is about 750mm is firmly fixed to a steel anvil 5. Weight: 400, 700, 1000g (weights applied to scratching needle) 6. Function: The device will stop when the scratching needle grinds through insulation and comes into contact with conductor
Resistance Test Instrument Supplier ZY9733 and ZY9734 digital desk type low current resistance measuring meters are suitable for units concerned to measure the DC resistance of various components and parts with certain limitations on current, such as platinum resistor, coppery thermal resistor, PTC ceramics, thermistor and various wire rods, etc. 1. Key features 1.1 It adopts a large green LED to display measured value, which is striking and clear. It also adopts the four-terminal resistance measurement method to eliminate the impact of conductor resistance, and the measurement accuracy is high. 1.2 There are a variety of specifications, and each specification has four scales to meet the measurement requirements of different users. 1.3 The test current is lower than similar equipment, which effectively prevents the impact of components and parts on resistance. 1.4 ZY9734 type has a RS-232 serial data output interface to facilitate the connection to computer. 1.5 It adopts a novel plastic shell and can changes the inclined angle between the device and table by adjusting the handle position, so as to determine the suitable panel observation angle. It has a well-designed appearance and is easy to use. 2. Main technical indicators Temperature: Reference conditions: 20±5; nominal condition: 5~35 Relative humidity: Reference conditions: 40~60%; nominal condition: 25%~75% Power source: AC 220V±10%, 50Hz, power consumption: About 5VA.
KYN28A-12 (GZS1-12) Model Indoor AC Metal Clad Intermediate Switchgear,KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear,Circuit Breaker Switchgear,High and Low Voltage Switchgears,Indoor AC Switchgear Product Description KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear, this product is suitable for three phase AC power system with rated voltage 12KV and rated frequency 50Hz, is used for receiving and distributing the power energy, to control, protect and monitor the circuit. Product Features Meet the standard: GB3906-97 3-35KV AC Metal-enclosed Switchgear, GB11022-89 High-voltage Switchgear General Technical Conditions, IEC298 (1990) AC Metal-enclosed Switchgear and Control Equipment With Rated Voltage Above 1kv and or Below 50kv , DL404-97 Order Technical Conditions for Indoor AC High Voltage Switchgear Cabinet. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears GGD series low voltage switchgear is used for power lighting Product Description GGD series low voltage switchgear is used for power lighting, power transformation, distribution and control for AC distribution system with rated frequency 50HZ and rated operation voltage 380V, rated current up to 3150A at power plant, substation, mine enterprises and other users. It owns high breaking capability, rated short time withstand current can be up to 50KA, circuit layout is flexible and combination is convenient and so on. It is one of typical products for assembled type, fixed panel switchgear in domestic. This product complies with the national standards GB7251 Low-voltage Switchgear and Control Equipment, international standard IEC 60439 Low - voltage Switchgear and Control Equipment. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
XGN2 Type Modular High Voltage Switchgear,High Voltage Switchgear,High and Low Voltage Switchgears XGN2 type modular high-voltage switchgear cabinet is applied to receive and distribute the electrical energy in three-phase AC power system with rated voltage 3, 6, 10KV and rated frequency 50HZ Product Description XGN2 type modular high-voltage switchgear cabinet is applied to receive and distribute the electrical energy in three-phase AC power system with rated voltage 3, 6, 10KV and rated frequency 50HZ, especially for the frequently operated occasion. Its busbar system is a single busbar (which can derive the single busbar with bypass and double busbar structure). The switchgear cabinet is in line with the requirements of the National Standards GB3906 3-35KV AC Metal-enclosed Switchgear and the international Standard IEC298, also there are proposed "five anti" interlocking functions such as anti-breaking and closing by mistaken for circuit breaker, anti-breaking and closing disconnector switch with load, anti-breaking and closing grounding wire/switch with load, anti closing circuit breaker/disconnector switch with grounding wire/switch, anti entering charged interval by mistaken. Product Features The main switch of the switchgear applies ZN28A-10 series vacuum circuit breakers, equipped with CD117 series of electromagnetic operating mechanism and CT19 series of spring operating mechanism. Using GN-30 rotary isolating switch. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Gck low-voltage draw out switchgear, low voltage switchgear, draw out switchgear, circuit breaker switchgear High and low voltage switchgears Gck series low voltage draw out switchgear is applicable for three phase four wire/five wire ac power system with rated operation voltage 380v Product description Gck series low voltage draw out switchgear is applicable for three phase four wire/five wire ac power system with rated operation voltage 380v, used for electric power receiving and feeding, reactive power compensation, electric energy calculation, lighting and motor centralized control at power plant, substation, mine enterprises, high buildings. This product complies with the standards gb7251 low-voltage switchgear and control equipment, jb / t9661 low-voltage draw out type switchgear, iec 60439-1 low - voltage switchgear and control equipment. We are pleased to deliver transformer, distribution transformer, power transformer, oil transformer, dry type transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
JH Digital Tension Meters Large, easy to read backlit, graphic display with adjustable backlighting and contrast. Display shows tension, name of calibration selected, running line minimum and maximum tension values, and battery charge level. Indicate length of material in feet or meters.
JH Digital Tension Meters Large, easy to read backlit, graphic display with adjustable backlighting and contrast. Display shows tension, name of calibration selected, running line minimum and maximum tension values, and battery charge level. Indicate length of material in feet or meters. Packaing:59*78*183mm
Folding design feature to use expediently Replaceable pH electrode Clear LCD display featuring both pH, temperature and humidity The KL-0101 offers increased accuracy when measuring solutions at different temperatures as it automatically measures the temperature and compensates the pH reading accordingly.
This compact tester features a large easy-to-read LCD. Unlike other pH testers, the pH electrode can be interchanged with any pH electrode of different size and shape. This allows you to use application specific electrodes and saves the cost of a new meter when it is finally necessary to replace an exhausted electrode. The tester is fast, accurate, lightweight. Testing pH has never been easier!
According to: Technique Regulation of Concrete Defect Detection with Ultrasonic CECS21: 2000 Depth measurement principle When vibration energy transmits through the concrete and passes the crack, the vibrate energy will be diffracted at the point of the crack, whose diffraction angle has geometrical relationship with the crack depth. DJCS-05 crack depth measurement instrument adopts this geometrical between the diffraction angle and depth to realize high precision depth measurement. Feature and Specification Easily operation: Start measure when turn on, simply press to finish testing. Result Intuition: No wave speed test and calculate to display the crack depth directly Data processing: Data can transfer to PC, and then generate test report rapidly. Depth scale: 10-350mm Test precision: 5% Data storage: 10600 depth data Display: 4” Resolution 160*128 Power supply: 9VDC (6 AA battery) Work environment: Temperature -5~40centigrade; Humidity 85% Size: 220*180*80mm Weight: 1000g
Purpose SYQ61 concrete strength tester is used to test compressive strength of concrete by two ways: rebound and ultrasonic-rebound method. Also, it can be used to test sound time and speed in concrete. Specification Technical specification for inspection of concrete compressive strength by rebound method (JGJ/T23-2011) Technical specification for detecting strength of concrete by ultrasonic-rebound combine method (CECS02:2005) Performance 1. Multi-function for testing compressive strength of concrete. It is used to test the compressive strength of concrete by rebound method and ultrasonic-rebound method. 2. Get the compressive strength value of concrete by ultrasonic-rebound method in one instrument. It need two instruments usually, one to test sound speed in concrete, the other to test rebound value. 3. Can save test date. This is convenient for laborer data management. 4. Real USB transmission. Data can be transmitted to computer for future process and analysis. 5. Powerful data process and analysis software in windows. Test data can be export to word or excel for future process and analysis. Technical Data 1. Permissible sound time error: +/- 0.1µs 2. Sensor frequency: 50KHz 3. Rebound kinetic energy: 2.207J 4. Rebound springs Rigidity: 785.0+/-40.0(N/m) 5. Rebound bar impact length: 75.0+/- 0.3 mm 6. Rebound value permission error: =< +/-1 7. Average rebound value on Calibration anvil: 80+/-2 8. Temperature: -4°C ~ +40°C; 9. LCD screen: 160*128(10×8cm) 10. Power: 6 dry cells, work more than 10 times 11. Size: 205mm*173mm*86mm 12. Weight: 850g
KYN28-12 indoor metalclad withdrawable switchgear is designed to be complete distribution equipment with three-phase A.C. singe busbar and single busbar section system having a rated voltage of 3.6~12kV and rated frequency of 50Hz.The switchgear is mainly employed in receiving and distribution of power energy from the network as well as starting of large-sized HV motors. In addition, the switchgear is provided with controlling, protection and monitoring functions. The switchgear conforms to IEC 298, GB 3906, DL/T404-91 and other standards. The switchgear itself owns five prevention functions such as prevention of misoperation of circuit breakers, prevention of pushing or pulling truck with load, prevention of closing earth switch under voltage, prevention of supplying power when earth switch is at the earth position and prevention of entering the electrical separation zone by accident. The switchgear selects not only VS1 vacuum circuit breakers but also ABB made VD4 vacuum circuit breaders, thus recogninzed as power distribution equipment with excellent performance.
The product is suitable for power plant, substation, industrial enterprise, etc. It takes a role of motor distribution, electromotor control in 50/60Hz, max working voltage 660V, max working current 3150A distribution system. The product is high breaking capacity, perfect dynamic stable, reasonable structure, effective electric scheme, strong versatility, multi loops, save acreage, excellent appearance, high protection degree, convenient maintenance, secure and reliable.
XGN2-12 High voltage AC switchgear fixed type metal-enclosed switchgear applied to the 3.6kV~ 12kV three phase AC 50/60Hz system to receive and distribution power energy The device is extensive used for industry. civil cable looped network and terminal power supply, especially for power receipt and distribution for urban residential community, secondary mini-power substation, switching station, industrial and mining enterprises, shopping mall, airport, subway, small and medium power station, hospital, stadium, railway, tunnel etc.. The equipment is the newest metal closed switchgear use air insulation, and it has many advantages such as: simple structure, flexible operation, easy installation, reliable interlocking and so on. Item Unit Rated parameters Model of circuit breaker and isolating switch ZN28-12 VDS-12 Gn30-12G Rated voltage KV 12 Rated current A 630 1250 630 1250 630 1250 Rated short-circuit Breaking current KA 20 31.5 20 31.5 Rated short-circuit Marking current KA 50 80 50 80 Rated dynamic current maximum KA 50 80 50 80 50 80 4S rated thermal stability current KA 20 31.5 20 31.5 20 31.5 Rated insulation level Power-frequency withstand strength in 1 min KV interphase and opposite type: 42 fracture type: 48 Lightning-impulse withstand strength interphase and opposite type: 75 fracture type: 85 Outline size (H*W*D) mm 2300*900*1000 2300*800*1000.
1. Introduction KYN28-12 indoor metalclad withdrawable switchgear is designed to be complete distribution equipment with three-phase A.C. singe busbar and single busbar section system having a rated voltage of 3.6~12kV and rated frequency of 50Hz.The switchgear is mainly employed in receiving and distribution of power energy from the network as well as starting of large-sized HV motors. In addition, the switchgear is provided with controlling, protection and monitoring functions. The switchgear conforms to IEC 298, GB 3906, DL/T404-91 and other standards. The switchgear itself owns five prevention functions such as prevention of misoperation of circuit breakers, prevention of pushing or pulling truck with load, prevention of closing earth switch under voltage, prevention of supplying power when earth switch is at the earth position and prevention of entering the electrical separation zone by accident. The switchgear selects not only VS1 vacuum circuit breakers but also ABB made VD4 vacuum circuit breaders, thus recogninzed as power distribution equipment with excellent performance. 2. Working condition 2.1 altitude: 1000m 2.2 temperature: -10celsius degree ~+40celsius degree 2.3 relative humidity: daily average value 95%, monthly average value 90% 2.4 saturated vapor pressure: daily average value 2.2 10-3MPa, monthly average value 1.8 10-3MPa 2.5 earthquake intensity: less than 8 degree 2.6 protect the product from fire, explosion, earthquake and corrosion atmosphere. 3. Main features: 3.1. the enclosure is completely adopts the aluminum-zinc alloy coated steel sheet, which are machined and bent by machine tool and then bolted; 3.2. all the operations are under the door closing condition 3.3. with high protection category, can prevent intruding of sundries and insects 3.4. simple efficient 5 protection function can prevent operating incorrectly 3.5. the removing compartment of the switchgear may be assembled with VS1(ZN63A) or VD4 vacuum circuit breaker according to customer s demand 3.6. the replacing of VCB is simple and the interchangeability of truck is good. 3.7. the cabinet body can be installed against the wall, so the maintenance can be made in front of the cabinet and the cover area can be reduced too. 3.8. cable compartment has enough room, can connect muti-cable 3.9. high speed earthing switch is used for grounding and loop short circuit 3.10. VCB vault, relay vault and cable vault can add extra heater separately according the demand of customer, in order to avoiding condensation pheromone and corrosion. 3.11. VCB vault and cable compartment can add extra lighting device separately, in order to convenient maintenance. 4. Main technical parameters 4.1 main technical of vacuum switchgear item unit parameter Rated voltage kV 3.6 7.2 12 Rated current A 630 1250 1600 2000 2500 3150 Rated frequency Hz 50 Rated short-time withstand current kA 16 20 25 31.5 40 Rated peak withstand current kA 40 50 63 80 100 Rated power-frequency withstand voltage kV 42/1min Rated lightning impulse withstand voltage kV 75 Rated duration of short circuit S 4 Degree of protection IP4X 4.2main technical parameters of vacuum circuit breaker Item Unit Parameter Rated voltage kV 12 Rated current A 630 1250 1600 2000 2500 3150 Rated short circuit breaking current kA 25 31.5 40 Rated short-time withstand current kA 25 31.5 40 Rated short circuit making current kA 63 80 100 Rated short-time power-frequency withstand voltage kV 42/1min Rated lightning impulse withstand voltage (peak) kV 75 Rated short circuit duration S 4 Closing time (rated voltage) ms 35 t 70 Opening time (rated voltage) ms 20 t 50 Rated breaking times of short circuit times 50 (40kAis 30) Mechanical life times 20000 4.3main technical parameters of operation mechanism Item Unit parameter Rated operation voltage Opening coil V DC220/110 AC220/110 Closing coil Rated operation current Opening coil A (DC/AC)220/110V: 0.9/1.8 Closing coil (DC/AC)220/110V: 1.0/2.0 Power of energy storage motor W 70 Rated voltage of energy storage motor V DC220/110 AC220/110 Energy storage time S 15 5. Structure instruction The basic structure of switchgear panel comprises the panel itself and a removing part (truck). The enclosure and clap-board of the switchgear is bolted with Al-Zn alloy coated steel.Enclosure protection degree of switchgear is IP4X, and the protection degree of every vault is IP2X. 800/1000*1500*2300mm.
Overview: The RT6103B Multi-function single phase energy meter test instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter(Accuracy class:0.1/0.05), Multi-path voltage transformer: Accuracy class:0.01;Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum). 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion: Both voltage and current
Overview: The RT6103F Anti-tamper Single Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05)Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum) 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã 6. Frequency:45Hz~65Hz,Resolution:0.01Hz 7. Output waveform distortion: Both voltage and current
Overview: The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion:Both voltage and current
Overview: The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion: Both voltage and current