Parameters WEW-100 Accuracy 1% of indicated value Measuring range of force(kN) 2-100kN Subsection of force 1,2,5,10 Accuracy of deformation measurement 0.5%F.S Clamping diameter for round specimen(mm) ;6-22 Clamping width of flat specimen(mm) 40 Clamping thickness of flat specimen(mm) 0-15 Testing space Tension 550 Compression 500 Platen size 100 Distance of bending by pass roll(mm) 30-400 Piston stroke(mm) 250 Power supply : 50Hz Working environment Room temperature : relative humidity Overall dimension(mm) Frame machine730x500x2000 Control System 1070x810x1730 Weight(Kg) 1370
Digital control hydraulic compression testing machine 1. Maximum Testing Load: 600kN 2. Measuring Range of Load: (24-600) kN 3. Accuracy of Testing Load: 1% 7. Distance between Upper and Lower Platen: 225mm (Adjustable) 8. Size of Upper Compression Platen: 180mm 9. Size of Lower Compression Platen: 250mm 10. Piston Ram Stroke: 150mm 11. Power Supply: three phase, 380/220V;50/60Hz 12. Working Environment: 80% Overall dimension: Frame: 1120, 1650(MM) Weight: Frame:950kg
1. Maximum Testing Load: 2000kN 2. Measuring Range of Load: (80-2000) kN 3. Accuracy of Testing Load: 1% 4. Rate of Loading Speed: 0.5N/s~10kN/s 5. Accuracy of Rate of Loading Speed: 5% 6. Accuracy of constant testing Loading: 1% 7. Distance between Upper and Lower Platen: 500mm (Adjustable) 8. Size of Upper Compression Platen: 230;280mm 9. Size of Lower Compression Platen: 230;280mm 10. Piston Ram Stroke: 200mm 11. Power Supply: three phase, 380/220V;50/60Hz 12.Working Environment: 80% Overall dimension: Frame: 1115 Control System : 187; Weight: Frame:4850kg, 200kg
his series testing machine is suitable for tensile, compression, bending, shearing, peeling and tearing test of metal and nonmetal materials, such as rubber, plastic, electrical wire and cable, composite, profiled bar, bar metal, board, spring, components and so on. It confirms to ISO 75001ú¼ASTM A370, ASTM E4 ASTM E8 and JIS, DIN, BSEN testing standards. AD800 in this machine is whole digit multi center closed loop measuring and control system. It adequately absorbs advanced functional characteristics and integrates the latest international professionally developed measuring and control system. Control software can automatically finger out routine data, such as tensile strength, yield strength, modulus of elasticity, extend rate after rupture, non-proportional extend strength RP0.2, etc. It can adopt many kinds of controlling modes, such as constant force, constant displacement, constant deformation, and real time display many testing curves of force-displacement, force-time, stress-strain. These curves automatically switch. Testing process control and data processing conform to the requirements of International standards. This machine is beautiful, multifunctional, safe and easy. Parameters: WDW-1 WDW-2 WDW-5 Maximum force: 1KN 2KN 5KN Accuracy: í_í+1% (0.5% as special order) Measuring range of force (KN): 0.2%--100%FS Resolution of force: 1/200000 of maximum force and no subsection of all scale Accuracy of displacement measuring: í+0.5% Resolution of displacement: 0.03ª¦m Speed adjusting range of displacement: 0.001-500mm/min Accuracy of deformation measuring: í+0.5% Range of deformation measuring: 2%í½100%FS Speed adjusting range of force; 0.005-5%F.S / S Speed controlling accuracy of force: ¿Qí+2.0% of the set value (speedú+0.05%FS/S) ¿Qí+0.5%/í+1.0% of the set value ( speed¿R0.05%FS/S) Speed adjusting range of deformation: 0.005-5%FS/S Speed controlling accuracy of deformation:¿Qí+2.0% of the set value (speedú+0.05%FS/S) ¿Q í+0.5% of the set value ( speed¿R0.05%FS/S) Valid tension testing space: 800 Compression testing space: 700 Clamping sample: Flat and round sample Power supply: 380V/220ú¼50/60Hz Working environment: Room temperature 10íµí½30íµ, relative humidityí_80% Base configuration : Panasonic servo motor, precision photoelectric encoder Weight(Kg): 300
Test load: 0.098N (10gf), 0.246N (25gf), 0.49N (50gf), 0.98N (100gf), 1.96N (200gf), 2.94N (300gf), 4.90N (500gf), 9.80N (1000gf) Leus/indenter switch: With hand Turret Carriage control: Automatic loading and unloading method Magnification of microscope: For measurement: 400X (Object lens 40x , eyepiece 10x) For observation:200X (object lens 20x, eyepiece 10x) Load holding time: 5-60 second Measuring microscope: Min measuring unit: 0.0625um Testing field: 1-2967HV Micro test table: Dimensions 100x100mm Movement: 25mm in X&Y axis Max. height of specimen: 70mm ; Max. depth of specimen: 95mm Output: Installed with innner-printer and RS232 interface ; Power Supply: AC110V/220V 60/50HZ Dimensions: (L ) 425 X (W) 245X (H)490mm; Gross Weight:: 42KG, Net Weight: 35KG
2m transmission analyzer Basic functions 2m measurement Hdb3 and ami line codes Out-of-service 2mb/s, n*64kb/s ber testing In-service framed and unframed double-channel testing Pcm simulator''mode testing Frame data control and monitoring Timeslot activity monitoring, fas, n-fas, ts16mfo analysis Built-in 64kb/s tone channel listen capability Cas and ccs signaling generation and monitoring Round trip delay measurement Aps delay measurement Extensive error and alarm generation Vf tone generation and measurement Level measurement Pulse mask measurement Jitter measurements to itu-t standard o. 172 Frequency and offset measurement Clock slip measurement Up to +/-999ppm transmit clock deviation Clock source: internal, interface or external 2m clock/signal Real-time transmit circuit open/short indication
Product Description TLD1500 Series is high quality of Optical Fiber Checker. It contains the most advanced laser technology and microelectronics technology, and can be measured with various fiber optic adapter with 2.5mm common Interface. It is very convenient for them to check the single-mode and multimode fiber. Features High visible red laser output Easy-to-use "quick access" interface Small size, light weight, high reliability Battery for power supply Suitable for all 2.5 mm optical fiber connector Applications Fiber production and research devices Fiber network testing and maintenance Optical communication teaching and test
Product Features; Six Impact Devices are available for special applications(D,DC,D+15,C,DL,G) Direct display of hardness scales HRB,HRC,HV,HB,HS,HL; Software to connect with PC and Dataview for PC operation; Automatic identification Impact Devices and test direction (Except G); Software data and upperlower limits setting and sound alarm; Time and date setting; auto-clock; On-Board memory holds 240-1000 groups of data; Integral thermal printer, print all test results and histogram; For all metallic materials; Li Battery , low voltage indication and sound alarm; LCD with blue back-light, showing all functions and parameters; Wide measuring range; Long standby time and stable performance of field work; Technical specifications: Hardness Scale:HL,HRC,HRB,HV,HB,HS Accuracy:í+4HLD(760í+20HLD) repeatability of displayed value Standard Impact Device:D limits set measuring range:(170~960)HLDD Optional Impact Devices:C DC D+15 DL G Operating Temperaturee:0~40 Statistics Function:Average Max Min calculation,limits setting and alarm Testing direction:Automatic Min.thickness of hardened:0.8mm Chargeing time:3~5hours Power:Li Battery 4.2V/1600mAh Charger:5V/500mA Overall Dimensions:147*69*23mm Weight:186g Computer Interface:RS232 Min.Workpiece thickness:5mm (D DC DL D+15)1mm (C)10mm (G) memory:240~1000 groups Min.Workipece Weight:2~5Kg on stable support 0.05~2Kg with compact coupling Min.Radius of Workpiece:Rmin=50mm(with support ring Rmin=10mm) Max.Workpiece Hardnesss:996HV (D DC D+15 DL C) 646HB (G) Continuous Working Time:About 200hours
Six impact devices are available for special applications(d, dc, d+15, c, dl, g) Direct display of hardness scales hrb, hrc, hv, hb, hs, hl; Software to connect with pc and dataview for pc operation; Automatic identification impact devices and test direction (except g); Software data and upperlower limits setting and sound alarm; Time and date setting; auto-clock; On-board memory holds 240-1000 groups of data; Integral thermal printer, print all test results and histogram; For all metallic materials; Li battery , low voltage indication and sound alarm; Lcd with blue back-light, showing all functions and parameters; Wide measuring range; Long standby time and stable performance of field work;
Introduction Dj-500p demagnetizer has the biggest demagnetizing surface at the flat demagnetizer. It is the leading level at the demagnetizer surface, power consumption and work efficiency in china. It can produce a damping magnetic field.And it need not move the workpiece during demagnetizing.Based on fully taking into account demagnetisers reliability andstability , the design and special selection of materials make dj-500p type demagnetizer to be widely used. Dj-500p demagnetizer do not pollute the powerline.Large parts, large devices (such as calipers, needles, screws, nuts, change knives, scissors, blade) can be demagnetized easily. Major technical character 1. Application: magnetic metal parts and molds. 2. Demagnetized voltage (v): ~~ 380v 3. Demagnetized time (s): 2-5 s 4. Demagnetized area (mm): 500 ~{!a~} 500 5. Residual flux:
1.1 General introduction APGK-307 is special instrument for power system GIS mechanical properties measuring. The instrument takes IPC for the core to sample and data process. It has 12.1 LCD to display and 12.1 touch pad for operation. Rich experience database makes the tester more intelligence. The tester has the characteristic of accurate test data, strong anti-jamming, easy operation, small size and light weight. 1.2 Functions 1. Measure opening and closing time, synchronism performance ,bounce time and bounce times of common and graphite GIS. 2. Measure distance, average speed and instantaneous speed of on and off of common and graphite GIS. 3 Finish test of continuous on and off of common and graphite GIS. 4. Measure coil current of common and graphite GIS. 5. Draw GIS state-time curve, current-time curve, distance-time curve and speed-distance curve. 6. Show 12 GIS port status of common and graphite GIS. 1.3 Technique index 1) Time measuring: Number of ports of GIS measured :í_12 Range of the setting time during the measuring course: >100 seconds Resolution: 0.01ms 2) Distance measuring: Distance sample rules:0-3 Range:
1.1Product Introduction Apva-401 is a special instrument for testing characteristic of ct; the tester can finish ct transformation ratio test, ct polarity test, volt-ampere feature curve drawing and ct error drawing. It has large output, high precision, stable performance and automatic testing. 1.2 Funtion 1 ct transformation ratio test 2 ct polarity test 3 ct volt-ampere feature curve measurement 4 ct ratio error measurement 5 error curve measurement 6 result print 7 unload data to pc 8 pc online test .
1.1 Introduction APVA-402 is a special instrument for testing characteristic of CT and PT .The tester can finish CT/PT transformation ratio test, CT/PT polarity test, volt-ampere feature curve drawing and CT error drawing. It has large output, high precision,stable performance and automatic testing. 1.2 Funtion 1 CT/PT transformation ratio test 2 CT /PT polarity test 3 CT /PT volt-ampere feature curve measurement 4 CT ratio error measurement 5 Error curve measurement 6 Result print 7 Unload data to PC 8 PC online test . Wooden case.
1.1 General introduction APVA-403 CT analyzer is special tester for current transformer. It takes IPC as core to sample and data process. The instrument finishes CT tests based on different low frequency. It has 8.4 inches LCD to display and a 8.4 inches touch pad for operation. The tester has the characteristic of high precision, strong anti-jamming and easy operation. 1.2 Functions 1. Excitation curve, volt-ampere curve and error curve drawing 2. Second burden measurement 3. CT coil DC resistance measurement 4. CT transformation ratio test 5. CT phase polarity test 6. Automatically make WORD and EXCEL test report. 1.3 Technique index 1. transformation ratio test error
1.1 General introduction APLB-601 is an instantaneous signal recorder used for kinds of industry. It takes IPC as the core to sample and data process. It has 12.1 LCD to show, touch pad for operation, strong anti-jamming and easy operation. 1.2 Functions 1. Sample isolation between channels completely. 2. The instrument software has waveform zoom, data statistics, spectrum transformer and wavelet transformer tools. 3. Lots of test template to make customers finish test rapidly. 4. All the data can be exported through U-disk or wireless network. 5. Automatic upgrade interface of the tester make it easy to get latest software package and test template. 6. 12.1 LCD to show, touch pad for operation. 7. Automatically makes WORD and EXCEL test reports. 1.3 Technique parameters 1. Analog signal sample channels:12 2. Optional stalls: -450V~450Vú¼-100V~100Vú¼~10V~10Vú¼-20mA~20mA 3. Sample error: -450V~450V error
Sensitivity 0.1 ppm Accuracy 2 % Response T90 = 1 sec
Accuracy or tolerance ¦ when valve 20ppm1ppm While > 20ppm 10% Oil sample ¦50ml2ml gas sample ¦ 5ml0.2ml
PE-AOBDV Automatic Oil Breakdown Voltage Testeris a highly precise instrument, which can be applied to measure either the breakdown voltage or also check the withstanding voltage for a predefined time. Usual available automatic test sets only perform the former function, but PE-AOBDV can do both. PE-AOBDV can measure the breakdown voltage repetitively and computes an average reading, for a proper decision making. PE-AOBDV consists of an integrated Oil Cup, HV AC power source. Features - 0-80kV or 0-100kV smooth operation, 5mA trip current - Complete Automatic operation - Non-contact magnetic stirring - Programmable Stir, Hold, and Intermediate Stand times - Programmable voltage ramp rate - Repetitive test sequence and average readings - Digital display output - Integrated thermal Printer - Internal memory for data storage and recall - Included IS 6792, IEC 60156 and GB507-86 test sequences - Programmable test sequences as per requirement. 1 pc - 25 kgs.
Clamp on ground resistance tester ETCR 2000C *Accurate ground resistance measurement from 0.01to 1000Ohms *current measurement including leakage current *Accurate readings regardless of power quality in 1 seconds *Simple and easy to use, no test leads or auxiliary electrodes necessary *Data logging capability - 50 records *Individual data point recording *User selectable audible alarms *Auto power off *Low battery indicator *Large LCD display Ground Resistance: 0.010 - 0.099 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.001 Ohms) Ground Resistance: 0.10 - 0.99 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.01 Ohms) Ground Resistance: 1.0~49.9 Ohms (¿¬+ 1.5% ¿¬+ 0.1 Ohms, resolution 0.1 Ohms) Ground Resistance: 50.0~99.5 Ohms (¿¬+ 2% ¿¬+ 0.5 Ohms, resolution 0.5 Ohms) Ground Resistance: 100~199 Ohms (¿¬+ 3% ¿¬+ 1 Ohms, resolution 1 Ohms) Ground Resistance: 200~395 Ohms (¿¬+ 6% ¿¬+ 5 Ohms, resolution 5 Ohms) Ground Resistance: 400~590 Ohms (¿¬+ 10% ¿¬+ 10 Ohms, resolution 10 Ohms) Ground Resistance: 600~1000 Ohms (¿¬+ 20% ¿¬+ 20 Ohms, resolution 20 Ohms) Ground Leakage Current: 0.00~299 mA (¿¬+ 5% ¿¬+2 mA) resolution 1 MA Ground Leakage Current: 100~299 mA (¿¬+ 5% ¿¬+5 mA) resolution 1 mA Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA Ground Leakage Current: 10.00~20.00 A (¿¬+ 5% ¿¬+0.5 mA) resolution 10 mA.
Earth Resistance Tester: Model: ETCR2100+(basal) Category: Ground Resistance tester Earth Resistance Tester (ETCR2100+)-Illustration: ETCR 2100+ of Pincers Earth Tester, in the measurement of a grounding system with loop current, does not require breaking down the grounding wire, and need no auxiliary electrode. It is safe, fast and simple in use. 1.Wider range: 0.01Ñ+-1200Ñ+ 2.Stored data: 99 groups. 3.Resistance Resolution: 0.01Ñ+ 4.Size of Jaw: ¬¬32ú¿mmú¬ 5. Sound and light alarm, "beep - beep - beep -" alarm sound. 6. Breakthrough in self-test the boot a long time to wait, start immediately into the test. 7. Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, a fully intelligent. 8. Break the old product to heavy issues, more in line with characteristics of handheld devices. 9. The new design, panel 6 button operation, the performance through. 10. Lower power consumption: Maximum operating current not exceeding 50mA. 260*90*66(MM)