Please click here to check who's online and chat with them.

Find Verified Diagnostic Kits Suppliers, Manufacturers and Wholesalers

Jun-01-09
Microwave is a kind of oriented electromagnetic radiation wave whose working efficiency is between 300 and 300000 mhz, with the wavelength being 100cm-1.0mm. It was used in the medical treatment in the 1940s and the commenly used frequencies are 433 mhz, 915 mhzíó2450 mhz of which 2450 mhz is used widely in each clinical department.
Jun-01-09
Main probe: 3.5MHz 80 array-element electronic convex array
Depth: 200mm
Resolution: transverse 2mmú¼vertical 1mm
Gray scale: 256 grade
Display mode: BíóB/BíóB/MíóM
Monitor Screen: 14" plane right-angle, 15" color display
pseudo-color image processing,eight-color combinations are suitable for gastrointestinal diagnosis
Film-playback function
Image processing: pre- processingíóframe correlationíóinterpolation
focusing mode: variable aperture, four-segment electronic focusing and sound through mirror focusing
Measuring function: distanceíóareaíócircumferenceíóheart rateíóslopeíóGSíócaput and arm lengthú¿CRLú¬íóBPDíóhead circumferenceú¿HCú¬íóACíófemoral lengthú¿FLú¬íófetal ageíófetal weight and EDD Calculation Software
Amplification ratio: 1ú¼1.2ú¼1.5ú¼í-2.0
Depth promotion: amplification promotion
Image turnover: polarity and left/right reversal
Posture marker:11 kinds of posture markers with the probe position
Information display: dateíórealtime timeíócase numberíóvarious prompting messageíófull-screen character edition etc
Volume: 500mm(width) í-1200 mm(high) í-700mm(depth)
Weight: about 46kg
Standard configuration:1 host,1 14" monitor screen,1 3.5MHz line array probe

Standard Lot
Jun-01-09
Main Specifications
Permitted gathering amount(entries) of sample:1-1000(or more)
The range of detecting speed(µm/s):0-180
The gathering amplitude number of images(hardwood):0-75
The diameter resolution of particles(µm):3-50
The time of acquisition and analysis(s):1-5 or longer
Group number of image acquisition(group):1-10
Features
During the system''''s design process,we fully consider the practical need of basic clinical institutions.it has the features of simple and reasonable of inspectors and is the epochimaking transform of inspecting means.structureíóstable performanceíófriendly interfaceíóintuitionistic and lively operation.Operator can gain the method of operation without special training.It thoroughly changs the shortcomings such as no quantization standard and randomness of man-made detection ,allows normal inspector to obtain the inspection techique which can just be done with abundant experience in the past,greatly reduces the knowledge pressure
High intelligentification degree,automatic detectioníóautomatic analysis and automatic calibrate function assure the accuracy of detecting data under any amplified multiplying factor,it can objectivelyíóaccurately and scientifically provide detecting data for the multi-analysis of sperm quality.
Overall íóintuitionistic data image detecting analysis,abundant detecting data,overall analytical data,detection of 34-item semen index,three speed distribution graph,quick detecting,transient completion of detecting analysis. It greatly relieves the work intensity of working man and effectively reduces pollution.strong maneuverability,the function of count display on the same screen,immediate display of detecting data,repeated verification of detecting results,directíóclearíóbeautiful printing report and statement design makes you clearly understand the diagnostic results
It has database function,testing results can be stored in the system harddisk, it also has the function of multi-inquiryíómodificationíóstatistics and testing report printing and provides advanced means for clinical scientific research and teaching.strong expanded function,it can be used in the analysis and detection of the features of bolld corpusculus and Escherichia by simple threshold setting.it can also be used in special profession such as animal and animal husbandry.
Jun-01-09
Blood coagulation analyzer

S21 type single channel blood coagulation analyzer
Performance Characteristics
International standard quantitative methodú¿CLAUSS methodú¬,with unique intelligent software,can decrease measuring interference and fluctuation and make the measurement more accurate
Optional PT forward algorithm(DERIVED method) is used to determine fibrinogen,which can save reagent
It is equipped with thermostat and thereí»s no need for other water bath cases
Little sample and reagent consumption assures tremendous potential to reduce costs
Short sample pre-warming time,quick testing speed
Full chinese menuíóconvenient operation
Two chassis colors is optional
Built-in printer,chinese report with normal referenca value is convenient for clinicians to refer
Specification
Measuring principle: first differential apogee method
Measuring wavelength: 70nm
Reagent amount: 20-40ª¦L
Sample amount: 20-30ª¦L
Result storage:6000 items
Calculation function: Síó%íóPTRíóINRíóg/L conversion
Calibrated curve:automatic storage, automatic calling
Temperature control precisionú¦37íµí+0.5íµ
Sample-adding gun: photoelectric trigger, automatic trigger measurement
Testing cup: truncation pyramidale cup
Stirring function: automatic magnetic stirring
Display: 19264 LCD
Interface: RS232 standard serial port
Main Analytical Items
Prothrombin time
Activated part thrombin time
Fibrinogen
Thrombin time
Crawler enzyme time
Internal shock coagulation factoró°íóó(íóóvíóón
External shock coagulation factoró=íóó)íóóníóó·
Protein S
Protein C
lupus anticoagulant analysis
Anti-Xa factor heparin detection
S22 type dual-channel blood coagulation analyzer
Two testing channels
The testing of two different items at the same time
Online sample-adding device
Full chinese display
S24 type four-channel blood coagulation analyzer
Four testing channels
The testing of four different items at the same time
Online sample-adding device
Full chinese display
May-27-09
Malaria test kit is used for the rapid initial detection and/or confirmation of malaria infection in the blood and test Plasmodium falciparum (Pf), vivax (Pv) antibody. We provide an easy and efficient way to check for malaria infection - a possible deadly health problem within 10-15 minutes with high sensitivity.

Specification: 3. 0mm, 4. 0mm, 5. 0mm or according to customers requirements.
Packing details: Cassette: 40pcs/box, 50boxes/carton.
1348 Diagnostic Kits Suppliers
Short on time? Let Diagnostic Kits sellers contact you.
May-27-09
HCG test kits is a rapid test to detect the presence of HCG in urine or serum specimens in a qualitative format sensitive to 20mIU/ml. The test utilizes a combination of monoclonal and polyclonal antibody reagents to selectively detect elevated level of HCG in urine or serum. The immunological specificity of the test virtually eliminates cross reactivity interferences from the structurally related glycoprotein hormones hFSH, hLh, hTSH at physiological levels.


Specification: 3. 0mm, 4. 0mm, 5. 0mm or according to customers requirements.
Packing details: Midstream: 20pcs/box, 30boxes/carton.
Cassette: 40pcs/box, 50boxes/carton.
Strip: 100pcs/bag, 100bags/carton
Container loading: Midstream: 250,000pcs/20FT container.
Cassette: 500,000pcs/20FT container.
Strip: 1,300,000pcs/20FT container.
May-16-09

Chlamydia

MOQ: Not Specified
Supplier From Shanghai, Pudong New District, China
Specimen: Swab/Urine .

Format: Cassette.
May-16-09

Strep A

MOQ: Not Specified
Supplier From Shanghai, Pudong New District, China
Specimen: Throat Swab.

Format: Cassette/Strip.
May-16-09

Mono

MOQ: Not Specified
Supplier From Shanghai, Pudong New District, China
Specimen: Whole Blood/Serum/Plasma.

Format: Cassette.
May-16-09

Hcg

MOQ: Not Specified
Supplier From Shanghai, Pudong New District, China
Specimen: Urine.

Format: Cassette/Strip/Mdistream.
May-16-09

Fob

MOQ: Not Specified
Supplier From Shanghai, Pudong New District, China
Specimen:Feces.

Format:Cassette/Strip.
May-06-09
Technical Specification:
Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite, leukocytes, glucose, specific gravity, and pH
Test wavelength: 525nm, 572nm, 610nm, 660nm
Test principle: Reflectance Photometer
Suitable strips: DIRUI H8 and H10 urinalysis strips
Test throughput: 120 strips/h or 60 strips/h optional
Data memory: 1000 patient results
Computer interface: RS-232 port
Display: 128Ãí¬32 dot-matrix LCD
Language: Chinese and English
Power supply: 100~240VAC, 50Hz/60Hz
Power: 25VA
Printer: Built-in thermal printer



Dimensions: 270mmÃí¬180mmÃí¬100mm
Weight: 1.15kg
May-06-09
Technical specification:

Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite,leukocytes, glucose, specific gravity, pH and VC
Test wavelength: 525nm, 572nm, 610nm, 660nm
Test principle: Reflectande Photometer
Suitable strips: DIRUI H8, H10 and H11 urinalysis strips
Test throughput:120 strips/h or 60 strips/h optional
Data memory: 1000 patient results
Computer interface: RS-232 port; parell printer port
Display: 240Ãí¬64 dot-matrix LCD
Language: Chinese and English
Power supply: 100~240VAC, 50Hz/60Hz
Power: 40VA



Dimensions: 376mmÃí¬316mmÃí¬170mm
Weight: 3.6kg
May-06-09
Technical Specification:
Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite, leukocytes, glucose, specific gravity, pH and VC
Test wavelength: 525nm, 572nm, 610nm, 660nm
Test principle: Reflectance Photometer
Suitable strips: DIRUI H8, H10 and H11 urinalysis strips
Test throughput: 514strips/h
Data memory: 2000 patient results
Computer interface: RS-232 port; parell printer port
Display: 240Ãí¬64 dot-matrix LCD
Language: Chinese and English
Power supply: 100~240VAC, 50Hz/60Hz
Power: 40VA
Printer: Built-in thermal printer

Dimensions: 380mmÃí¬378mmÃí¬275mm
Weight: 6.5kg
May-06-09
Specification:

Wavelength range:340nmíó405nmíó450nmíó492nmíó505nmíó546nmíó578nmíó630nm available
Wavelength Accuracy: Âí+2nm
Spectrum bandwidth: 6-12nm
Absorbancy:-0.3í½3.0 ABS
Resolution: Display with 1m ABS , internal with 0.1m ABS
Linearity: less than 0.5% within 1ABS
Stability: 20 minutes for warm-up and then í_3mABS/hour
Measure repeatability : 2m ABS
Measurement time: 0í½999s programmable
Delay time: 0í½999s programmable
Memory: 200 testing programs , 3000 testing results
Sampling: 100í½9999ª¦l programmable
Microflowcell volume :32ª¦l
Cross-contamination: í_1%
Differentiation rate: í_1%
Absorbancy repeatability: í_1%
Display: Matrix LCD
Power consumption: 85w



Dimension:462X418X232mm
Weight:6.5KG
May-06-09
Technical Specification
WBC HGB
LYM% LYM%
MON% MON%
GRA% GRA%
HCT RBC
MCH MCV
RDW-CV MCHC
RDW-SD PLT
PCT MPV
PDW P-LCR
RBC histogram
WBC histogram
PLT histogram
Calibration: manual calibration, automatic calibration,fresh blood calibration
Cross contamination rate: WBC,RBC,HGB<0.5%, PLT<1%
Testing diameter: 100um (WBC), 70um (RBC, PLT)
Aperture parameter: 3-Part Differential leukocytecount, 20parameters and 3 histograms.
Sample consumption: Whole blood 13uL, prediluted20uL
Counting mode: Whole blood and prediluted
Throughput: 60samples/hr
Display: 320+ù240 resolution, 5.6 inch LCD display
Reagent: DIRUI reagent
Power supply: 100~244VAC 50/60Hz
Power: 180W
Communication: RS-232C serial port
Environment requirement: ambient temperature 0-40, relative humidity 85%

Dimension: 448(L) +ù390 (W) +ù455(H)
Weight: 19kg
Feb-27-08
Hcg rapid diagnostics test kits(ce & iso)
Feb-27-08
HCV rapid diagnostics test kits(ce & iso)
Feb-27-08
Glucose rapid diagnostic test kits(ce & iso)
Mar-22-07
Rapid diagnostic test kits
1348 Diagnostic Kits Suppliers