Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG35DC-G Use Car, BOAT Type SERVO MOTOR Construction Permanent Magnet Commutation Brushless Protect Feature IP 67 Rated Power(kW)/ Voltage(V dc) 30/640 Peak Power(kW)/ Voltage(V dc) 40/640 Rated/peak Speed(rpm) 1800/2400 Voltage Range(V dc) 300-750 Max Current(A dc) 200 2 in 1 Efficiency (Gen+GCU) >94% Cooling Requirements Inlet Temp.
Speed(RPM) 2200/2500rpm Continuous Current(A) - Efficiency >92% Other attributes Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG15DC-GD Use BOAT, Car Type 2-in-1 non rare earth excitation DC generator Torque - Construction - Protect Feature - Name Rawsuns 15kW 2200RPM 2-in-1 non rare earth excitation DC generator Rated power (kW)/Voltage (V dc) 15/576 Peak power (kW)/Voltage (V dc) 15/576 Generation voltage range (V dc) 144~ 750 Maximum generating current (A dc) 200 Water cooling requirement Inlet Temp.
Speed(RPM) 3600/4500rpm Continuous Current(A) - Efficiency 89% Other attributes Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG12DC-G Use BOAT, Car Type 2-in-1 non rare earth excitation DC generator Torque - Construction - Protect Feature - Name Rawsuns 12kW 3600RPM 2-in-1 non rare earth excitation DC generator Rated power (kW)/Voltage (V dc) 12/324 Peak power (kW)/Voltage (V dc) 20/324 Generation voltage range (V dc) 144~ 750 Maximum generating current (A dc) 200 Water cooling requirement Inlet Temp.
Speed(RPM) 3600/4500rpm Continuous Current(A) - Efficiency 89% Other attributes Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG12DC-G Use BOAT, Car Type 2-in-1 non rare earth excitation DC generator Torque - Construction - Protect Feature - Name Rawsuns 12kW 3600RPM 2-in-1 non rare earth excitation DC generator Rated power (kW)/Voltage (V dc) 12/324 Peak power (kW)/Voltage (V dc) 20/324 Generation voltage range (V dc) 144~ 750 Maximum generating current (A dc) 200 Water cooling requirement Inlet Temp.
Speed(RPM) 3600/4500rpm Continuous Current(A) - Efficiency 89% Other attributes Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG12DC-G Use BOAT, Car Type 2-in-1 non rare earth excitation DC generator Torque - Construction - Protect Feature - Name Rawsuns 12kW 3600RPM 2-in-1 non rare earth excitation DC generator Rated power (kW)/Voltage (V dc) 12/324 Peak power (kW)/Voltage (V dc) 20/324 Generation voltage range (V dc) 144~ 750 Maximum generating current (A dc) 200 Water cooling requirement Inlet Temp.
Speed(RPM) 3600/4500rpm Continuous Current(A) - Efficiency 89% Other attributes Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG12DC-G Use BOAT, Car Type 2-in-1 non rare earth excitation DC generator Torque - Construction - Protect Feature - Name Rawsuns 12kW 3600RPM 2-in-1 non rare earth excitation DC generator Rated power (kW)/Voltage (V dc) 12/324 Peak power (kW)/Voltage (V dc) 20/324 Generation voltage range (V dc) 144~ 750 Maximum generating current (A dc) 200 Water cooling requirement Inlet Temp.
Speed(RPM) 3600/4500rpm Continuous Current(A) - Efficiency 89% Other attributes Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG12DC-G Use BOAT, Car Type 2-in-1 non rare earth excitation DC generator Torque - Construction - Protect Feature - Name Rawsuns 12kW 3600RPM 2-in-1 non rare earth excitation DC generator Rated power (kW)/Voltage (V dc) 12/324 Peak power (kW)/Voltage (V dc) 20/324 Generation voltage range (V dc) 144~ 750 Maximum generating current (A dc) 200 Water cooling requirement Inlet Temp.
Speed(RPM) 3600/4500rpm Continuous Current(A) - Efficiency 89% Other attributes Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG12DC-G Use BOAT, Car Type 2-in-1 non rare earth excitation DC generator Torque - Construction - Protect Feature - Name Rawsuns 12kW 3600RPM 2-in-1 non rare earth excitation DC generator Rated power (kW)/Voltage (V dc) 12/324 Peak power (kW)/Voltage (V dc) 20/324 Generation voltage range (V dc) 144~ 750 Maximum generating current (A dc) 200 Water cooling requirement Inlet Temp.
Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG30DC-D Commutation Brushless Rated Power(kW)/ Voltage(V dc) 30/640 Peak Power(kW)/ Voltage(V dc) 40/640 Rated/peak Speed(rpm) 1800/2400 Voltage Range(V dc) 300-750 Max Current(A dc) 200 2 in 1 Efficiency (Gen+GCU) >94% Cooling Requirements Inlet Temp.
Speed(RPM) 2500rpm Continuous Current(A) 200Adc Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG75DC-GD Use Car, BOAT Protect Feature IP 67 Rated Power(kW)/ Voltage(V dc) 75/618 Peak Power(kW)/ Voltage(V dc) 95/618 Rated/peak Speed(rpm) 2500/3000 Voltage Range(V dc) 500-750 Max Current(A dc) 200 2 in 1 Efficiency (Gen+GCU) >94% Cooling Requirements Inlet Temp.
Warranty 12 months Place of Origin Guangdong, China Brand Name Rawsuns Model Number RG40DC-G Protect Feature IP 67 Product Name Rawsuns 2 in1 Non-Rare-earth DC excitation Generator Rated Power(kW)/ Voltage(V dc) 40/540 Peak Power(kW)/ Voltage(V dc) 50/540 Rated/peak Speed(rpm) 3600/4500 Voltage Range(V dc) 350-750 Max Current(A dc) 200 2 in 1 Efficiency (Gen+GCU) >93% Cooling Requirements Inlet Temp.
Place of Origin Guangdong, China Purpose for replace/repair Condition New Model Number RSG230 Brand Name Rawsuns Product name Generator ev conversion kit RSG230 Application electric vehicle SAE number 3 Rated torque (Nm) 120 Peak torque (Nm) 230 Rated power (kW) 50 Peak power (kW) 85 Rated speed (rpm) 3980 peak efficiency 50% Peak current (A) 320
Warranty 1 year Place of Origin Guangdong, China Brand Name Rawsuns Model Number RSG240 Type Synchronous Motor Frequency 50/60Hz Phase Three-phase Protect Feature IP 67 Efficiency 95% Product Name Rawsuns generator SAE motor ev kit electric boat RSG240 Application Large tonnage vehicles and boat flywheel shell SAE number 3 rated power (kw) 21 Peak power (kW) 35 Rated torque (Nm) 144 Peak torque (Nm) 240 Rated speed (rpm) 1400 Peak speed (rpm) 3500 peak efficiency 95%
Automatic lightning surge generator (Lightning surge immunity tester) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards. Specifications: Product Model SG61000-5SA SG61000-5SB SG61000-5 SG61000-5H-SP SG61000-5T Output Voltage (Open) 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% Output Current (Short) 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% Output Impedance 2�© and 12�© 2�© and 12�© 2�© and 12�© 2�© 12�© and 500�© 2�© and 12�© Output Voltage Range 0~4.8KV�10% 0~4.8KV�10% 0~6KV�10% 0~10KV�10% 0~6KV�10% Output Current Range 0~2.4KA�10% 0~2.4KA�10% 0~3KA�10% 0~5KA�10% 0~3KA�10% Surge Repetition 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times Interval Time 20~9999s 20~9999s 20~9999s 30~9999s 20~9999s Polarity Positive, Negative or Positive/Negative automatic Phase Shift Asynchronous, Synchronization 0�~ 360� or Specific Angle Special Function N/A Built-in surge voltage and current probe (1000:1), connect with LISUN OSP1102 directly Operation Way Button Input Touch screen with super big LCD and built-in Windows CE Dimensions (WxDxH) 44x45x35cm 44x45x35cm 44x45x35cm 56x69x155cm 44x45x55cm Gross Weight About 30kg About 30kg About 30kg About 270kg About 48kg Coupling/Decoupling Network (CDN) Includes a 16A single phase CDN Includes a 20A 3phases CDN Isolution Transformer for EUT (Option) LISUN ITEU-SP4K (220V Single phase) or ITUS-SP2K (110V) Remark: 12KV, 15KV, 20KV and more higer voltage Surge Generator can be designed according to customer request. 6KV Short Circuit Current Output Waveform (780:1) 6KV Open Circuit Voltage Output Waveform (1000:1)
Product description The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts: Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement. The General Conditions of Use Altitude: 1000m Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates Impulse voltage generator (2) Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF); (2)Truncated wave: cut-off time (2-6) 10% s, zero-crossing coefficient 0.3% (3)Standard operating impulse voltage wave 250 20% s / 2500 60% s, The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards. 7, the lowest output voltage is greater than 10% of the nominal voltage 8. Duration of use: Above 70% of rated voltage, it can be continuously operated every 120 seconds after charging and discharging. It can be continuously operated after charging and discharging every 60 seconds under 70% of rated voltage. One computer is used for control and waveform analysis 18-inch LCD monitor, strong anti-interference and long life WINDOWS XP, OFFICE 2003, LabVIEW related driver software, ACE measurement and control software package,built in
Products Introduction Ultra-low frequency dielectric strength testing is another method of power frequency withstand voltage testing, because large-capacity testing is required, and large-scale equipment is not only expensive, but also bulky. The power department did some tests to solve these problems. According to domestic and foreign tests, this product can solve this problem. Not only the size of the instrument is small, but the weight is greatly reduced. Precautions When carrying out 35KV cable test, one-phase test is strongly suggested. Voltage is set to 60KV (General Requirements)-78KV (according to the rules needed) and the frequency is set to 0.1Hz, 0.05Hz,0.02Hz and 0.01Hz. The manual said load capacity is the theoretical value, the scene 35KV cable length can reach 3-15 km. In case the cable is too short(less than 500 meters), the capacitance of the test object is smaller than 0.1 F and the pressure cannot be normally boosted, please connect 0.1 F high-voltage capacitance in parallel way. Keep high-voltage terminals nylon spin by the above numbers to the corresponding nylon seat, high-voltage lines to ensure good contact , no contact is good , it will cause a discharge , burned the high side . When nylon terminals tightened, pay attention to the intensity, excessive tightening may damage the nylon terminals. 80KV 0.1HZ VLF high voltage generator Model Rated Voltages Load capacity Fuse Weight Useful VLF-80 80kV (peak ) 25A
Product description The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts: Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement. The General Conditions of Use Altitude: 1000m Ambient temperature: 5 40 Relative humidity: 90 20 Use of the environment: indoor Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates Impulse voltage generator (2) Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF); (2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3% (3)Standard operating impulse voltage wave 250 20% s / 2500 60% s, The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.
Products Introduction Very Low Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use. Technical Parameter
Product description The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts: Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement. The General Conditions of Use Altitude: 1000m Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates Impulse voltage generator (2) Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF); (2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3% (3)Standard operating impulse voltage wave 250 20% s 2500 60% s,
Products Introduction VLF high voltage generator 60KV.The capacity of it is 1/500 of tradition way. Greatly simplify testing procedures, That is why commonly used in the developed , s ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test. Power capacitance of single-core XLPE insulated cable (F/km) 0.1Hz -60KV Ultra-Low Frequency High Voltage Generator Model Rated Voltages Load capacity Fuse Weight Useful VLF-60 60kV (peak ) 0.1Hz,0.5F 25A Control 6 HV TANK-30 HV TANK-II33 25KV and below the cable