H-Pylori Rapid Test HIV 1/2 Rapid Test HbsAg ( One Step Hepatitis B Antigen Test Device ) HbsAb ( One Step Hepatitis B Antibody Test Device ).
Consisting of Battery Handle 3 Ear Specula, 1 Bulb 3 Ear Specula, 1 Nasel Specula, 2 Laryngeal Mirrors With Holder 1 Tongur Depressor Holder, 1 Bulb.
It can detect the early pregnancy, and can be determined 2 to 3 days after the implantation of zygote with the interpretation of results for 3 to 5 minutes. Products is in various form with human oriented design and is suitable for all levels of medical units and home self-test. It is stored at room temperature, easy to carry, and valid for 24 months. Sensitivity: 25 mIU/ml. Specificity: the test results are not interfered by HLH, HFSH, HTSH and so on in a certain concentration. Strip: 100pcs/bag,5000pcs/carton 100pcs/box,5000pcs/carton Cassette: 50pcs/bag,2000pcs/carton 50pcs/box,2000pcs/carton Midstream: 50pcs/bag,2000pcs/carton 1pc/box,500pcs/carton.
50% advanced and 50% the after shipment. Stranded lot size.
Items of analysis (11) : glucose (GLU) , bilirubin (BIL) , specific gravity (SG) , PH, ketone (KET) , occult blood (BLD) , protein (PRO) , urobilinogen (URO) , nitrite (NIT) , leukocytes (LEU) , ascorbic acid (VC) Wavelength: 510nm-650nm Testing speed: 120 samples per hour Storage: automatic storage up to 1000 items of patients¡¡£¤ data Display: 240*64 graphic LCD Printing: internal 57mm thermal printer Interface: RS232 standard computer interface Language selection: Chinese / English Working environment:temperature:15-35¡æ,humidity: 10-80% Power supply: AC 220V¡¡§¡è10%, 50Hz-60Hz,100w Box dimension: 470¡¡§¡é400¡¡§¡é238(mm) Gross weight: 7kg. Power supply: AC 220V¡¡§¡è10%, 50Hz-60Hz,100w Box dimension: 470¡¡§¡é400¡¡§¡é238(mm) Gross weight: 7kg
We have good quality blood grouping kit and other widal , RA , ASO , CRP. We assure you good quality & good price.
Body size 2.5 x 8 2.4 orgnal display panel 218g with Two battries Image freze Function Video out port.
Our product is based on the theory of enzyme interaction. It is used to detect the content of FSH atom in urine speciment. The colour change could identify the result directly. Assisting with the result, doctor could judget whether the patient is pregnant or not. 2.5mm, 200 strips/pouch, 10,000strip /case ,27kg 3.0mm, 50 kits/ pouch, 2,000 kits/case, 27kg 4.0mm, 150 cards/pouch, 2,500 cards/case, 25kg 5.0mm 10000strips/case 2000kits/case 2500cards/case.
Blood glucose test strip. 50 test strip.
Glucose test strip. 50 test strip.
1. Display SpO2 waveform, SpO2 /PR bar graph 2. Digital technology, Accurate measurement during low perfusion 3. Color LCD display screen with four display modes 4. Visual Alarm function 5. Compact design & single button operation design 6. Anti-Movement, stable performance 7. Power-save function.
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: ín1.5 minute per sample Up to 100, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing, block clearing Color lcd display 272mm(l)íß 420mm(w)íß 390mm(h) 24kg
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
Fully automated, compact, flexible and low cost 3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: 60 samples per hour Automatic diluting, lying, mixing, rinsing and clog-clearing Automatic sample probe cleaning Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Reagent expired alarm Color lcd display 40cm(l)40cm(w)46cm(h) 25kg
12 predetermined animals + 4 options, Wbc 3 part diff 19 parameters + 3 histogram 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
80 samples per hour--- Fully auto cap piercing sampler--- Sample rotor valve technology--- Parameters: 19 parameters + 3 histograms Principle: electrical impendence for counting and sft method for hgb Throughput: up to 80 samples per hour Sampler capacity: 50 samples Testing mode: manual open(whole blood, prediluted); sampler close(whole blood) Sample volume: sampler mode: whole blood 200 ª8l Manual mode: whole blood 200ª8l; prediluted 40ª8l Aperture diameter Wbc: 100ª8m Rbc/plt: 80ª8m Memory: 35, 000 results with histogram Performance: Parameters precision cv% Wbc(10 /l) 2.0% Rbc 1.5% Plt 4.0% Mcv(fl) 0.5% Hgb(g/dl) 1.5% Display Large color lcd, displays all parameters result with histogram of wbc, rbc and plt Resolution: 800íß600 Menu Count, sample mode, review, quality control, system setting, reference value, system service, calibration, copyright, shutdown Alert: 25 sets of alert message Input/output: usb(keyboard, mouse, flash disk), rs232, parallel Print:graphic thermal printer with various printing format, optional external printer Operating environment: Temperature: 18-30íµ Humidity: ín70% Power requirement: Ac100-240v, 60/50hz Dimension 600mm(l)íß520mm(w)íß57 0mm(h) Weight 30kg
Rapid HCG Pregnancy Test Card Intended Use HCG Pregnancy Urine Test is a chromatographic immunoassay for the early detection of human chrionic gonadotropin (HCG) in urine specimens. Contents of Kit HCG Pregnancy Test Card 25 ea Instructions For Use 1 ea Storage And Stability The kits should be stored at temperature 4-30ípC in the sealed pouch for the duration of the shelf life. Pre Cautions 1. For in vitro diagnostic use only. 2. Do not use after expiration date. 3. Test device should remain sealed until use. 25 tests/kit, 40 kits/carton
Rapid Malaria pf/pv Antigen Test Card Intended Use Malaria pf (HRP II) / pv (LDH) Antigen Test is for the rapid qualitative determination of Malaria P. falciparum specific histidine rich protein-2 (Pf HRP-2) and Malaria P. vivax specific lactate dehydrogenase (pvLDH) in human blood as an aid in the diagnosis of Malaria infection. Contents of Kit Malaria pf/pv Antigen Test Card 25 ea Malaria Sample Buffer 1 ea Instructions For Use 1 ea Storage And Stability The kit can be stored at room temperature or refrigerated (4-30ípC). The test device is stable through the expiration date printed on the sealed pouch. The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date. Pre Cautions 1. For professional in vitro diagnostic use only. Do not use after expiration date. 2. Do not eat, drink or smoke in the area where the specimens or kits are handled. 3. Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout testing and follow the standard procedures for proper disposal of specimens. 4. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are being tested. 5. Humidity and temperature can adversely affect results. 25 tests/kit, 40 kits/carton
Nabl accredited blood testing lab - complies with iso 15189- offers clinical research among others. Na
All of our products are ce, fda and iso 13485 certificated with competitive price (negotiable) and warranty in international market. Meanwhile, excellent services and prompt delivery help us win great fame among customers. 1. Convenient, reliable results, capillary action strips allow a quick and simple application of blood. In only 20 seconds, the meter produces an accurate reading. 2. Less painful results, requires only 3ul of blood and allows testing on forearm and palm. 3. Affordable results. Frequent testing helps improve control. 4. Information to better manage diabetes. Memory feature stores up to 30 tests and provides 7, 14 and 30-day averaging. One kit of glucose testing system includes all the following Biocare blood glucose meter 10 test strips (free) One adjustable lancet device 10 sterile lancets (free) Ownerí»s booklet One carrying case Two 3.0v lithium batteries (installed) Specifications Measuring range: 2.2-27.8mml/l (40-500mg/dl) Measuring time: 20 seconds Memory capacitance: 30 Power source: two replaceable 3-volt batteries (cr2032) Batteries life: > 1000 tests Life of test strips: 12 months (vial sealed), 3 months (after vial opened) Volume of blood: 3ul Net weight: 52g Dimensions: 97(l)*55(w)*15(h) mm Item: glucose meter and testing strip Model no.: sg-1 Description: 97(l)*55(w)*15(h) mm Package: color box Moq: 500pcs for meters , 1000bottles for strips(50strips/bottle) Ctn size: 72*58*54cm , 35*22*51.5cm Q'ty/20': 2100pcs; q'ty/40': 4200pcs Loading port: shanghai Payment terms: t/t in advance, l/c, etc. Valid time: 60 days