I. Introduction SS-300-HF Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for online monitoring of organic waste gas emissions and organic waste gas recovery for chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductors, synthetic leather and so on. III. Specifications Monitoring place Gas component Measurement range aluminum oxide outlet HF 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: ,¸8,?6 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load550Ω 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190â??, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. 9.With lens blow up function, to prevent it dewing.
I. Introduction SS-300-HCL Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for stack outlet in the waste incineration power plant. III. Specifications Monitoring place Gas component Measurement range Waste incineration stack outlet HCL 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: 86 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load4 - 20mA 550© 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. With lens blow up function, to prevent it dewing.
I. Introduction SS-300-NH3 Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used to monitor NH3 after SNR or SCNR process in the waste incineration plant, power plant and so on. III. Specifications Monitoring place Gas component Measurement range SNR or SCNR stack outlet NH3 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: ø8Ã?6 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load4 - 20mA 550© 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. 9.With lens blow up function, to prevent it dewing.
I. Introduction The SS-700 process VOCs monitoring system is based on the standards of HJ/T80, HJ/T75, HJ/T76 and other related standards, sampling by extraction method, configuration based on advanced gas chromatography, mass spectrometry separation technologies and hydrogen flame Ionization Detectors (FID), photoionization detectors (PID) to measure the composition of volatile organic gases such as total hydrocarbons (THC), non-methane total hydrocarbons (NMHC), aromatic hydrocarbons, esters, etc. According to the composition and detection requirements in the analysis project, it can be configured to meet the requirements of the analysis project and the frequency of analysis. At the same time, the optimization of instrument configuration can be performed to maximize the use of the instrument and ensure the continuity of sample analysis. reliability. The analysis system fully considers sample gas conditions, dew point and other factors, and specifically designs the pretreatment system to prevent the crystallization of components in sample gas from condensing and changing the concentration of components. The instrument uses special column combination, center cutting and back blowing technology and hydrogen flame ionization detector (FID) technology for detection. The FID Hydrogen Flame Ionization Detector is a typical mass detector that measures the mass change rate of a component in a GC gas. The response value is proportional to the mass of a component entering the detector per unit of time. II. Features 1.The system piping is imported clean stainless steel pipe to reduce adsorption; 2.The system adopts full calibration to eliminate the influence of a small amount of adsorption on the measurement. 3.The analytical method is consistent with the calibration method, and it is detected by GC-FID method. 4.The whole process of high-temperature 180 °C with hot sample transmission, high temperature FID detection, to avoid high-boiling VOCs adsorption and condensation, more accurate measurement; 5.Continuously run maintenance-free design, start-up automatic cycle operation, real online analysis; 6.The whole flow path insulation design is 180°C, no water vapor condensation, to avoid corrosion degradation of parts, suitable for high temperature / high humidity / corrosive conditions; 7.Non-methane total hydrocarbons and simultaneous monitoring of benzene, toluene, xylene and other components III. Application fields It is used for on-line monitoring of organized organic waste gas emissions from chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductor, synthetic leather, organic waste gas recovery.
I. Introduction SS-2000-HG mercury emission monitoring system for flue gas is a combination of the world's advanced online analytical technology and China's environmental protection monitoring technology. It is based on the company's many years of accumulated experience in the field of gas analysis and adopts multi optical path UV atomic absorption method. The system consists of a sampling unit with heat trace, a valence converter, and an analysis and processing unit. It can realize continuous on-line automatic and accurate measurement of mercury from fixed sources of flue gas. The system uses Cold Vapor Atomic Absorption Spectrometry (CVAAS), which is the most mature and stable analytical method among many mercury analysis methods. This method can only analyze the elemental mercury (Hg0) in the vapor state. CVAAS is based on the principle of selective absorption of ultraviolet light with a wavelength of 253.7 nm using mercury vapor. The low-pressure mercury lamp emits ultraviolet light through a gas chamber filled with sample gas and directly monitors the transmitted light intensity with an optoelectronic receiver to calculate the absorbance. Within a certain concentration range, the mercury concentration is proportional to the absorbance, which is in accordance with Beer-Lambert law. At the same time, oxygen, temperature, pressure, flow rate, humidity and other parameters can be monitored. Charts are generated through the data acquisition and processing system, and data remote transmission interfaces are reserved. The monitoring data can be transmitted to all levels of environmental protection according to the HJ/T212 national standard communication protocol. department. II. Specifications 1. Detection method: Cold Vapor Atomic Absorption (CVAAS) 2. Measurement range: 0-100g/m3, 0-500g/m3 3, detection limit: 0.05g/m3 4, response time T90:
1. Introduction SPF223 sampling probe used in the systems for gas sampling, filtration and heating function, can effectively prevent the condensation of gas samples collected, unique structural design allows for a sampling system is more reliable, more small gas loss rate to ensure system stability and true 2. Features The device and the part of the sample contact are all made of 316L stainless steel material processing, high temperature resistance, strong corrosion resistance. With rain cover can do outdoor work environment. Adopting the isothermal heating body, in the design of compact structure, stable heating temperature. Filter element is made of sintering titanium alloy which has big filter area, high accuracy, small air lock, and can be replaced from the device pulled out completely, simple operation, without tools, greatly shorten the maintenance time, and reduce the labor intensity. Optionally providing a reusable purging / calibration port. Operation is simple, with low temperature alarm. The filter replacement without tools. The switch is convenient, with locked cover. High efficiency filter cleaning system. 3. Specifications Maximum sampling temperature: 300 Maximum working pressure: 6BAR Sampling chamber heating temperature: 140 (factory set, adjustable temperature) Power supply: 220VAC 50/60Hz max 500W Environment temperature: -20~80 Maximum dust load: 100g/m3 Filter accuracy: 5μm (other precision optional, 1-10 m) Filter size: 150*35mm Purging gas interface: OD8/6mm connector Sample gas outlet: OD8/6mm connector The sampling pipe containing: 25 * 1200mmlength is optional Flange size: DN65PN6 The installation of accessories: installation flange & fixing bolts & flange sealed pad
1. Introduction Sampling heated tube is one important part of the environment protection monitoring system, widely used for SCNR, SNR, waste incineration and other emission sampling. 2.Specifications Gas pipe material: PVDF, PTFE, 316L, PFA Black knit anti-scratch layer Air tube size: OD8/6mm,OD6/4mm (optional) Power consumption: 10-100W/M (depending on heating tempeature) Power supply: 220VAC 50HZ Sample gas heated temperature50~220 No breakpoint and cold point all the way Using temperature controller to control heating temperature precisely Excellent heat preservation effect Heated tube external diamete: OD38±2mmOD42±2mm Minimum bending: 0.5m Lowest working temperature: -20 Minimum installation distance: vertical 2m, horizonal 4m.
1. Introduction ECM1/2 series gas condenser is used in the sample gas pretreatment system to remove moisture from the sample. Precise measurement of gas composition means sample gas under dew point can be stable even under bad environment. ECM condenser is to improve measurement precision and life span. 2. Features Perfect design, only one component: compressor Two-loop system Two-loop heating exchanger Constant temperature adjusting system with patent With temperature display Temperature alarm Dew point stability: 0.2 Environment protection refrigeration without Freon 3. Specifications 1.Ambient Temp045 6.Dew point Temp4Factory set 2.Temp Control Accuracy±0.27.Power supply220VAC 50/60Hz 3.Gas Inlet Temp80 8.Voltage300V, fuse10A 4.Gas flow rate300L/h 9.IP gradeIP20 5Warming-up Time15 min 10.Installationwall mounted or 19?�rack
I. Introduction SS-UV-300 flue gas analyzer (low emission monitoring) based on years of experience in research and development of flue gas analyzer, combined with the field practice of nearly ten thousand successful application cases. A number of techniques of the flue gas analyzer (standard form) are upgraded (many times return room to increase gas absorption optical path, and higher accuracy of spectrometer, convection heat transfer core module temperature control, etc.). The analyzer is based on DOAS and chemometric algorithms (PLS), able to measure concentration of gases including SO2, NO2, NO, O2, NH3, Cl2, O3, H2S, CH3I, etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions. II. Application fields It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son. III. Specifications Model Standard Low Emission Ultra-low Emission Range 0-300-3000ppm 0-100-300ppm 0-20-100ppm Linearity ±1.5%F.S. Repeatability ±0.5%F.S. Zero Drift ±2%F.S/7d Span Drift ±2%F.S/7d Response time(T90) 10S 30S 30S Working Temp -10-+40 Preheating time No preheating Approx.10 min Sample Gas Interface 6 Sample Gas Flow 0.5-2L/minFluctuation
I. Introduction The analyzer is based on NDIR (Non-dispersive Infrared) technology able to measure concentration of gases including CO,CH4,CO2,SO2,NO etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions. II. Application fields It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son.
We use Heat sublimation,Website:http://www.starflagmakers.com, with vivid colors and distinct layers, can indicate subtle adjacent color differences in detail;Its special colored tape contains a unique protective film, which can achieve successive layers of color. Compared with the semi-color gradation of inkjet, heat sublimation technology has truly achieved the photo quality. As for photo preservation, heat sublimation has more advantages than other printing technologies in waterproofing, UV protection and fingerprint protection due to its protective layer. -
It is a new printing process,Website:http://www.starflagmakers.com, and the printing methods are divided into two parts: transfer film printing and transfer processing; (1)Transfer film printing: using dot-printing (whose resolution ratio is up to 300 dpi), the pattern is printed on the film surface in advance. The patterns have rich designs and colors. With small chromatism and good reproducibility, it can meet the requirements of designers and is suitable for mass production. (2)transfer processing: through the primary processing of the heat transfer machine (pressurizing and heating), the fine patterns on the printing film can be transferred to the product surface. After molding, the ink layer is integrated with the surface of product, vivid and eye-catching. -
Standard flag is also named as corporate flag;Our imported digital printing equipment will solve all the problems of high cost,Website:http://www.starflagmakers.com, high finished product price and cumbersome production process. With advanced imported equipment and mechanized production, we can directly apply landscapes, figures, designs, polyester fabrics, sateen cloth, satin, oxford cloth and canvas, etc. This is characterized by high precision, dot free, environmental protection, waterproof, ultraviolet resistance, bright and lasting color. Meanwhile, the pictures can be sprayed on cloth without transfer or high-temperature furnace, which saves costs and earns time for our customers.transfer processing: through the primary processing of the heat transfer machine (pressurizing and heating), the fine patterns on the printing film can be transferred to the product surface. After molding, the ink layer is integrated with the surface of product, vivid and eye-catching." -
The corporate flagpoles generally use three flagpoles, but Sino-foreign joint ventures or foreign-funded factories may use 5 or more. The height generally is 8-15.8m, which will be higher for multi-floor buildings or office. From 8-10 meters (two floors to three floors higher), the flagpole usually hangs corporate flag size 4, and the 11-13 meters high flagpole usually hangs corporate flag size 3. Corporate flag is a symbol of the company, so the flag color standards for the enterprise. The banner usually prints a company name or logo, which is usually hung together with national flag at doorway, but is lower than national flag. Corporate flag implies the temperament of the enterprise, highlights company's cultural philosophy, reflects enterprise's spirituality and displays corporate individual character, so it is of great significance to a company. url:http://www.starflagmakers.com -
Pdlc Self Adhesive Smart Film,
Pdlc Film Self Adhesive,Self Adhesive Smart Film url:http://www.iwittesmartfilm.com
Pdlc Switchable Self Adhesive Film,
Self Adhesive Pdlc Film,Website
Customized Engineering plastic parts CNC milled Engineering plastic parts, CNC turned Engineering plastic parts, EDM / Wire EDM Engineering plastic parts, Surface Grinding Engineering plastic parts, Welding Engineering plastic parts DESCRIPTION Customized Engineering plastic parts Material: PVC,PE,POM,POM+25%GF,PMMA,PS,ABS,PA6.PA66,PTFE,PEEK Surface Roughness: Max Ra 0.8-1.6 Plating: Industry: Automation and control engineering Automotive and vehicle construction Lighting industry Office machinery and supplies Electrical industry Telecommunication industry Packaging industry Machine tool manufacturing Medical technology Measurement and control technique, laboratory equipment Paper and printing machinery industry Special purpose machinery manufacturing Quantity: 1-5 pcs,5-50pcs.50-500pcs,500-10000pcs.
Customized Assembly parts Customized Assembly parts Customized offered assembly drawing and machining drawings,GPM can delivery as a whole equipment or machines. Especially good at assembly jig and fixtures. DESCRIPTION Customized Assembly parts Customers offered assembly drawing and machining drawings,GPM can delivery as a whole equipment or machines. Especially good at assembly jig and fixtures. Industry: Automation and control engineering Automotive and vehicle construction Lighting industry Office machinery and supplies Electrical industry Telecommunication industry Packaging industry Machine tool manufacturing Medical technology Measurement and control technique, laboratory equipment Paper and printing machinery industry Special purpose machinery manufacturing Quantity: 1-5 pcs,5-50pcs.50-500pcs,500-10000pcs