A transformer is an electrical device which is used to transfer power from one circuit to another through electromagnetic induction. The power transfer is accompanied without frequency change. In an electronic system, the term power transformer is used to provide a number of AC supplies of several voltages and appropriate values of current from the public electricity supply. Tungwell oil immersed transformers are up to 750kV, 1500MVA and cast resindry type transformers are up to 110kV, 40MVA. Our design team has very strong design capabilities and uses a variety of design software including 2D and 3D electrical field FEM and Magnetic flux leakage calculators. The resulting products come with many advanced features such as low loss design, short circuit withstand assurance, reliable extra-high voltage protection with overheating controls. The range of small power transformers can be from500-7500kVA The range of medium power transformers can be from-100MVA The range of large power transformers can be from100MVA & beyond
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Current ) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A 1.5 50 30 200 7.5 500 10 3 50 60 200 15 500 10 5 50 100 200 25 500 10 10 50 200 220/380 50/26 500 10
Product specifications Rated power: 2500kVA Voltage: 22/0,4kV Winding connection: Dyn11 No-load loss (Po): 1850 W Short-circuit loss(Pk): 21000 W Max. no-load current(I0): 1.5% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
1. Inverter duty Solar transformers, suitable for solar load profile. 2. Multi-winding (2 to 6 windings), oil-filled or dry type. 3. 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV. 4. Low-loss, with Aluminum or Copper winding. 5. Electrostatic shield between LV and MV Winding. 6. Fully type tested at internationally recognized laboratory. 7. Designed with high efficiency, environmental friendliness, superior operational reliability and minimal Total Cost of Ownership. 8. Ideally suited for large MW scale solar PV plants.
Product specifications Rated power: 2500kVA Voltage: 22/0,4kV Winding connection: Dyn11 No-load loss (Po): 1850 W Short-circuit loss(Pk): 21000 W Max. no-load current(I0): 1.5% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Currentm) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A YD G1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G 5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G 20 20 50 400 380 53 500 10 YD G 30 30 50 600 380 79 500 10 YD G 40 40 50 800 380 105 500 10 YD G 50 50 50 1000 380 132 500 10