Speicifcation: Type Lp7552 electronic digital weighing indicator A/d rate 10 times/second Capacity 15kg~10000kg Resolution 1/3000, 1/6000, 1/15000 Suitable for Floor scale, platform scale, bench scale, animal scale, weighing bar etc Dimension 270mm x 202mm x 141mm Power supply 6v4ah rechargeable battery or 110/220vac N.W. 1.8kg Interface Rs232, usb, ethernet for option Load cell 1~4 pcs (350ohm)
Nominal current(rms):50/100/200/300/400/600a Voutipn:+4.000v Measuring range:0~+900a Supply voltage dc:+15v Accurancyipn, +25degree Celsiusless than1.0% Mounting(mm):10.5*20.5 * open- loop supply voltage: dc +15.0v * capable measurement of currents: dc, ac, pulse with galvanic isolation between primary circuit and secondary circuit.
Nominal Current(RMS):50/100/200/300/400/600A Vout@Ipn:+_4.000V Measuring Range:0~+_900A Supply Voltage DC:+_12-15 Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):10.5*20.5
Nominal Current(RMS):10/25/50/75A Vout@Ipn:2.500+_0.625V Measuring Range:0~+_150A Supply Voltage DC:+5V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):8.2 in diameter
Nominal Current(RMS):30/300A Vout@Ipn:2.500+_2.000V Measuring Range:+_30/+_300A Supply VoltaIpn,+25
Pen type design, easy operation, the unique large-screen OLED color display High repeat-ability, with replaceable battery compartment Measure the hardness scale HB, HRC, HRB, HV, HS, HL and strength Ï?b Compatible with D or DL impact device Display Type:1.77 inch OLED with resolution 160x128 pixels Hardness Scale:HL, HB, HRB, HRC, HV, HS, Strength (Ï?b) Measuring Range:HLD (200-960) HRC(19.8-68.5) HB(30-651) HV(80-976) HS(26.4-99.5) HRB(13.5-100)Ï?b (375-2639) Impact Device:D type impact device (Standard) Accuracy:Measuring Error:+ - 6HLD (HLD=800), Repeatability:+ -6HLD (HLD=800) Measuring Direction:360 degree Material:Steel& Cast Steel, Stainless Steel, GC IRON, NC IRON, Cast Aluminum alloy, Copper-zinc alloy, Copper-tin alloy, Brass, Forged Steel, Alloy Tool Steel Resolution:1HL, 1HV, 1HB, 0.1HRB, 0.1HRC, 0.1HS Calibration:Automatic Language:English, Chinese, Spanish, Japanese Data Memory:100groups (each group includes 1 TO 7 testing values and 1 average value) Power:10440 Polymer li-ion battery, Capacity of 600 MA/H,voltage:3.7 V, warning under low voltage Shut-off:Auto off after 3 minutes of inactivity
Type includes:Silicon Piezoresistive Pressure Sensor,Capsule Pressure Transducer,Pt, Ps Transducer,Pt, Ps Transducer,Intelligent Transducer,Wireless pressure sensor Performance: Silicon Piezoresistive Pressure Sensor: Measurement Range: 0~36MPa; Tolerance:±3‰; Temperature Range:?55~?230? Different structure single or multi sensors can be applied to measure pressure of different gas or liquid; Output voltage signal or power current signal or digital signal;Size can reach F19mm Capsule Pressure Transducer Mainly used on the engines, measuring Pv, Ps, Pt, altitude etc. Pressure range: 0~36MPa, accuracy: ±1.5%; Temperature range: ?55~?220?; Major types: inductor, differential transformer, potentiometer etc. Pt, Ps Transducer Flow speed is held to be zero in the Pt cavity at the pitot front end. Therefore, the pressure measured is Pt. Ps can be measured by the side orifices. Pt-Ps=Pd. Altitude Transducer Measuring flight altitude, transforming the absolute pressure to a voltage output Intelligent Transducer? Sensing Pt & Ps, receiving resistance single of the temperature, and AOA voltage single from AOA Transducer. After error correction, it calculates the flight air data per the air data equation and supplies the results to other systems. Altitude & Velocity Transducer Used on aircrafts, measuring altitude, velocity and acceleration. Input is Pt, Ps, Pd and output is DC voltage, in proprtion with input signals. Ps is a dual-channel independent signal. Acceleration DC voltage signal in X, Y, Z axes and temperature signal are available. AWP Wireless pressure sensor Characters: 1.Low power consumption, long standby time 2.wide pressure measurement range10kPa~10MPa 3.Adjustable sampling rate(10min~12h) 4.Zigbee wireless communication protocol 5.long distance transmission 6.Full Metal Package with the IP65/67 Protection class 7.Good appearance
Type includes:TAT Transducer,Static Temperature Transducer,Platinum Resistance Temperature sensor,Thermocouple Transducer,AWT Wireless temperature sensor Performance TAT Transducer senses the air temperature of the stagnation point and output resistance signal Operation temperature range:-60 ? ~+350? Type:GZW-3, GZW-6, GZW-7 Static Temperature Transducer Measures the static T of air or liquid and provides resistance output accordingly. Measure range: -60?~300? Error less than ±1? Platinum Resistance Temperature sensor Measurement Range: -60?~300? Tolerance: d=±(0.5+5×10 -3 t)? Type: GWR-24, GWR-24A,GWR-31/31A,GWR-39, GWR-92, GWR-95 Thermocouple Transducer Use a thermocouple to sense the temperature of the environment or air flow, and produce a voltage signal (mv) Temperature range: 0ºC~900ºC AWT Wireless temperature sensor Model:AWT-GN-DU1 Characters: 1.Low power consumption, long standby time 2.High measurement accuracy 3.Adjustable sampling rate(10min~12h) 4.Zigbee wireless communication protocol 4.long distance transmission 5. Full Metal Package with the IP65/67 Protection class 6.Good appearance
Get the motion status( including linear acceleration, high/low frequency, etc.) through Measuring the acceleration, can be applied in different media(ultra-temperature, low temperature, intense radiation environment etc.) Weight:0.8-110g Measuring Range:500-10000g Temperature:-200 to 649ºC (Hz) Frequency Response: 1-10000 (Pc/g)Senbility:0.75-200
Vibration transducer works based on the piezo effect of the piezoelectric materials. Current product can stand 482°C, used on aircraft engine health analysis system. Meanwhile, our products are widely used in different industries. 1. Piezoelectric Vibration Sensor Operating Temperature: -200ºC~649ºC Measuring Range:500g Frequency Response:10Hz~2500Hz 2.Application: 1) Aircraft, Engine and other industries facility 2) Aircraft engine health analysis system 3) Vibration Monitoring(such as gas turbine and auxiliary power system,etc.) 4) Vibration Tester: Manually vibration monitoring instrument
P/N: M2734B hp TOCO Transducer 100% original Latex free one year warranty 1pcs/box
Pressure range: -1 20 bar(optional) Accuracy: 1%F.S. Supply voltage: 5VDC, 12VDC, 3.3VDC Output: 0.5-4.5V, Others on request Operating temperature: -40 105 Compensation temperature: -20 80 Operating Current: 3mA Temperature drift (zero & sensitivity): 0.03%FS Long-term stability: 0.2%FS/year Response Time: 4ms Overload pressure: 150%FS Burst pressure: 300%FS Cycle life: 500,000 times Pressure connection: NPT1/8 by default, Others on request Electrical connection: Packard connection Housing Material: Copper Shell Water-proof level: IP65 Explosion-proof level: Exia CT6 Weight: 0.08kg Medium: non-corrosive environment Sensor core: Al2O3-96% ceramic sensor Cable length: 0.3m for Packard, 0.5m for plastic direct cable by default
1.Features: Good constant inductors properties and anti-dc bias capability. With low-loss 2.Applications: . Output filter inductors, smoothing inductors, energy storage inductors . Energy-saving lamp electronic ballasts, and the differential-mode inductance in the EMC filter
Ratio 1000: 1 , 2000:1, 1000:5 (customized) Accuracy class 0.1%, 0.2%, 0.5% Primary current 0 - 500A AC and 0-1000A AC Signal output 1mV/A, 1mA/A Secondary voltage 0 - 0.5V AC and 0 - 1V AC; Secondary current 0-1A or 0-5A AC Max. Cont. Input current 1200A Load capacity 4 Over voltage category CAT III 600V Frequency range 10Hz-10MHz Dielectric strength 3KV 50Hz/60Hz at 1minute Temperature range -40C to +55C Output 2.5 meter cable with D01 or BNC connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation clamp type Output mode lead output(2.5m) Accuracy (1000A Range) 0-10A 0.5% 10-100 0.2% 10-1200A 0.1% Phase Shift(1000A Range) 0-10A 0.5 10-100 0.2 100-1200A 0.1 Mechanical parameters Dimensions (L x W x H) (mm) 105 x 218 x 30 Weight (g) 650 Holding wire diameter (mm) 52 Max. jaw opening (mm) 52 Jaw color Red & Grey Material PC+ABS, UL94 V0
FEATURES Suitable for 5A, 10A cable online measurement Holding wire diameter: 8mm Dimension: 42.6mm 122.5mm 23mm Load capacity: 4 Installation: clamp type Output mode: lead output PARAMETERS Electrical parameters Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.1% Primary current 0 - 10A AC Secondary current 0 - 10mA AC (customized) Max. Cont. Input current 12 A Load capacity 4 Over voltage category CAT III 600V Output signal (AC current) From 0 to 10mA AC at nominal input current Output signal (AC voltage) From 0 to 100mV AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 42.6x122.5x23 Weight (g) 250 Holding wire diameter (mm) 8 Max. jaw opening (mm) 8 Color Black Material PC+ABS+Polycarbonate, UL94 V0
Introduction AC grid transducer converts an ac voltage or current input into a load independent output signal. With excellent temperature characteristic and good working stability. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage.
Introduction DC grid transducer isolate the DC input signal from the DC output signal, which is directly proportional to the input signal. These isolators can be used to prevent earth loops, which occur when a measuring source. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. With excellent temperature characteristic and good working stability. Main features ·Input: DC grid customized input ·Output: 0-5V,0-10V,4-20mA, 0-20mA optional (One channel) ·0.2/0.5 measurement accuracy ·100ms response time(T type 1s/500ms) ·Minimum thickness of size (T type) ·35mm Din rail mounting ·Rs485 port optional
Introduction AC power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt) and reactive power (var). Two output signals combination in one transducer. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. Main features ·Input AC grid active power(W): 5A(100V) / 1A(100V) / 5A(400V) / 1A(400V) ·Output: 0-5V,0-10V,4-20mA, 0-20mA optional ·Power supply: 85~265VAC/380VAC ·Three phase independent measurement ·RMS measurement and output ·0.5 measurement accuracy ·35mm Din rail mounting ·RS485 port optional ·Support customized parameters
Introduction AC programmable transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Total four channel output, with panel key or PC control programmable, user can free to set 4 different data from max 26 electrical parameter for sampling and analog signal output. Have three channel digital inputs and optional RS485-Modbus communication functionality. Can monitor the galvanically isolated DI signal and programmed the transducer with customized SCADA software. Any of the measured parameters can be read out via the optional RS485-Modbus connection. Features ·Input three phase AC grid parameter: 5A(100V) / 1A(100V) / 5A(400V) / 1A(400V) ·Output: 4-20mA/0-20mA; 0-5V/0-10V optional ·85~265VAC/380VAC wide voltage AUX for most country and application ·With 4 channel output (support max 22 types parameter for analog output) ·Front panel with 4 keypad for analog parameter configuration, do not need back ground software. ·With RS 485 port for remote electrical data ·500ms response time ·0.5 measurement accuracy ·35mm Din rail mounting ·Advanced electrical parameter ready optional ·SOE function optional
Introduction BJ-QP series electrical transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Main features ·Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. ·Converts AC/DC electrical parameter input into a load independent output signal. ·Excellent temperature characteristic and good working stability. ·The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. ·The unit conforms to IEC 60688. In an addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage.