later wiil be given given later
Scratch Grinding Tester Automobile line inspection equipment Wire and Cable Detection Equipment It is applicable for assessing the scratch-resistant performance of automobile wire insulation with external forces in line with the requirements of GB/T12528-2008. Main parameters: 1. The scratch grinding device exercises in two directions along wire axes with a stroke above 10mm 2. Exercise frequency: 50~60 cycles/min 3. Minimum distance between test points and test point and test sample end: >10mm; rotation angle of test sample: 90° 4. Length of test sample: Test sample which is about 750mm is firmly fixed to a steel anvil 5. Weight: 400, 700, 1000g (weights applied to scratching needle) 6. Function: The device will stop when the scratching needle grinds through insulation and comes into contact with conductor
Resistance Test Instrument Supplier ZY9733 and ZY9734 digital desk type low current resistance measuring meters are suitable for units concerned to measure the DC resistance of various components and parts with certain limitations on current, such as platinum resistor, coppery thermal resistor, PTC ceramics, thermistor and various wire rods, etc. 1. Key features 1.1 It adopts a large green LED to display measured value, which is striking and clear. It also adopts the four-terminal resistance measurement method to eliminate the impact of conductor resistance, and the measurement accuracy is high. 1.2 There are a variety of specifications, and each specification has four scales to meet the measurement requirements of different users. 1.3 The test current is lower than similar equipment, which effectively prevents the impact of components and parts on resistance. 1.4 ZY9734 type has a RS-232 serial data output interface to facilitate the connection to computer. 1.5 It adopts a novel plastic shell and can changes the inclined angle between the device and table by adjusting the handle position, so as to determine the suitable panel observation angle. It has a well-designed appearance and is easy to use. 2. Main technical indicators Temperature: Reference conditions: 20±5; nominal condition: 5~35 Relative humidity: Reference conditions: 40~60%; nominal condition: 25%~75% Power source: AC 220V±10%, 50Hz, power consumption: About 5VA.
Sawdust Moisture Meter MS-W Sawdust moisture meter with seperate probe MS-W used for measuring moisture content of wood materials(such as sawdust,paillasse,bamboo powder and wood chips).It applicable of paper making , flakeboard , furniture and mechanism of charcoal industry. Features: * It is portable, compact, easy to use and the moisture measurement readings are instant. * Digital display with back light gives exact and clearly reading although you stay at the somber conditions. * The moisture meter operation has automatic temperature compensation. * Data hold function. * Low battery alert. Specifications: Digits LCD with backlight Measuring range :0-84% Operating conditions: Temperature:0-60 Humidity:
Power Distribution Components Air Circuit Breaker Moulded Case Circuit Breaker Switch Dis connectors Changeover Switches By Pass Switches HRC Fuse Links & Fuse Bases Power Control Components Power Contactor Electonic & Thermal Overload Relays Motor Protection Circuit Breaker Controling & Signalling Devices Industrial Plugs & Sockets Motor Starters Limit Switches Foot Switches Solid State Relays Brakes Final Distribution Components Miniature Circuit Breaker Residual Current Circuit breaker Distribution Boards
KYN28A-12 (GZS1-12) Model Indoor AC Metal Clad Intermediate Switchgear,KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear,Circuit Breaker Switchgear,High and Low Voltage Switchgears,Indoor AC Switchgear Product Description KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear, this product is suitable for three phase AC power system with rated voltage 12KV and rated frequency 50Hz, is used for receiving and distributing the power energy, to control, protect and monitor the circuit. Product Features Meet the standard: GB3906-97 3-35KV AC Metal-enclosed Switchgear, GB11022-89 High-voltage Switchgear General Technical Conditions, IEC298 (1990) AC Metal-enclosed Switchgear and Control Equipment With Rated Voltage Above 1kv and or Below 50kv , DL404-97 Order Technical Conditions for Indoor AC High Voltage Switchgear Cabinet. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears GGD series low voltage switchgear is used for power lighting Product Description GGD series low voltage switchgear is used for power lighting, power transformation, distribution and control for AC distribution system with rated frequency 50HZ and rated operation voltage 380V, rated current up to 3150A at power plant, substation, mine enterprises and other users. It owns high breaking capability, rated short time withstand current can be up to 50KA, circuit layout is flexible and combination is convenient and so on. It is one of typical products for assembled type, fixed panel switchgear in domestic. This product complies with the national standards GB7251 Low-voltage Switchgear and Control Equipment, international standard IEC 60439 Low - voltage Switchgear and Control Equipment. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
XGN2 Type Modular High Voltage Switchgear,High Voltage Switchgear,High and Low Voltage Switchgears XGN2 type modular high-voltage switchgear cabinet is applied to receive and distribute the electrical energy in three-phase AC power system with rated voltage 3, 6, 10KV and rated frequency 50HZ Product Description XGN2 type modular high-voltage switchgear cabinet is applied to receive and distribute the electrical energy in three-phase AC power system with rated voltage 3, 6, 10KV and rated frequency 50HZ, especially for the frequently operated occasion. Its busbar system is a single busbar (which can derive the single busbar with bypass and double busbar structure). The switchgear cabinet is in line with the requirements of the National Standards GB3906 3-35KV AC Metal-enclosed Switchgear and the international Standard IEC298, also there are proposed "five anti" interlocking functions such as anti-breaking and closing by mistaken for circuit breaker, anti-breaking and closing disconnector switch with load, anti-breaking and closing grounding wire/switch with load, anti closing circuit breaker/disconnector switch with grounding wire/switch, anti entering charged interval by mistaken. Product Features The main switch of the switchgear applies ZN28A-10 series vacuum circuit breakers, equipped with CD117 series of electromagnetic operating mechanism and CT19 series of spring operating mechanism. Using GN-30 rotary isolating switch. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Gck low-voltage draw out switchgear, low voltage switchgear, draw out switchgear, circuit breaker switchgear High and low voltage switchgears Gck series low voltage draw out switchgear is applicable for three phase four wire/five wire ac power system with rated operation voltage 380v Product description Gck series low voltage draw out switchgear is applicable for three phase four wire/five wire ac power system with rated operation voltage 380v, used for electric power receiving and feeding, reactive power compensation, electric energy calculation, lighting and motor centralized control at power plant, substation, mine enterprises, high buildings. This product complies with the standards gb7251 low-voltage switchgear and control equipment, jb / t9661 low-voltage draw out type switchgear, iec 60439-1 low - voltage switchgear and control equipment. We are pleased to deliver transformer, distribution transformer, power transformer, oil transformer, dry type transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
JH Digital Tension Meters Large, easy to read backlit, graphic display with adjustable backlighting and contrast. Display shows tension, name of calibration selected, running line minimum and maximum tension values, and battery charge level. Indicate length of material in feet or meters.
JH Digital Tension Meters Large, easy to read backlit, graphic display with adjustable backlighting and contrast. Display shows tension, name of calibration selected, running line minimum and maximum tension values, and battery charge level. Indicate length of material in feet or meters.
JH Digital Tension Meters Large, easy to read backlit, graphic display with adjustable backlighting and contrast. Display shows tension, name of calibration selected, running line minimum and maximum tension values, and battery charge level. Indicate length of material in feet or meters.
JH Digital Tension Meters Large, easy to read backlit, graphic display with adjustable backlighting and contrast. Display shows tension, name of calibration selected, running line minimum and maximum tension values, and battery charge level. Indicate length of material in feet or meters. Packaing:59*78*183mm
SCR Voltage Regulator
•Large and easy-to-read LCD •Data Hold Function •Waterproof and designed to float •Automatic Temperature Compensation •Replaceable probe
•Waterproof and designed to float •Easy-to-read Custom Dual-level LCD •On-the-spot measurement •Automatic Temperature Compensation •With Temperature Display •Replaceable pH electrode Available for wide applications, such as aquarium, beverage, fish hatcheries, food processing, photography, laboratory, quality control, school & colleges, swimming pools, water conditions.
Folding design feature to use expediently Replaceable pH electrode Clear LCD display featuring both pH, temperature and humidity The KL-0101 offers increased accuracy when measuring solutions at different temperatures as it automatically measures the temperature and compensates the pH reading accordingly.
This compact tester features a large easy-to-read LCD. Unlike other pH testers, the pH electrode can be interchanged with any pH electrode of different size and shape. This allows you to use application specific electrodes and saves the cost of a new meter when it is finally necessary to replace an exhausted electrode. The tester is fast, accurate, lightweight. Testing pH has never been easier!
According to: Technique Regulation of Concrete Defect Detection with Ultrasonic CECS21: 2000 Depth measurement principle When vibration energy transmits through the concrete and passes the crack, the vibrate energy will be diffracted at the point of the crack, whose diffraction angle has geometrical relationship with the crack depth. DJCS-05 crack depth measurement instrument adopts this geometrical between the diffraction angle and depth to realize high precision depth measurement. Feature and Specification Easily operation: Start measure when turn on, simply press to finish testing. Result Intuition: No wave speed test and calculate to display the crack depth directly Data processing: Data can transfer to PC, and then generate test report rapidly. Depth scale: 10-350mm Test precision: 5% Data storage: 10600 depth data Display: 4” Resolution 160*128 Power supply: 9VDC (6 AA battery) Work environment: Temperature -5~40centigrade; Humidity 85% Size: 220*180*80mm Weight: 1000g
Purpose SYQ61 concrete strength tester is used to test compressive strength of concrete by two ways: rebound and ultrasonic-rebound method. Also, it can be used to test sound time and speed in concrete. Specification Technical specification for inspection of concrete compressive strength by rebound method (JGJ/T23-2011) Technical specification for detecting strength of concrete by ultrasonic-rebound combine method (CECS02:2005) Performance 1. Multi-function for testing compressive strength of concrete. It is used to test the compressive strength of concrete by rebound method and ultrasonic-rebound method. 2. Get the compressive strength value of concrete by ultrasonic-rebound method in one instrument. It need two instruments usually, one to test sound speed in concrete, the other to test rebound value. 3. Can save test date. This is convenient for laborer data management. 4. Real USB transmission. Data can be transmitted to computer for future process and analysis. 5. Powerful data process and analysis software in windows. Test data can be export to word or excel for future process and analysis. Technical Data 1. Permissible sound time error: +/- 0.1µs 2. Sensor frequency: 50KHz 3. Rebound kinetic energy: 2.207J 4. Rebound springs Rigidity: 785.0+/-40.0(N/m) 5. Rebound bar impact length: 75.0+/- 0.3 mm 6. Rebound value permission error: =< +/-1 7. Average rebound value on Calibration anvil: 80+/-2 8. Temperature: -4°C ~ +40°C; 9. LCD screen: 160*128(10×8cm) 10. Power: 6 dry cells, work more than 10 times 11. Size: 205mm*173mm*86mm 12. Weight: 850g