For fixed installations in devices and in or on lights, as well as for the house installation, especially for uses by their one low creation is demanded of smoke and corrosive gases in the fire case, however not outside.
H05V-R/H07V-R is suitable for power and lighting circuits and building wiring. The cable is intended for use in semi-flush exposed conduits and embedded conduits as well as in closed installation ducts, and is ideal for the internal wiring of appliances.
Conductor Class 5 flexible copper conductor Insulation PVC (Polyvinyl Chloride) Insulation Colour Red Black Blue Orange Yellow White Green/Yellow Grey Brown Violet Pink
[1] CONDUCTOR Electrolytic copper, class 5 according to EN 60228. [2] INSULATION PVC. [3] SHEATH Flexible PVC, black or white colors.
Conductor Plain annealed stranded copper conductor class 2 as per BS EN 60228. Insulation Extruded layer of Polyvinyl chloride (PVC) insulation with temperature rating 70 C at normal operation as per BS EN 50363-3 type TI1
Conductor Class 5 flexible copper conductor Insulation PVC (Polyvinyl Chloride) Sheath PVC (Polyvinyl Chloride) Sheath Colour Blue Grey Green/Yellow Special colours to order
The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy Cable is composed of the conductor with moisture block in the strands, covered by a semi-conducting cross-linked polyethylene strand shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield Conductors are available with either 100% or 133% insulation levels Concentric neutral of bare copper wires and an insulating polyethylene jacket is applied over the insulation shield Cable identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket
1.Solid or stranded copper/aluminum conductor 2.Insulation with XLPE, PE, or PVC 3.For cables of two-phase or three-phase conductors, round or flat shape available 4.PVC inner COVERING 5.Concentric layer of helically layed copper/aluminum wires 6.Wrapping tape 7.Black XLPE, PE, or PVC jacket
0.6/1 kV Multi-core cables, XLPE insulated, wire armoured with aluminum conductor Construction : AL/XLPE/SWA/PVC (Stranded Aluminum Conductors/XLPE Insulated/Steel Wire armoured/PVC Sheathed)
0.6/1 kV Multi-core cables, PVC insulated, tape armoured with aluminum conductor AL/PVC/STA/PVC (Stranded Aluminum Conductors/PVC Insulated/Steel tape Armoured/ PVC Sheathed)
0.6/1 kV Multi-core cables, PVC insulated, unarmoured with copper conductor
0.6/1 kV Multi-core cables, PVC insulated, tape armoured with copper conductor CU/PVC/STA/PVC (Stranded Copper Conductors/PVC Insulated/Steel tape Armoured/ PVC Sheathed)
0.6/1 kV Single-core cables, PVC insulated, wire armoured with aluminum conductor AL/PVC/AWA/PVC (Stranded Aluminum Conductors/PVC Insulated/ Aluminium Wire Armoured/ PVC Sheathed)
0.6/1 kV Single-core cables, PVC insulated, wire armoured with copper conductor CU/PVC/AWA/PVC (Stranded Copper Conductors/PVC Insulated/ Aluminium Wire Armoured/ PVC Sheathed)
0.6/1 kV Multi-core cables, PVC insulated, unarmoured with aluminum conductor
0.6/1 kV Multi-core cables, PVC insulated, unarmoured with copper conductor These cables are intended for fixed installations, indoors and outdoors, in low voltage electricity systems. They are normally used for the distribution of electrical energy in urban networks, power or switching stations, industrial plants, as well as in switchgears, in applications where there is no risk of mechanical damage
0.6/1 kV Single-core cables, PVC insulated, unarmoured with aluminum conductor These cables are intended for fixed installations, indoors and outdoors, in low voltage electricity systems. They are normally used forthe distribution of electrical energy in urban networks, power or switching stations, industrial plants, as well as in switchgears, in applications where there is a risk of mechanical damage.
0.6/1 kV Single-core cables, PVC insulated, unarmoured with copper conductor These cables are intended for fixed installations, indoors and outdoors, in low voltage electricity systems. They are normally used forthe distribution of electrical energy in urban networks, power or switching stations, industrial plants, as well as in switchgears, in applications where there is a risk of mechanical damage.
Conductor: Class 2 Circular compacted stranded Aluminium Conductor Screen: Extruded semi-conductive layer Insulation: XLPE (Cross-linked polyethylene) Insulation Screen: Extruded semi-conductive layer Separator: Semi-conductive tape Outer Sheath: HDPE (High Density polyethylene)
Phase Conductor: Concentric strand or compressed 1350-H19 conductor Neutral Conductors: aluminum alloy 1350-H19,6201-T81, or ACSR conductors Insulation: high density polyethylene (HDPE) or cross-linked polyethylene (XLPE).