The Anti Sperm Antibody IgG GENLISA ELISA is intended for the qualitative determination of Anti-Sperm antibody IgG in human serum and plasma. Pack Size - ELISA 96 wells
The Anti Ovary Antibody IgM GENLISA ELISA is intended for the qualitative determination of Anti Ovary Antibody IgM in human serum and plasma. Pack Size - ELISA 96 wells
The Anti Cardiolipin IgG GENLISATM ELISA is intended for the qualitative determination of Anti Cardiolipin IgG antibody in human serum and plasma. Pack Size - ELISA 96 wells
The Anti-Cardiolipin IgA GENLISATM ELISA is intended for the qualitative determination of Anti Cardiolipin IgA antibody in human serum and plasma. Pack Size - ELISA 96 wells
The ANA GENLISA ELISA is intended for the qualitative screening of anti-nuclear IgG antibodies in human serum and plasma.
The Toxoplasma gondii IgM GENLISA ELISA is intended for the qualitative determination of Toxoplasma gondii IgM antibody in human serum and plasma. Pack Size - ELISA 96 wells
The Rubella IgM GENLISATM ELISA is intended for the qualitative determination of Rubella Virus IgM class antibodies in human serum and plasma. Pack Size - ELISA 96 wells
The Rubella IgG GENLISATM ELISA is intended for the qualitative determination of Rubella Virus IgG class antibodies in human serum and plasma. ELISA 96 wells
The HSV 1 & 2 IgG GENLISA ELISA is intended for the qualitative determination of HSV 1 & 2 IgG in human serum and plasma. Pack Size - ELISA 96 wells
The HSV 1 IgM GENLISA ELISA is intended for the qualitative determination of HSV 1 IgM in human serum and plasma.
The HSV 1 IgG GENLISA ELISA is intended for the qualitative determination of HSV 1 IgG in human serum and plasma. Pack Size - ELISA 96 wells
The CMV IgM GENLISA ELISA is intended for the qualitative determination of CMV IgM in human serum and plasma. ELISA 96 wells
The Varicella-Zoster Virus (VZV) IgM ELISA is intended for the qualitative determination of IgM class antibodies against Varicella-Zoster Virus (VZV) in human serum or plasma (citrate, heparin). ELISA 96 wells
The Varicella-Zoster Virus (VZV) IgG ELISA is intended for the qualitative determination of IgG class antibodies against Varicella-Zoster Virus (VZV) in human serum or plasma (citrate, heparin).
The HEV IgM GENLISA ELISA is intended for the qualitative determination of Hepatitis E Virus IgM in human serum and plasma.
The C-Reactive Protein Semi-Quantitative Rapid Test Device (Whole Blood/Serum/Plasma)is a rapid chromatographic immunoassay for semi-quantitative detection of C-Reactive Protein in whole blood, serum or plasma specimens to aid in evaluating risk of cardiovascular disease.
The CK-MB Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human CK-MB in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI).
Gut health is very important in order to maintain healthy life. The gut microbiome test which can be taken in the comfort of your home can reveal any imbalance in your gut flora. You can take corrective action to reduce your risk of diseases like Irritable Bowel Syndrome, diabetes, obesity, depression and hypertension caused by an unhealthy gut.
Product Name Human Chorionic Gonadotropin (HCG) Test Kit (Immunofluorescence Chromatography) Purpose To detect the content of HCG in human plasma/serum/whole blood in vitro quantitatively.For Professional Use only. Principles of Detection The HCG Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing HCG antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another HCG antibody, and the C line is pre-coated with a control line antibody (chicken IgY antibody). HCG concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of HCG according to the preset calibration curve in the machine and display the result, detection unit is mIU/mL. C line should appear in any cases, which indicates the reaction system is effective. Storage conditions and shelf life Store in a sealed aluminum foil bag at 2 - 30 C. After unpacking the aluminum foil bag under temperature 20~30 C , humidity 35~65%, please use it immediately. Shelf life 18 months. Applicable instrument Avid fluorescent immunoanalyzer model: AI-IF 600
Product Name Triiodothyronine (T3) Test Kit (Immunofluorescence Chromatography) Purpose To detect the content of T3 in human plasma/serum/whole blood in vitro quantitatively.For Professional Use only. Principles of Detection The T3 Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing T3 antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another T3 antigen, and the C line is pre-coated with a control line antibody (chicken IgY antibody). T3 concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of T3 according to the preset calibration curve in the machine and display the result, detection unit is nmol/mL. C line should appear in any cases, which indicates the reaction system is effective. Storage conditions and shelf life Store in a sealed aluminum foil bag at 2~30�°C. After unpacking the aluminum foil bag under temperature 20~30 �ºC , humidity 35~65%, please use it immediately. Shelf life 18 months. Reference range Reference value:The 95% concentrations of T3 in 239 non-stationary subjects without any obvious thyroid dysfunction ranged from 1.34 to 2.73nmol/L, with a median of 1.81nmol/L;The reference value has been verified with reference to similar products already on the market. Each laboratory can build own reference range according to actual situation.