Superior Hydraulic Design, Without Installation Requirements Of Straight Pipe Wide Turndown Ratio, R is Up To 1000Suitable For Big Volume Flow And Tiny flow Measurement. Suitable For Mass Flow And Tiny Flow Measurement The Design Of Integrated Flow, Pressure, Wireless Reading Meets Monitoring Pipeline Requirement IP68 Protection Class, Whole Meter Sealed Completely Ensures Long Term Underwater Working Double D Size Batteries Can Continuously Work For 15 Years Bi-directional Measuring Forward And Reverse Flow Data Logger Function Can Save 10 Years Data Including Day, Month And Year LCD Display Volume, Flow Rate, Flow Direction, Alarm, Leak Detection At The Same Time Standard RS485 (Modbus-RTU), A Variety Of Options, NB-IOT, OCT, GPRS etc. Electric Components According To ROHS, OSP Processed Circuit Board Stainless Steel Body (SS304) is Integrated Stretching Patent Right Product International Standard Flange Connection, Simple Installation According To Sanitary Standard For Drinking Water
Superior Hydraulic Design, Without Installation Requirements Of Straight Pipe Wide Turndown Ratio, R is Up To 1000Suitable For Big Volume Flow And Tiny flow Measurement. Suitable For Mass Flow And Tiny Flow Measurement The Design Of Integrated Flow, Pressure, Wireless Reading Meets Monitoring Pipeline Requirement IP68 Protection Class, Whole Meter Sealed Completely Ensures Long Term Underwater Working Double D Size Batteries Can Continuously Work For 15 Years Bi-directional Measuring Forward And Reverse Flow Data Logger Function Can Save 10 Yearsâ??Data Including Day, Month And Year LCD Display Volume, Flow Rate, Flow Direction, Alarm, Leak Detection At The Same Time Standard RS485 (Modbus-RTU), A Variety Of Options, NB-IOT, OCT, GPRS etc. Electric Components According To ROHS, OSP Processed Circuit Board Stainless Steel Body (SS304) is Integrated Stretching Patent Right Product International Standard Flange Connection, Simple Installation According To Sanitary Standard For Drinking Water
Prices Mentioned above is for base model only
Prices Mentioned above is for base model only
Prices Mentioned above is for base model
Code : MK-02 Product : Milkfish / Bangus Latin Name : Chanos Chanos Size : 150gr-500gr, 500gr-800gr, 800gr-1000gr & 1000 gr up Description : fresh or frozen milkfish for consumption.
Accuracy & repeatability · Accuracy: +/-0.5% of reading from 0.03ft/s to 40ft/s (0.01 to 12m/s) · Repeatability: +/-0.15% of reading Description · Transit-time ultrasonic · Clamp on transducer and insertion transducer versions · High accuracy at low and high flows · Bi-directional flow · Clear, user-friendly menu selections Fluids measured · Water and liquids, tolerant of liquids with small amounts of air bubbles or suspended solids Flow range · Bi-directional flow range of 0.03ft/s to 40ft/s (0.01 to 12 m/s) Pipe sizes from 1 to 200 inches (25 to 5000mm) Digital communications · RS-485, Modbus RTU SD card · Standard SD card · Max record: 512 days · Record time interval Outputs · OTC pulse output :0~9999 Hz · Analog output : 4~20mA · Max load 750Ω Temperature · Transmitter: -40-140F (-40-60C) · Transducer: -40-176F (-40-80C)
Accuracy & repeatability Accuracy: +/- 1.0% of reading from 0.03ft/s to 40ft/s (0.01 to 12m/s) Repeatability: +/- 0.3% of reading Description ·Transit-time ultrasonic ·Handheld, easy to carry ·Clamp-on outside of pipe for easy set up ·No pipe cutting or process shutdown ·High accuracy at low and high flows ·Bi-directional flow Fluids measured Water and liquids; Tolerant of liquids with small amounts of air bubbles or suspended solids Flow range Bi-directional flow range of 0.03 ft/s to 40 ft/s (0.01 to 12 m/s) Pipe sizes from 1 to 48 inches (25 to 1200mm) Pipe material Carbon sheet ; stainless sheet ; PVC Digital communications RS-485, Modbus RTU Out puts OTC pulse output :0~5000 Hz Analog output : 4~20m A , max load 750Ω Temperature Transmitter: 14F~122F(-10C~50C) Transducer: 32F~176F(0C~80C)
Handheld ultrasonic flow meter Installation method: Handheld SD card high memory data logging, maximum memorize 512 days data. Flow range: +/-0.03 ft/s ~ +/-40 ft/s (+/-0.01 m/s~ +/-12 m/s) Accuracy: +/-0.5% of measured value Repeatability: 0.15% Output: 4-20mA Internal lithium power supply: 10hours Pipe size range: 0.6â?³~240â?³(15mm~6000mm) Transducer: IP54, CP magnet portable transducer, 5m cable
Manual Water Meter : Watflux is the best in industry for manufacturing and supply of Residential Water Meters. We can provide all kinds and all sizes of water meters. Watflux has variants such as Manual Water Meter, Digital Water Meter and Ultrasonic Water Meter.
pHG-1901 industrial online PH meter is a precision meter for measurement of the PH value of solution. With complete functions, stable performance, simple operation and other advantages, they are optimal instruments for industrial measurement and control of PH value. Various PH electrodes can be used in pHG-1901 industrial online PH meter. Features LCD display, high-performance CPU chip, high-precision AD conversion technology and SMT chip technology, Multi-parameter, temperature compensation, high precision and repeatability US TI chips; 96 x 96 world-class shell; world-famous brands for 90% parts The current output and alarm relay adopt optoelectronic isolating technology, strong interference immunity and the capacity of long-distance transmission. Isolated alarming signal output, discretionary setting of upper and lower thresholds for alarming, and lagged cancellation of alarming. High-performance operational amplifier, low temperature drift; high stability and accuracy. Technical Indexes 1. Measuring range: 0~14.00pH, Resolution:0.01pH 2. Precision:0.05pH,±0.3 3. Stability:â?¤0.05pH/24h 4.Automatic temperature compensation: 0~100(pH) 5.Manual temperature compensation:0~80(pH) 6. Output signal: 4-20mA isolated protection output, dual current output 7. Communication interface:RS485(optional) 8. Control interface: ON/OFF relay output contact 9.Relay load: Maximum 240V 5A; Maximum l l5V 10A 10. Relay delay: Adjustable 11.Current output load:Max.750Ω 12. Insulation resistance:â?¥20M 13. Power supply: AC220V ±22V, 50Hz ±1Hz 14. Overall dimension: 96(length)x96(width)x110(depth)mm;dimension of the hole: 92x92mm 15. Weight: 0.6kg 16. Working condition: ambient temperature:0~60, air relative humidity:â?¤90% Except for the earth magnetic field, there is no interference of other strong magnetic field around. Standard configuration One secondary meter, the mounting sheath of immerged (selection), one PH electrode, three packs of standard Ordering guide: 1. To inform whether the electrode provided is a dual or ternary complex. 2. To inform the length of the electrode cable (default as 5m). 3. To inform the installation type of the electrode: flow-through, immerged, flanged or pipe-based
In our company, we have the stock of Diesel flow meter of all calibers. From this, it is not hard to find that our company has sufficient funds and our products sale good. Nowadays, there hardly exist companies who own the ability to keep stock. But we dare and have the strength to do that.
Our company cherish the slogan quality in Germany and the price in China to make world-class Diesel flow meter and to be the benchmarking enterprise in the automatic instrument industry.
Horizontal Woltmann Water Meter with large turn-down is used for accurate measurement of water distribution. Features: Available in sizes NB 50 mm to 500 mm. Guarantees a high measuring accuracy. Long-term stability of the measuring results. These are manufactured strictly as per latest International standards confirming to ISO 4064 Class B.
Horizontal Woltmann Water Meter with large turn-down is used for accurate measurement of water distribution. Features: Available in sizes NB 50 mm to 500 mm, Guarantees a high measuring accuracy and Long-term stability of the measuring results. These are manufactured strictly as per latest International standards confirming to ISO 4064 Class B.
Material: Tempered glass, borosilicate glass Shape: round, square, T-shape, special shape Size: Diameter 20mm-300mm, Thickness 1.5-20mm Processing: grinding, chamfer, drilling, laminated,polishing, silk-screen, etc.
We can also provide the following products: Burkert flow transmitter Gf signet flow transmitter Foxboro flow transmitter Yokogawa flow transmitter Honeywell flow transmitter Coriolis flow transmitter Rosemount flow transmitter Siemens flow transmitter. -
Fter processing by the control instrument and convert into the quantities, so as to realize the continuous measurement of material level, improve the reliability and makes it very easy to installation and debugging Iii.Product features: *simple calibration: can use any of the two points of any warehouse height automatically complete the calibration *strong adaptability:can work reliable under high temperature, high pressure, strong corrosion, strong adhesion and strong dust environment. *no maintenance: because simple structure of the sensor and no moving parts, so once put into operation , it no need to maintenance. *widely used: liquid, solid, interface mixture, material etc. *lcd display: adopt lcd, display rich and comprehensive content. *no drift: no drift because the medium of the temperature or density changed. *reliable life: unique technology ensures the long service life of the instrument to15 years Paper ctn.
I.Measurement principle: Transmit very low energy and very short microwave pulse then transmitting and receiving by the antenna system.Radar wave are running at the speed of light.Running time can be transformed into material level signal by electronic parts.A special type of time extension method can guarantee the stability and accurate measurement in a very short time. Even if the condition is complex , has false echo, can accurately analyze the level of the echo with the latest micro-processing technology and debugging software. Paper ctn.
Power supply: two lines(dc24v) four lines(dc24v/ac220v) The scene display: four figure lcd(programmable) Shell: optional Process connection: screw thread/flange(optional) The antenna:bellmouth (stainless steel 316l) Wooden case