Non-flooring material: DIN54837 and ISO 5659-2 FED Toxicity for S2-S5,SR1/SR2,ST1/ST2 Flooring covering: ISO9239-1 for SF1-SF3 and ISO 5659-2 FED toxicity Small Parts: DIN53438-2 / DIN53438-3 for K1-K3 or F1-F3 Seats: DIN 54341 EN1021 ISO9705 Cable and Wire: EN 60332-1-2 EN50266-2-4/5 EN 6103 EN 50305 Small Electrical parts: EN 60695-11-10 ISO4589-2 - Test method > DIN 54837: Small Parts combustion test > EN ISO 9239-1: extension of the flame test - Floor > DIN 53438-2: Flammable Material Testing > DIN EN 60332-1-2: single cable Vertical Burning Test > DIN EN 61034-1: Wire & Cable Smoke Density Test > DIN EN 50266-2-4: Vertical Burning Test for punch cable > DIN EN 1021-1: Seat Burning Test > DIN EN ISO 5659-2: Smoke Toxicity Test We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behavior of materials and parts, classification, requirement and test methods BS6853 Code of practice for fire precautions in the design and construction of passenger carrying trains NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material
TB/T 3237 Chinese Fire test standard for railway vehicles TB/T 3237 Chinese Fire test standard for railway vehicles - Standard TB/T 3237 Flame retardant technical specification of decorating materials for multiple unit train TB/T 3237 Chinese Fire test standard for railway vehicles â?? Test Method GB 2406 Oxygen index test UIC 564 Combustion test GB 8323 Smoke density test TB 3237 Part 4.4 Smoke toxicity test TB/T 3237 Chinese Fire test standard for railway vehicles â?? Scope This Standard is applicable to the flame retardant decorating materials for the multiple unit train with an operation speed larger than or equal to 200km/h. This Standard specifies the flame retardant property requirements and test methods for the decorating materials for multiple unit train. TB/T 3237 Chinese Fire test standard for railway vehicles â?? Reference Standard GB/T 2406.2 Plastics - Determination of Burning Behavior by Oxygen Index GB/T 10707 Rubber - Determination of the Burning GB/T 8323.2 Determination of Optical Density by a Single-chamber Test UIC 564-2 Regulations relating to fire protection We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behaviour of materials and parts, classification, requirement and test methods BS6853 Code of practice for fire precautions in the design and construction of passenger carrying trains NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material CASfire Technical Co.,Ltd 8F Building 4, Chinese Academy of Science, No.255 South Duiying Road,Jimei, Xiamen 361021, China Tel: (+86) 0592-3500085 MP: (+86) 18906059211 Email: info@casfire.cn Website: http://www.casfire.cn
EN 45545-2 New Fire test to railway vehicles - European Standard EN 45545-2:2013+A1:2015: Fire protection of railway vehicles - Part 2: Requirement for fire behaviors of materials and components Scope This part of EN 45545 specifies the reaction to fire performance requirements for materials and products used on railway vehicles as defined in EN 45545-1. For each hazard level, this part specifies the test methods, test conditions and reaction to fire performance requirements.It is not within the scope of this European Standard to describe measures that ensure the preservation of the vehicles in the event of o fire. Hazard levels HL1, HL2, HL3 Test Method EN 45545-2 R1: Surface Products EN 45545-2 R10: Flooring Covering EN 45545-2 R15, R16: Wire & Cable EN 45545-2 R22/ R23: Interior seals, Electrical Equipment EN 45545-2 R24 : Electrotechnical products EN 45545-2 R24/R25 : PCB Printed circuit boards EN 45545-2 R26 : Small electrotechnical products Reference Standard EN 45545-1: Fire Protection of railway Vehicles â?? Part 1: General EN 45545-2: Requirement for fire behaviour of materials and components EN 45545-3: Fire resistance requirements for fire barriers and partitions EN 45545-4: Fire safety requirements for railway rolling stock design EN 45545-5: Fire safety requirements for electrical equipment EN 45545-6: Fire control and management system EN 45545-7: Flammable liquid and flammable gas installations We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behaviour of materials and parts, classification, requirement BS6853 Code of practice for fire precautions in the design and construction NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material CASfire Technical Co.,Ltd 8F Building 4, Chinese Academy of Science, No.255 South Duiying Road,Jimei, Xiamen 361021, China Tel: (+86) 0592-3500085 MP: (+86) 18906059211 Email: info@casfire.cn Website: http://www.casfire.cn
EN 45545-2:2013+A1:2015: Fire protection of railway vehicles - Part 2: Requirement for fire behaviors of materials and components This part of EN 45545 specifies the reaction to fire performance requirements for materials and products used on railway vehicles as defined in EN 45545-1. For each hazard level, this part specifies the test methods, test conditions and reaction to fire performance requirements.It is not within the scope of this European Standard to describe measures that ensure the preservation of the vehicles in the event of o fire. Hazard levels HL1, HL2, HL3 Test Method EN 45545-2 R1: Surface Products EN 45545-2 R10: Flooring Covering EN 45545-2 R15, R16: Wire & Cable EN 45545-2 R22/ R23: Interior seals, Electrical Equipment EN 45545-2 R24 : Electrotechnical products EN 45545-2 R24/R25 : PCB Printed circuit boards EN 45545-2 R26 : Small electrotechnical products We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behaviour of materials and parts, classification, requirement BS6853 Code of practice for fire precautions in the design and construction NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material CASfire Technical Co.,Ltd 8F Building 4, Chinese Academy of Science, No.255 South Duiying Road,Jimei, Xiamen 361021, China Tel: (+86) 0592-3500085 MP: (+86) 18906059211 Email: info@casfire.cn Website: http://www.casfire.cn
fire test range of products 1. BS 6853 - Table 1: Interior horizontal supine surfaces 2. BS 6853 - Table 2: Interior vertical surfaces 3. BS 6853 - Table 3: Interior horizontal prone surfaces 4. BS 6853 - Table 4: Exterior horizontal supine surfaces 5. BS 6853 - Table 5: Exterior vertical surfaces 6. BS 6853 - Table 6: Exterior horizontal prone surfaces 7. BS 6853 - Table 7: Interior minor use materials of mass 100g to 500g 8. BS 6853 - Table 8: Exterior minor use materials of mass 400g to 2000g 9. BS 6853 - Table 9: Seat trim 10. BS 6853 - Table 10: Seat shell (back and base) 11. BS 6853 - Table 11: Textiles (free standing and lying) 12. BS 6853 - Table 12: Mattresses 13. BS 6853 - Table 13: Interior cable 14. BS 6853 - Table 14: Exterior cables We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behaviour of materials and parts, classification, requirement and test methods BS6853 Code of practice for fire precautions in the design and construction of passenger carrying trains NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material CASfire Technical Co.,Ltd 8F Building 4, Chinese Academy of Science, No.255 South Duiying Road,Jimei, Xiamen 361021, China
Fire Extinguisher Ball Introduction: The introduction consists of fire extinguisher ball specification principle, installation instruction etc. The product can put out A,B,C,E,F class fire. When the fire happens in home, supermarket, hotel and bar, many big fire extinguishing devices can not put out the fire in time, many fire extinguishing devices need to be used by people who has got some professional training. Aiming to these issues, we develop a new fire extinguishing device---fire extinguisher ball. With small size, light weight and ball appearance, I t can close and put out the fire in time. Even the old people and children can use it easily. The fire extinguisher ball doesnt need maintenance, which will save a lot of money for you .The life of product is 5 years .The noise can remind people to leave or come to fight the fire when dry powder fire extinguisher ball device is putting out the fire. The production and test standard of dry powder fire extinguisher ball device is Q/0900 TGT0012015. 1ï¼?Structure 12 Box= 1 piece (bracket+ screws included) Carton= 12 pieces (bracket+ screws included) Box dimension: 18cm*18cm*18cm Carton dimension: 56cm*38cm*38cm 20ft container= 4320 pieces= 360 cantons( bracket+ screws included) 40ft container= 9072 pieces=756 cantons( bracket+ screws included) MOQ:120pcs OEM MOQï¼?3000pcs
Rated working pressure: 0.5Mpa working pressure: 0.3-0.7Mpa Mixed flow rate / water output: 400L/min Foam output: 1.5m3min Foam distribution: >15m dimension: 500*180*180mm Gun diameter: 60mm
Certification: portable air foam spraying gun is in accordance with the IMO"international code for fire safety system. SOLAS 1974, as amended.In accordance with GB/T3571. Rated working pressure: 0.5Mpa working pressure: 0.3-0.7Mpa Mixed flow rate: 400L/min Water output: 400L/min Foam output: 1.5m3min Foam distribution: >15m
Introduction: Included the following items 1, Helmet 2. Clothes 3. Trouses 4. Belt 5. Fire proof Boot 6. Gloves Description strengthed the shoulder, elbow, knee. Hem with large pockets, pocket bottom corners have a water drain hole. Reflecting sign belt, seam, sleeve seam, batwing joints in main stitch are double needle, and using the Fang anti- temperature line. Cuff trousers, leather bags, waterproof rib cuffs, and a thumb ring buckle design, rib cuff material for aromatic fiber. Elastic belt use strong elastic rubber band. Garment fit, with high protection grade, ightweight non-removable integrated fire protective clothing Specifications 1. EN469 SRO fire-proof fabrics fire suit/firefighter suit for fireman 2.Application: Used for protection for firemen Clothing Construction: Jacket Material: Composite cloth with fire resistant layer, waterproof and breathable layer, heat protective layer, comfortable layer Reflective band; American 3M company Color: Purplish blue Characteristics: 1. Fire Resistance Performance: Damaged Lengthâ?¤ 10cm Continued Burning Timeâ?¤ 2s 2. TPP(heat protective performance)â?¥ 28cal/cm2 3. Weightâ?¤ 3.5kg/set 4. Breathable capacity â?¥ 5000g/square meter 24h 5. Anti-static water-pressure â?¥ 17000PA Material: Out: SRO fire-proof fabrics XBD(210±10.5)g/m2 Moisture Barrier: Non-woven Aramid + PTFE(105±10)g/m2 Thermal Barrier: Retardant Insulation Blankets 716# (150±20)g/m2 Pillow top: Cotton Muslin (120±12)g/m2 32*32 75*75 Dupont Reflective Strip Standard: EN469 ZGZ-ZPJY-001:2009 & GA10-2002
Size: 620*590*525mm Weight: 70kg Max power: 13hp Max capacity: 47.5t/h Presseure: more than 0.5mpa
Size: assorted Material: stainless steel / Q235
Coupling type: Nakajima Nominal diameter: 40mm, 50mm, 65mm Material: rubber, aluminum Suitable medium: water
DESCRIPTION Type: PP24C Service Pressure: 0.5-1.0MPa Max Service Pressure: 1.0mpa Spray Capacity: mixed liquids 24l/s, water24l/s Range: more than 40m Horizontal rotary: more than +- 180degrees Max angle of elevation: more than +- 70 degrees Max angle of depression: less than -60degrees Allowable error of discharge capacity: +- 8% Foaming times(at 20degree): more than 6 25% discharge time(at 20 degree): more than 2.5min Effluent capacity: 85T/H Connection Flang: DN80
Technical: ship-proof, stab-proof,acid and alkali-resistant
SCBA comply with IMO MSC.339.(91) resolution amendment "International Fire Safety System" (FSS code)
DESCRIPTION Introductions: 1.firefighting equipment Approval:ABS,CCS,BV,DNVetc 2.fire fighting equipment material :stainless steel 3.Capacity of fire monitor/fire pump : 160m3/h,180m3/h ,360m3/h ,600m3/h , 900m3/h , 1200m3/h , 3600m3/h ,etc 4.firefighting equipment Type:Supply external Fire Fighting Systems , FiFi1/4,FiFi1/2, FiFi 1, FiFi 2 , etc 5.Fire Fighting System Engine:Cummins Engine or the demands you need 6.Fire fighting equipment Include:fire pump,fire monitor,with diesel Engine 7.Firefighting equipment color:red Technical Parameters for Maritime Fire Fighting Fifi 3/ Firefighting 1 And 2 Firefighting Class System. 1.FiFi Class 2 System 7200m3/h Diesel Engine Driven Fire Pumps: 2X3600m3/h Fire Monitors:4X1800m3/h@150m, Remote Control System 2.FiFi Class 1 System 2400m3/h Diesel Engine Drivenor Electric Motor Driven Fire Pumps: 2X1200m3/h or one 2400m3/h Fire Monitors:2X1200m3/h@120m Remote Control System 3..FiFi 1/2 System Diesel Engine Driven or Electric Motor Driven Fire pumps: 1200m3/h Fire Monitors:2X600m3/h@120m or1X1200m3/h@120m Remote Control System 4.None Classed Fi-Fi System Diesel Engine Drivenor Electric Motor Driven Fire pumps:2X300m3/h@145m Fire Monitors:2X300m3/h@85m 5. None Classed Fi-Fi System 6.Fire Pump Unit, fire pumpCapacity: 4200m3/h,3600 m3/h, 2400 m 3/h, 1800 m3/h, 1200 m3/h, 600 m3/h, 300 m3/h,250 m3/h ,ect Certificate: CCS BV ABS DNV and other Class 7. Fire monitor Including fire water monitor , foam monitor , powder monitor with Electric/hydraulic romote control and hand whell REMARK:Designated the best solution for you,according to your requirements. Above just for your guidence. If you need this products For ship,pls provide the below information for external Fire Fighting Systems 1. Capacity of the Fire monitor for this Fire Fighting Systems (m3/h) 2. Fire pump Capacity for Fire Fighting Systems(m3/h) 3.Need the diesel Engine for fire pump 4.Any special brand demands for diesel fire pump engine Related pictures Maritime Fire Fighting Fifi 3/ Firefighting 1 And 2fir Firefighting Class System(fire monitor,fire pump,diesel engine for firefighting equipment)
Fire Extinguishing Ball is a fully automatic fire extinguisher. When throw into or rolling to fire, it will explode and make huge noise to catch everyone's attention nearby. You can also place it where the hot spots are such as flammable objects, circuit breaker box and gas tank. In case of fire, it will put out the fire by itself thus guarding lives and property. Features: * Reaction time: 3-5 seconds * Auto spray/manual * Everyone can be easy to use * High security * Environmental harmless dry powder and safe for users * No need to do regular inspection every year, the life span is 5 years Descriptions: * Product name: AFO fire extinguisher ball * AFO HS: 842410000 * Instruction: Fixed position by automatic fire sensor and/ or throw in fire area * Content: Environmental harmless dry powder * Automatic reaction time: 3-5 seconds * Effective extinguish area: 3 m3 * Validity: 5 years * Shape: ball type * GW: 1.3~1.5kgs If you would like to get more information of fire extinguisher ball, fire extinguisher, fire ball, AFO; please contact us by email. All business inquires are replied within 24 hours. Welcome to order by OEM and ODM!
Fangzhan SCBA Features and BenefitsFangzhan combined proven concepts to develop a better SCBA - an SCBA that, after every design change, was taken back to firefighters like you for testing and to make sure it was right. The result of hundreds of hours of design, engineering, and testing: an innovative way to think about the SCBA, placing the firefighter at the center of the design process. Specifications,TypeOpen-circuit pressure demand self-contained breathing apparatus,Facepiece MaterialButyl rubber,Head HarnessSilicone or Kevlar,AlarmsBell, plain whistle or warbling whistle,Second Stage RegulatorPilot valve,Heads-Up DisplayLED style,Cylinder Pressures2216 or 4500 psig,Cylinder Durations30-, 45- or 60-minutesRecommended Industries/Use,Fire Protection,Forestry,Government,Military,Mining,Municipal Services,Nuclear,Oil and GasHazards,Airborne Particulates,Biohazard,Chemical,Confined Space,Contamination,Extreme Environment,Explosion,Fire,Gas, Vapors, Smoke,Welding FlashRegulations,EN136 EN137 ,MSC339 (91)
I.SummarizeAs individual protective equipment for personnel respiratory, , gas defence mask (Type:FZFD) canprotect the respiratory organ ,eyes and facial skin. Masks can be directly connected with the canister, or connect with the canisters with the airway. FZFD type gas mask can choose different sizes canisters according to the different protection requirements. Its used  for military, factories and mines, scientific research, ambulance, fire and other units.It meets the standard of GB2890-95.II.BodyThe body with an inner periphery and chin off the cover is made of black rubber molded ,which ensureadhesion with the face and comfortable to wear. This rubber is specially formulated to enhance the life of the mask and the skin without irritation. Easy to adjust the belt, it can quickly wear. Therefore, the gas mask can ensure airtight, and comfortable to wear in all cases, even when engaged in intense activity.III.Specification1. Protection objects: according to needs of different canisters,it can protect people from toxic gases, vapors and toxic smoke.2. Expiratory resistance: not more than 90 Pa (30 l / min)3. View: no less than 70% of the total field of vision, double vision is no less than 30%4. View Performance: when longer than 1.5 hours, without fogging the lens, without distortion anddeformation (-30 )5. Tightness:( Mist leak tightness factor): not more than 0.005%
Descriptioneebd is a compressed air emergency escape breathing device designed to offer easy donning, , combined with optimal respiratory protection. It is contained in a bag for carrying which, when opened, automatically triggers the supply of breathable air from the cylinder. Overpressure maintained inside the hood eliminates any risk of inhaling toxic gases. The hood is adjusted automatically thanks to the integrated inflatable air cushion on the back of the head. This system allows the hood to fit securely over the head, offering greater respiratory comfort and leaving the hands free during donning, ensuring the highest level of safety. An alarm whistle indicates when the air supply is about to run out. Supplied with 3L steel cylinderThe unexpected release of noxious gases, vapors, fumes or other toxic airborne materials cannot be absolutely eliminated from every industrial setting. Nevertheless, every industrial setting can be easily equipped with ELSA Emergency Escape Breathing Devices. Placed in strategic locations, EEBD provides exceptional breathing protection for emergency escape from those areas where hazardous conditions may suddenly occur.EMERGENCY ESCAPE BREATHING DEVICES Very Simple to operate starts automatically upon opening of bag Easy to rechargeable and reusable 15 minute versions available ISO23269 & EN1146ParametersModel: TH/15-1Duration: 15 minutesTotal dimensions: 590*250*175 mmWeight : 7.0KGApproval: ECÂ Product TypeRespiratory ProtectionRangeSCBA (Self Contained Breathing Apparatus)LineCompressed airline filtration systemsBrandFangzhanIndustryChemical IndustriesPetro-chemical