Dengue Combo
Malaria Antigen Kit
Pap Smear Kit
HBS AG
HCV Test Kit
A pregnancy test can confirm if a woman is pregnant. The test can be carried out at home or in the doctor's office. A pregnancy test is around 99 percent reliable. It works by measuring levels of a hormone called human chorionic gonadotropin (HCG). Categories - OTC - Over The Counter Product
I-can is a test kit, which helps to detect pregnancy. Every woman is excited to know whether she has conceived or not. This I- can kit will help you to confirm pregnancy. I-can detects pregnancy in five minutes. It confirms pregnancy by detecting the presence of human chorionic gonadotropin hormone (pregnancy hormone) in the urine. It gives an accurate estimation of pregnancy. Major benefit of this kit is that it is very simple to use and you do not require any assistance to determine pregnancy by using this kit.
Handheld Glucose, Lipid(TC, TG, HDL, Cal-LDL) Monitoring System The GREENCARE LIPID is an in vitro diagnostic medical device for measurements of total cholesterol, triglycerides, HDL cholesterol in whole blood by colorimetric assay with enzyme reaction. And the GREENCARE LIPID is an in vitro diagnostic medical device that can diagnose diabetes by measuring blood glucose through electrochemical reactions.
The CERA-PET Multi Test meter (M 400V) is intended for use in veterinary and medical professional setting to monitor blood glucose, lactate level in dogs and cats. It is also intended for use in the home setting to monitor blood glucose, lactate levels in dogs and cats. The CERA-PET Multi Test Meter is intended for in vitro diagnostic use.
The CERA-CHEK1Code Blood Glucose Monitoring System is intended to help people manage their diabetes with measuring their glucose level with fresh capillary whole blood the fingertip, the palm, the forearm, the upper arm, the thigh, or the calf for self-testing. It also provides professional healthcare personnel with the helpful information with measuring glucose concentration in fresh capillary whole blood. The CERA-CHEK 1Code Blood Glucose Monitoring System is intended for in vitro diagnostic use.
Products - Human Chorionic Gonadotropin (HCG) Test Midstream (Colloidal Gold Immunochromatographic Assay) Product Description - Sensitivity: 25 mIU/ml Accuracy: > 99.5% ISO13485 & CE approved INTENDED USE Easy-Sweet hCG Test Midstream is an in vitro diagnostic (IVD) qualitative test for rapid detection of hCG in urine. This test is designed for self-testing use only. PRINCIPLE Easy-Sweet. hCG Midstream is two-side sandwich immunoassay for the qualitative determination of human chorionic gonadotropin (hCG) in urine. The membrane was precoated with anti alpha hCG capture antibodies on the test band region and goat anti mouse on the control band region. During the test, the urine specimen is allowed to react with anti beta hCG monoclonal antibody-colloid gold conjugate, which was predried on the test Midstream. The mixture then moves forward on the membrane by the capillary action. For a positive specimen, the conjugate binds to the hCG forming an antibody-antigen complex. This complex is captured by anti alpha hCG antibody on the test region to produces a visual pink color band when hCG concentration in specimen is equal to or greater than 25 mIU/ml. Regardless of the presence of hCG, as the mixture continues to move across the membrane to the control band region, the complex is captured by immobilized goat anti mouse antibodies to form a distinct pink colored control band. The presence of the control band indicated: 1) a normal flow is obtained, 2) antibody pre-coated on control line and colloidal gold conjugate are functional. 1 pc/individual pouch , 500pcs/ctn or customized
General Information One-Step Chlamydia Rapid Test (Swab/Urine) is detection of Chlamydia trachomatis in female cervical swab, male urethral swab and male urine specimens to aid in the diagnosis of Chlamydia infection. Detection limit:1*103IFU/ml Specimen: Swab/Urine Reading Time : 10min
General Information The Urinalysis Reagent Strips (Urine) are firm plastic strips onto which several separate reagent areas are affixed. The test is for the detection of one or more of the following analytes in urine: Ascorbic acid, Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite , Leukocytes and so on.
General Information Method: Double Antigens Sandwich Method Sensitivity : 99.5% Specificity : 98.8% Specimen : Serum / Plasma Reading Time : 5- 10 min
The Herpes Simplex Virus Rapid Test is a rapid qualitative lateral flow test designed for the quantitive detection of IgG antibodies to Herpes Simplex Virus (HSV) in human serum/plasma samples. HSV-1 is usually associated with infection in oropharyngeal area and eyes, while HSV-2 causes mostly genital and neonatal infections (5, 6), however, the tissue specificity is not absolute (7). HSV-2 can be isolated occasionally from the oropharynx and 5-10% of primary genital infections may be caused by HSV-1. Infants infected with HSV appear normal at birth, but almost invariably develop symptoms during the newborn period (5, 8, 9). Neonatal HSV infection may remain localized or become disseminated. Localized infection may involve one or a combination of sites. These are skin, eyes, mouth or the central nervous system. Disseminated infection is manifested by pneumonitis, hepatitis, disseminated intravascular coagulopathy and encephalitis. Of the infants with neonatal HSV, about one half of those surviving will develop severe neurological or ocular sequelae. A number of serological procedures have been developed to detect antibodies to HSV. These include complement fixation, indirect immunofluorescent antibody, plaque neutralization, and ELISA (6, 8, 10). Antibody of the IgG class is produced during the first 2-3 weeks of infection with HSV and exists only transiently in most patients. Serologic procedures, which measure the presence of IgG antibodies, help discriminate between primary and recurrent infections, since IgG antibodies is rarely found in recurrent infections. High affinity IgG antibodies to HSV, if present in a sample, may interfere with the detection of IgG specific antibody (9). High affinity IgG antibody may preferentially bind to HSV-1 antigen leading to false negative IgG results. Also, rheumatoid factor, if present, along with antigen specific IgG, may bind to IgG causing false positive IgG results. Both problems can be eliminated by deactivating IgG in the sample before testing for IgG.
General Information One-Step Tetracycline Rapid Test is a competitive immunoassay for the semi-quantitative detection of the presence of Tetracycline residue in Milk,Honey,Tissue extract and Aquatic products. Detection limit: Milk 100 ppb ,Honey 20ppb , Tissue extract 100 ppb , Aquatic products 100ppb Specimen: Defatted milk, Honey, Tissue extract, Aquatic products Reading Time : 5-10min
General Information One-Step Beta-Lactam Rapid Test is a competitive immunoassay for the semi-quantitative detection of the presence of Beta-Lactam residue in milk. Specimen: Milk Reading Time : 5-10min
General Information One-Step Nitrofurans Rapid Test are competitive immunoassay for the semi-quantitative detection of the presence of AOZ,AMOZ, AHD, SEM residue in animal tissue. Detection limit:AOZ 1ppb , AMOZ 1ppb , AHD 1ppb , SEM 1ppb Specimen: Animal tissue Reading Time :10-15 min
One Step Troponin Test (Whole blood/Serum/Plasma FOR IN VITRO DIAGNOSTIC USE ONLY SPECIMEN COLLECTION 1. Testing should be performed immediately after the specimens have been collected. Do not leave the specimens at room temperature for prolonged periods. Specimens may be stored at 2-8C for up to 3 days. For long-term storage, specimens should be kept below -20C. 2. Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly. MATERIALS PROVIDED 1. Test cards individually foil pouched with a desiccant 2. Plastic dropper 3. Package insert MATERIALS REQUIRED BUT NOT PROVIDED 1. Timer/clock 2. Pipette 3. Controls ASSAY PROCEDURE 1. Read package insert carefully before testing. Allow the test devices, whole blood, serum or plasma to equilibrate to room temperature (15-30C) prior to testing. Do not open pouches until ready to perform the assay. 2. Remove the test device from the foil pouch and use it as soon as possible. 3. Place the test device on a clean and level surface. Hold the dropper provided vertically and transfer 3 drops of specimen (100�µl) to the specimen well (S) in the test device. 4. Wait for the red line(s) to appear. The result should be read between 10 to 15 minutes. INTERPRETATION OF RESULTS 1. Positive Two colored lines should be observed in the viewing window. The line in the test region (T) is the probe line; the line in the control region (C) is the control line, which is used to indicate proper performance of the device. The color intensity of the test line may be weaker or stronger than that of the control line. 2. Negative The control line appears in the test window, but the test line is not visible. 3. Invalid No line appears in the control region. Under no circumstances should a positive sample be identified until the control line forms in the viewing area. If the control line does not form, the test result is inconclusive and the assay should be repeated.
One Step Fecal Occult Blood (FOB) Rapid Test Cassette (Feces) Cat. No.: RH0301T INTENDED USE The One-Step Fecal Occult Blood (FOB) Diagnostic Kit is a qualitative detection of human occult blood in feces forself-testing. PRINCIPLE The One-Step Fecal Occult Blood (FOB) Diagnostic Kit is an immunochromatographic sandwich method, which employ two specific monoclonal antibodies to selectively identify hemoglobin in test samples. The result is very specific, and easier to interpret than those of guaiac-based test. The sensitivity is very high with the ability to detect 200ng/ml hemoglobin in feces. In addition, the accuracy of the test is not affected by interfering substances, and dietary restriction is not necessary. STORAGE The kits should be stored at temperature 4-30�°C, the sealed pouch for the duration of the shelf life (24 months). Do the test in 1 hour after open the pouch. WARNING AND PRECAUTIONS 1. For in vitro diagnostic use only. 2. Do not use kit beyond the expiration date. 3. Patient specimens may contain infectious agents and should be handled as though capable of transmitting disease. Wear disposable gloves throughout the specimen collection and assay procedures. 4. The test device should not be reused. REAGENTS AND MATERIALS PROVIDED 1. One pouched cassette with desiccant. 2. One operating Instruction MATERIALS REQUIRED BUT NOT PROVIDED 1. Clock or Timer SPECIMEN COLLECTION AND PREPARATION 1. Collect stool sample by using the sample collection device provided. 2. Unscrew the top of the sample collection device, take out the sample collection stick, and collect the sample by dipping the stick into 3 different places of the stool sample. 3. Put the sample collection stick back in the sample collection device and screw together tightly. 4. If the sample cannot be tested on the day of collection, store the stool sample at 4C. Bring the specimen to room temperature before testing. ASSAY PROCEDURE 1. Remove the test device from foil pouch by tearing along the notch. 2. Specimen collection. Please see also SAMPLE COLLECTION AND PREPARATION 3. Shake the sample collection device several times. 4. Holding the sample collection device upright, carefully unscrew the tip of collection device. 5. Squeeze 2-3 drops of the sample solution on the test sample pad. 6. Read the test results in 5 minutes. INTERPRETATION OF RESULTS Negative: Only one colored band appears on the control region (C). No colored band in the test region (T). Positive: In addition to the control band (C), a distinct colored band also appears in the test region (T). Invalid: If no bands appear, or a test band appears without a control band, the test should be repeated using a new test device.