SCT range of split core current transformers have been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. An ineternal precision resistor across the secondary winding of the ct provides a low safe voltage output.
DASN series three phase current transformer development of DAS series,use it in primary current 60A-1600A electric circuit , Supporting the use of plastic shell breaker.
D363 & D364 range of current transformers are combination designed 3 CT in 1, save more space comparing general unit CT, suitable for primarycurrent 75A to 600A, supporting the use of molded case circuit breaker according to the rated current size.
Epoxy Potting,Double-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
.Power quality monitoring .Power instrument and meter .Distributed measurement systems .Measurement of current of power supplyequipment below 10KV .Microcomputer protection Character: .Use high permeability silicon steel . Outdoor , water proof IP65,dust proof .Secondary winding employ with high qualityepoxy resin casting in plastic case which is flame retardant, anti-moisture,stable performance .Split core and full sealed ,use sealedwater proof cable as secondary leading wire
UK Series split-core current transformer has been specially designed to facilitate their installation in new or already existing networks. They may be installed without opening any cable or bus-bar circuit.An internal precision resistor across the secondary winding of the CT provides a low safe voltage output.It can save time and the installations costs. Features Doubie-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Application Current measurement,monitoring and protection for electrical wiring and equipment. Current and power measurement for electric motors,lighting,air compressor,heating and ventilation system,air-condition equipment and automation-control system. Current,power and energy monitoring device. Relay protection device
Rct range of current transformers can be applied to test, control, display and record the running of the electrical Equipment, and to protect the equipment against the damage, in the ac circuit with the rated voltage value below 720v and the Frequency of 50-60hz.The product can be also applied to form a complete set of mine transformer. Rct have larger capacity. With the method of fixed installation. Feature 1:safe, easy to install, portable 2:wide inner window, allowing clamping of big cables or bus-bars 3:wide range of sizes to accommodate all the existing installation. Applications : 1:current measurement, monitoring and protection for electrical wiring and equipment. 2:current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, 3:current, power and energy monitoring device. 4:relay protection device
Lmk3 range of current transformers can be applied to test, control, display and record the running of the electrical equipment, And to protect the equipment against the damage, in the ac circuit with the rated voltage value below 720v and the frequency of 50-60hz. The product can be also applied to form a complete set of mine transformer Features: 1:safe, easy to install, portable 2:wide inner window, allowing clamping of big cables or bus-bars 3:wide range of sizes to accommodate all the existing installations Applications: 1:current measurement, monitoring and protection for electrical wiring and equipment. 2:current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, Air-condition equipment and automation-control system. 3:current, power and energy monitoring device. 4:relay protection device
Rlc range of current transformers advanced snap on body, high accuracy (up to class 0.2s), Humanization transparent cover and lead seal holedesign makes the ct very easy to indentify after long term use , And perfect anti-stealing electricity. Feature: 1:built in hinged terminal cover 2:built in transparent cover for name plate 3:wide range accuracy (3, 1, 0.5, 0.5s, 0.2, 0.2s) 4:primary current from 5a to 5000a.Enables meet the worldwide requirement. Applications: 1:current measurement, monitoring and protection for electrical wiring and equipment. 2:current and power measurement for electric motors, lighting, air compressor, Heating and ventilation system, air-condition equipment and automation-control system. 3:current, power and energy monitoring device. 4:relay protection device
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
copper Aluminum 1455
Electrical transformer.
Transformers.
All types of electrical distribution transformer dry and oil type.
Electrical Transformers.
Transformers.
Current Transformers.
Power and Distribution Transformer (100 to 500KVA).Importer, Manufacturer
Transformers.