ECG software to import data from the ECG device EKG-3A EKG-3A ECG device Three Channel ECG machine ,Slim,advanced and light weight Large, Color and Touch Screen 7â??. Keyboard for Patient management, Name:____ . Age:____ . ID:_____ . Sex: M/F . Precise ECG auto-interpretation program. 12 lead ECG simultaneous acquisition and display. Simultaneous 3 leads ECG printing with 80mm thermal paper. Multiple operation mode: automatic, manual, arrhythmia analysis. Digital filters eliminate EMG, AC, Baseline Drift interference. Built-in rechargeable Li-ion battery, 2 hours continuous working. Real-time ECG waveform. External USB card store 1000 reports. Lead-off detection. Built in USB/RS232 interface. Software upgrade automatically via USB.
Cardios�® PC-based ECG provides you an affordable and portable 12-channel ECG solution with powerful data analysis functions. Optional advanced analysis functions secure clinical accuracy and maximum decision-making efficiency. Bluetooth Function available 12-Lead Simultaneous ECG Automatic Measurement and Interpretation Pacemaker Analysis Multi-Form Printing One Key Operation VCG and VLP Isolated USB PC Interface: USB Connector Patient Cable: 10 wires independent ( easy to remove) NEW Recording Speeding: 12.5mm/s 25mm/s 50mm/s Sensitivity: 10mm/mV 5mm/mV 20mm/mV Channel: 8 Heart rate indication Display range 30 to 300 bpm Display update with every heart beat maximum every 2 seconds. Data interface One USB interface for exchange of data with suitable external devices and software USB interface: output voltage range: 5V baseline Automatic adjustment of the baseline to the optimal recording range in dependence of the signal amplitude. Meditech PC ECG anti defibrillation & high-frequency protected
HeartTarang, a 12 lead medical ECG device meets all medical standards and generated ECG data with very high accuracy. All ambient and data transmission noise is filtered out.
Vesta 301i 3 Channel ECG Machine 12 lead simultaneous acquisition Graphical Colored TFT upto 3.5 inch for Real time ECG monitoring Measurements and Interpretation Full alphanumeric keypad Paper out Indication Multiple Printing options Isolation protection against defibrillation 50 patients memory storage USB storage (optional) Direct A4 ECG Printing (optional) PC connectivity (optional)
Compatible with BSM-2300, BSM-4100, BSM-2301, BSM-2353, BSM-5100, BSM-9510, BSM9800, Multi-parameter bedside monitors
1. Compatible with BR-913P, BR-903P, BR-906P 2. Connected with ECG trunk cable, so that to monitor the patient's ECG information, when connected with the monitor; 3. The male connector is made by injection molded, which is durable; And the outer material is made of soft TPU material, which is anti-allergic, anti-corrosion and easy to clean; 4. The products can be disinfected and reused. So it is very cost-effective.
1. Compatible with Multi-pot system fur serie SC6000, SC6002XL, SC7000, SC9000, Art.Nr. 3368391 (8.2ft). Art.Nr. 5950196(4.9ft) 2. Connected with ECG leadwire, so that to monitor the patient's ECG information, when connected with the monitor; 3. The male connector is made by injection molded, which is durable; And the outer material is made of soft TPU material, which is anti-allergic, anti-corrosion and easy to clean; 4. The products can be disinfected and reused. So it is very cost-effective.
Model Number: J309-23SA Brand Name: Biolight Connector: 12 pin Product Categories: Monitor accessories Place of Origin: Henan, China (Mainland) Compatible Model: M Series, M7000, M8000, M9000, M9500 Instrument Classification: Class II Cable Material: Medical TPU Cable Color: Gray Certificate: CE, ISO13485 Warranty: 12 months
5.0-inch high resolution Colour LCD screen. 12-lead simultaneous acquisition. Complete digital filters and self-adapting filtering. "One-touch" functional shortcut keys Built-in rechargeable lithium battery for Aprox. 3Hr continuous work Up to 300 seconds of rhythm analysis for better in arrhythmia diagnosis About 1.3kg , light in weight Automatic Measurement & Interpretation with latest Minnesota code, tested by CSE / AHA / MIT database ensures analysis accuracy. 3 report formats: simple report, median beat report and manual report. Massive local storage capacity up to 1500 files. Peripheral ports: USB, LAN port.
Electrode, ECG, 21mmx40mm, Pediatric, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
Single channel / color & touch screen 2.8 inch colorful 320x240 resolution tft touch screen. Touch keyboard (patient name, age, sex,?¦) Automatic and manual operations. Power supply: ac220v 10% dc 8.4 lithium battery. Ac, emg filters. Interpretation Exterior sd card, upgrade the storage to 1000 case. Usb interface Paper speed: Auto record: 6.25mm/s12.5mm/s25mm/s50mm/s, error: ,±5% Manual record: 6.25mm/s12.5mm/s25mm/s50mm/s, error: ,±5% Record 450 exam of ecg and review the stored cases and patient information anytime. Measurement parameters: hr, p-r interval, p duration, qrs duration, t duration, q-t interval, q-tc, p axis, qrs axis, t axis, r(v5), s(v1), r(v5)+s(v1). Sensitivity selections: 2.5, 5, 10, 20 mm/mv, 5 options , error:,±5%. Standard sensitivity is 10mm/mv,±0.2mm/mv . Comes with pc software for data transfer(save , review, print a report ) - reanalyze and ,??12 leads ecg - analysis items of ,??fcg,?�, ,??hfcg,?�, ,??qtd,?� and ,??hrv,?�, Multi languages
High-conductivity gel for electrocardiography (ECG) is a specialized conductive gel used to improve electrical conductivity between the skin and ECG electrodes during cardiac monitoring procedures. Here's more information about high-conductivity gel for ECG: Purpose: The primary purpose of high-conductivity gel is to reduce impedance and improve the transmission of electrical signals between the skin and the ECG electrodes. This ensures accurate and reliable recording of the heart's electrical activity during ECG testing. Composition: High-conductivity gel is typically water-based and contains conductive agents that enhance its electrical conductivity properties. Common ingredients may include water, glycerin, propylene glycol, carbomer, electrolytes (e.g., sodium chloride), and preservatives. Conductivity: High-conductivity gel is formulated to have superior electrical conductivity compared to standard ECG gels or other electrode contact solutions. This allows for better signal quality and minimizes the risk of artifacts or interference during ECG recordings. Viscosity: The gel's viscosity is designed to be suitable for easy application and spreadability on the skin. It should be thick enough to adhere to the skin and maintain contact with the electrodes but not too thick that it hinders electrode placement or skin contact. Non-Staining: High-conductivity gel is typically formulated to be non-greasy and non-staining, ensuring minimal residue on the skin after use. This helps maintain patient comfort and prevents staining of clothing or bedding. Compatibility: High-conductivity gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with standard ECG machines and Holter monitors. Application: Before applying the gel, the skin should be cleaned to remove any oils, lotions, or dirt that may interfere with electrode contact. A thin layer of high-conductivity gel is then applied to the skin at the electrode sites before attaching the electrodes. Hygiene: High-conductivity gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Overall, high-conductivity gel plays a crucial role in ensuring optimal electrode-skin contact and signal quality during ECG testing. Its superior conductivity properties make it an essential accessory in cardiac diagnostic procedures, allowing for accurate interpretation of the heart's electrical activity.
ECG gel, also known as electrocardiogram gel or EKG gel, is a conductive medium used in electrocardiography (ECG) procedures to improve the quality of electrical signal transmission between the skin and the electrodes of the ECG machine. Here's more information about ECG gel: Purpose: The primary purpose of ECG gel is to enhance the conductivity and reduce impedance between the skin and the ECG electrodes. This improves the quality and accuracy of the electrical signals detected by the electrodes, resulting in clearer and more reliable ECG readings. Composition: ECG gel is typically a water-based, conductive gel formulated to be non-greasy, non-staining, and hypoallergenic. It may contain ingredients such as water, glycerin, propylene glycol, carbomer, preservatives, and conductivity-enhancing agents. Conductivity: ECG gel is formulated to have high electrical conductivity, allowing it to effectively transmit electrical signals between the skin and the electrodes. This conductivity helps minimize impedance and artifacts, ensuring accurate ECG readings even in challenging conditions. Viscosity: ECG gel is usually designed to have a suitable viscosity that allows for easy application and smooth spreading on the skin. It should be thick enough to stay in place during the procedure but not so thick that it hinders electrode placement or skin contact. Compatibility: ECG gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with both standard ECG procedures and specialized cardiac tests such as stress tests, Holter monitoring, and echocardiography. Application: ECG gel is applied directly to the skin at the electrode sites before attaching the electrodes. A sufficient amount of gel should be applied to ensure good contact between the electrodes and the skin surface. Excess gel can be wiped away after electrode placement. Hygiene: ECG gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Removal: After the ECG procedure, any remaining gel should be wiped off the skin using a clean, dry cloth or disposable wipe. Residual gel left on the skin can cause discomfort or irritation if not properly removed.
An ECG bulb with an electrode cup is a component used in electrocardiogram (ECG) machines for detecting and recording the electrical activity of the heart. Electrode Cup: The electrode cup is the part of the ECG bulb that makes direct contact with the patient's skin. It is designed to provide a conductive interface for accurately capturing the electrical signals produced by the heart. Material: The electrode cup is usually made of metal or a conductive material that ensures good electrical conductivity and signal transmission. The bulb portion may be made of plastic or silicone, providing flexibility and durability. Compatibility: ECG bulbs with electrode cups are designed to be compatible with specific models of ECG machines. They may come in different sizes and configurations to fit various electrode placements and patient needs. Application: During an ECG procedure, the ECG bulb with an electrode cup is placed on the patient's chest, limbs, or other specific locations as directed by the healthcare provider. The electrode cup makes contact with the skin, allowing the ECG machine to detect and record the electrical activity of the heart. ECG bulbs with electrode cups are essential components of ECG machines, providing a reliable interface for capturing the electrical signals of the heart during diagnostic procedures. Their design, material composition, and compatibility with ECG machines make them valuable tools in cardiovascular healthcare settings.
An ECG bulb, made of silicone, is a component used in certain types of electrocardiogram (ECG) machines. Here's more information about ECG bulbs made of silicone: Material: ECG bulbs made of silicone are designed to be flexible, durable, and resistant to wear and tear. Silicone is chosen for its properties, including flexibility, biocompatibility, and resistance to temperature extremes and chemical exposure. Purpose: The ECG bulb, also known as an ECG electrode or sensor, is a crucial component of the ECG machine. It serves as the interface between the patient's skin and the machine's electrical circuitry, allowing the machine to detect and record the electrical signals produced by the heart. Design: ECG bulbs made of silicone typically have a bulbous or rounded shape with a flat surface that comes into contact with the patient's skin. The silicone material provides a comfortable and secure fit while ensuring good electrical conductivity for accurate signal transmission. Compatibility: Silicone ECG bulbs are designed to be compatible with specific models of ECG machines. They may come in different sizes and shapes to accommodate different electrode configurations and patient needs. Hygiene: Silicone ECG bulbs are often designed for single-use or disposable use to maintain hygiene and prevent cross-contamination between patients. Disposable ECG bulbs help reduce the risk of infection transmission in clinical settings.
ECG Machine-6
ECG Machine- 12
holter ECG lead cable
ECG 1200G 12-channel ECG is such a kind of electrocardiograph, which gathers 12-lead ECG signals simultaneously and prints out the ECG waveforms with thermal printing systems. Its users are mainly hospitals and all kinds of medical establishments. Main Characteristics: 800x600 dots high resolution color LCD. Convenient and quick button setup. Automatic/manual mode to record and display ECG waveform. Auto-measure of ECG waveform parameter.
3.5 TFT Color LCD Simultaneous 12 Leads display. Auto-analysis and auto-interpretation. Provide more than 10 printing modes. More than 1000 cases in internal memory. Can print 90 minutes and printout 150 pcs ECG continually