S509 IR CO2 Gas Sensor Characteristics: * -40'C~+70'C wide working temperature range high precision measurement * Sensor automatic revision, zero drift an automatic adjustment * Immune to poisonous and harmful material, have fight poisoning efficacy * Work without oxygen to participate in * Using the infrared principle scattered, and long service life * Sensor work, can output the digital quantity and analog * Has the standard output interface, peripheral use circuit is simple Infrared gas sensor is based on bill-LangBo law and ir theory developed, we can accurately detect methane, carbon dioxide, hydrocarbons, etc. Sensor interior has intelligent processing chip, the gas absorption of light signal conversion into gas concentration information, and digital signal and linear output voltage signal and through the software algorithm in complex linearization and precise processing temperature and humidity compensation of gas density per second, and a time interval according to certain packet format automatically send output. When offered 3.0VDC ~ 6.0VDC range voltage, S509 infrared sensor can be in -40'C ~ +70'C Wide temperature range normal work. The sensor to provide analog and digital output interface. The user can through the interface auto receiving gas concentration data and execution, use the function such as calibration is very simple. S509 IR CO2 Gas Sensor Specification * Working voltage: 3.0 - 6.0V * Resolution: 1°FS. * Response timeT90: 30S * Measurement accuracy: ±3%FS * Zero repeatability: ±1%FS * Long-term zero drift: ±1%FS/year * Working temperature: -40'C~+70'C * Working humidity: 0~95%RH No condensation
AR8200 Carbon Dioxide Detector CO2 Detector Introduction This Carbon Dioxide detector can detect the Carbon Dioxide content between the 0~5000ppm and shows the Carbon Dioxide volume with an LCD. The product features: * As it uses the imported Carbon Dioxide sensor, it is very precise and its performance is stable. * It uses the intellectualized design and has gotten multiple functions. * With highlight backlight display and acoustic-optic alarming, it is easily configured. * The embedded temperature compensation can make the meter measuring the correct value in the environment temperature of -10~40'C. * As its case is ergonomically designed, it looks handsome, feels good and is easy to carry. AR8200 Carbon Dioxide Detector CO2 Detector Applications: * Carbon Dioxide manufacturing workshop * Petroleum refining and petrochemical plants * Carbon Dioxide content detecting in trains and automobiles * Carbon Dioxide content detecting in minerals * Carbon Dioxide content detecting during mountain climbing and in sealed place * Other industries and plants using Carbon Dioxide. AR8200 Carbon Dioxide Detector CO2 Detector Technical Features â?¢ Gas Type: Carbon Dioxide (CO2) * Measuring range: 0 to 5000ppm * Resolution: 1ppm * Measuring Principle: Optics * Display: Large LCD Display * Operation Tempearture: -10'C ~ 60'C * Operation Humidity: 0 to 99.9% RH * Power supply: 3 x 1.5V AA battery * Size: 182*66*32(mm)
Carbon Monoxide Detector And Transmitter Model#: F2000TSM-CO-C101 * Real time detect and transmit ambiance carbon monoxide level * Up to more than five years lifetime * 1x analog output for linear measurement * Modbus RS485 interface * The highest performance with the lowest price F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Description F2000TSM-CO-C101 is specifically designed to detect and transmit carbon monoxide level in the enclosed or semi-enclosed car parks and to regulate the environment according to the measurement of carbon monoxide. It is designed for easy installation and minimum maintenance during operation. F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Features * Wall mounting, real time detect CO level with measuring range of 0~100ppm/ 0~200pm/ 0~500ppm. * Electrochemical sensor which offer several advantages over traditional electrochemicalsensors. * With a long life, good long term stability, and high accuracy, the CO sensor is environmentally friendly without risk of electrolyte leakage. * With simple calibration * The special design of easy sensor's replacement makes customers replace sensor easily by themselves * Full time CO level detection, even the slightest leak can be detected * One analog output of the measurement of carbon monoxide concentration with 0~10V/4~20mA selectable * Special built-in Self-Zero Correction algorithm. * Modbus RS-485 communication with 15KV antistatic protection, also can be calibrated carbon monoxide measurement via the interface F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Application * Residential and commercial CO detectors and transmitters * Ventilation control for indoor parking garages * Recreational vehicle CO detectors * Kitchen rooms and restaurants * Freezing machine rooms and other places where air quality is easy to worsen F2000TSM-CO-C101 Carbon Monoxide Detector and Transmitter Specifications * Gas detected: Carbon monoxide * CO Measuring Range: 0~100ppm(default); 0~200ppm/0~500ppm selectable * Response Time: Within 60 seconds * Accuracy:
Ar820 formaldehyde gas detector introduction Ar820 household formaldehyde gas detector, which adopts imported advanced sensors, are of excellent performance, high accuracy and stability, and are able to implement continuous real-time detection. This type of detectors can be applied in household, offices and any other dwellings. Ar820 formaldehyde gas detector product specifications * measurement range: 0~5.0 ppm * resolution: 0.01 ppm * accuracy: ±5% * temp. Measuring range: 0'c~40'c/32'f~104'f * temp. Resolution: 0.1'c/0.1'f * temp. Accuracy: ±2'c * humidity measuring range: 10~95%rh * humidity resolution: 0.1%rh * humidity accuracy: ±5%rh
As8900 4 in 1 muilt gas monitor introduction The as8900 multi-gas monitor is a portable and handheld instrument that is capable to use continuously and simultaneously monitoring 4 gases: oxygen, combustile gas, carbon monoxide and hydrogen sulfide. Every gas readings all shows in one lcd display. The unit also provide user to configure high and low alarm as well as twa and stel alarms. The unit will be audio and visual alarm once the alarm condition is exceeded. As8900 4 in 1 muilt gas monitor specifications * range: Oxygen (o2): 0~30% Combustile (lel): 0~100% lel Carbon monoxide (co): 0~999 ppm Hyrogen sulfide (h2s): 0~500 ppm * operating temperature: -10~ 50'c(except lel is 0 ~40'c) * operating humidity: 15~95 % rh, typical * size: 120.20 x 64.50 x 38.30mm * weight: 200g
Product Features Integrated DFB grating provides single frequency operation Frequency tuning can be accomplished by adjusting either laser drive current or temperature. Tuning range up to 6 nm without mode hopping Temperature tuning control: 0.1 nm / 'C Drive current tuning control: 0.04 nm / mA Typical output power range: 2-8 mW Packaging Options TO-39 or TO-66 package Glass or Sapphire window with 7' slope Hermetically sealed Integrated thermoelectric cooler (TEC) Mounted lens for collimation Butierfly package with fibre coupled output Applications Molecular spectroscopy Industrial gas sensing (TDLAS) Environmental monitoring
Air cleaner safety element 60123505 Suitable for Sany Excavator Truck SY35 As a leading supplier of parts suitable for construction and mining equipment we provide SDLG, XCMG, SANY, LIUGONG, LGMG and TONLY OEM parts
Air Washer, Axial Flow Fan, Air Filters, Air Handling, Air Diffuser,
1. Used for agriculture spraying. 2. Used as cooling mist system 3.Used for car washing. Applicable scope: We suited for wheat,corn,rice,fruit tree,greenhouses,grapes,,tea,horticulture and other agriculture crops spraying,also suited for the large spaces pest control and sanitation prevention.An excellent sprayer designed for continuous work for remote areas in the wild,high mountains,tea plantations.
Types:HEPA Filter Efficiency:99.95%-99.99% Be Used For:Purifier, Air Conditioning, Fresh Air Ventilator
The UV-Clean Air is the best solution for purifying and disinfecting air flow within the air duct at Hospitals, Corporates, Plazas and every commercial space.
AC Filter
Air filter compressed air filter 1). Separator filter (HF9) For bulk liquid removal plus a 3 micron coalescer (5ppm w/w maximum remaining oil content) Two-stage filtration * First stage: two stainless steel orifice tubes provide 10 micron mechanical separation * Second stage: in-depth fiber media captures solid and liquid particles to 3 micron 2). Air line filter (HF7) For removal of liquid water and oil; removes solid particles to 1 micron (1.0 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two-stage filtration * Firt stage: captures larger particles with alternate layers of fiber media and media screen * Second stage: coalesces aerosols and captures solid particles with multiple layers of epoxy bonded, blended fiber media 3). High efficiency oil removal filter (HF5) For coalescing fine water and oil aerosols; removes solid particles to 0.01 micron (0.01 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * First stage: multiple layers of bonded, blended fiber media for fine coalescence * Second stage: multiple layers of bonded, blended fiber media for fine coalescence Outer coated, closed cell foam sleeve 4). Ultra high efficiency oil removal filter (HF3) For coalescing ultra-fine oil aerosols; removes solid particles to 0.01 micron (0.001 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * First stage: coated, closed cell foam sleeve acts as pre-filter and flow disperser * Second stage: multiple layers of matrix blended fiber media for ultra-fine coalescence Outer coated, closed cell foam sleeve 5). Oil vapor removal filter (HF1) For removal of oil and hydrocarbon vapors normally absorbable by activated carbon; removes solid particles to 0.01 micron (0.003 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * first stage: stabilized bed of finely divided carbon particles removes the majority of the oil vapor * Second stage: multiple layers of fiber media with bonded micro fine carbon particles remove the remaining oil vapor Multiple layers of fine media prevent particle migration Outer coated, closed cell foam sleeve prevents fiber migration Designed life is 1000 hours under rated conditions.
Air dryer(desiccant air dryer) hsd-10wxf Desiccant compressed air dryer (heatless purge and externally heated purge) 1). Heatless purge desiccant air dryer Inlet temperature: 0~45 celsius degree Inlet oil content: 0.01ppm Working pressure: 0.6~1.0mpa Dew point: -20~-70 celsius degree Purge air: 12% Desiccant: activated alumina & molecular sieve Purge mode: heatless purge Working method: continuing alternation between two towers Working periods: t=10~20min. Control mode: micron computer auto controlling Installation mode: indoor, non-basement 2). Externally heated purge air dryer Inlet temperature: 0~45 celsius degree Working pressure: 0.6~1.0mpa Dew point: -40~-70celsius degree Purge air: 4~6% Desiccant: activated alumina & molecular sieve Purge mode: externally heated purge Working method: continuing alternation between two towers Working periods: t=120~140min. Control mode: micron computer auto controlling Installation mode: indoor, non-basement
Sterile filter * adopt 6 grades element which complement with America UPS plastic biology * element material is SPF who is good at hydrophobe, precision to be 0.01um.It can filter bacterium, virus & phagocyte. * o ring seal (silica rubber and fluorine rubber), ensuring to filter air 100%. * unique outer heat-resistant polypropylene.It can stand 140 celsius degree steam bacterium removal and will not reduce its precision if repeat sterilizing. * stainless steel of housing, polishing of internal, max.Working pressure to be 1.0mpa. * operation temperature less than 80 celsius degree .
Inlet pressure: 0.6~1.0Mpa Inlet temperature: 5~65 celsius degree Initial pressure drop: less than 0.005Mpa Filter route: 5um Water removal rate: less than 99% Outlet air oil content: less than 10ppm
Low Dew Point Combined Compressed Air Dryer Working pressure: 0.6~1.0Mpa Pressure drop: less than 0.05Mpa Inlet temperature: less than 45 celsius degree (Normal temp. type) Inlet temperature: less than 80 celsius degree (High temp. type) Dew point: -40~ -70 celsius degree Cooling watre temperature: less than 32 celsius degree (water cooling type) Purge air: 3~5% Control mode: Micro-program controller Installation mode: Indoor, non-basement
Desiccant Compressed Air Dryer two types ---heatless purge and externally heated purge 1). Heatless purge desiccant air dryer Inlet temperature: 0~45 Celsius degree Inlet oil content: less than 0.01ppm Working pressure: 0.6~1.0Mpa Dew point: -20~-70 Celsius degree Purge air: less than 12% Desiccant: Activated alumina & molecular sieve Purge mode: Heatless purge Working method: Continuing alternation between two towers Working periods: T=10~20min. Control mode: Micron computer auto controlling Installation mode: Indoor, non-basement 2). Externally heated purge air dryer Inlet temperature: 0~45 Celsius degree Working pressure: 0.6~1.0Mpa Dew point: -40~-70 Celsius degree Purge air: less than 4~6% Desiccant: Activated alumina & molecular sieve Purge mode: Externally heated purge Working method: Continuing alternation between two towers Working periods: T=120~140min. Control mode: Micron computer auto controlling Installation mode: Indoor, non-basement
Aromatic Diffusers
Aromatic Diffusers