Model number: ecg-923 (three channel) Dimension:310mmx235mmx66mm Packing:375mmx295mmx195mm Weight:4.5kg(gross); 3.57kg(net) Three channel with interpretive Build in rechargeable li battery Chinese/english language Simultaneous 12 leads 320x240 graphic lcd, 5.7 inch screen Paper size: 80mmx20/30m Built in rs232 interface (usb is optional) 128 patients save/copy/communication
Model number: ECG-923A (Six channel) Dimension:310mmX235mmX66mm Packing:375mmX295mmX195mm Weight:4.5kg(gross); 3.57kg(net) Six channel with interpretive Build in rechargeable Li battery Chinese/English language Simultaneous 12 leads 320X240 graphic LCD, 5.7 inch screen Paper size: 112mmX20/30m Built in RS232 interface (USB is optional) 128 patients save/copy/communication
Dwd-2401 home ecg 1. Ordinary people can understand ecg by "home ecg". Home ecg is a new type of heart health care instrument. It display digitally five type of the most important ecg parameters. So ordinary people without professional background can understand easily. 2. You can check your heart anytime and anywhere you wanted. "home ecg" is suitable for people to monitor heart outside hospital, at home, office etc. It has the following features: small size, convenient use, not confined to places and time, long monitoring time, alarm when the parameter beyond the preset threshold. It is the ideal health care instrument for patients of coronary heart disease, arrhythmia and high blood pressure. For sub health people, it is a good method to evaluate heart status. 3. Provide for you a heart insurance. Using "home ecg", you can monitor heart in real time. It helps prevent heart disease from happening and is also a good guidance for exercise. User may know his heart status by observing the data displayed on the lcd, especially on some special time such as eating, sleeping, toilet, running etc. It is also a reference to evaluate the medicine effect. Five types of ecg parameter are displayed: Heart rate: Normal: 60~100 beats per minute, Tachycardia: more than 100 beats per minute; Bradycardia: less than 60 beats per minute. St segment: "elevation" and "depression" indicate heart ischmia. Normal range is " 0. 1~ 0. 2". Qrs amplitude: High blood pressure patient with "high" qrs amplitude indicate myocardial hypertrophy. Arrhythmia: Check "ventricular premature beat" and "atrial premature beat" and alarm each time when such event happened. Pacemaker signal: For patient with pacemaker, it can check the pacemaker signal and make a judgment if the pacemaker work well.
ECG ECG-01: Digital 12-lead, Single channel, character LCD, measure report, RS232 interface (software optional) ECG-01D: Digital 12-lead, Single channel, 320x240 LCD, waveform display, RS232 interface (software optional),measure report, 8 patients' information deposit ECG-03: Digital 12-lead, Single/Three channel, 192x64 LCD, waveform display,RS232 interface (software optional), measure report ECG-03A: Digital 12-lead, Single/Three channel, 320x240 LCD, waveform display, RS232 interface (software optional), 8 sets data memory, measure and analysis report (analysis software is optional) ECG-03B: Digital 12-lead, Single/Three channel, 192x64 LCD, waveform display, RS232 interface, software is optional, measure and analysis report (analysis software is optional) ECG-061: Digital 12-lead, Six channel with analysis and waveform display, RS232 interface (software is optional), 16 sets data and analysis result memory (optional) ECG-121: Digital 12-lead, Twelve channel with analysis and waveform display, RS232 interface (software is optional), 16 sets data and analysis result memory (optional)
Ecg/ekg Ecg-01: digital 12-lead, single channel, character lcd, measure report, rs232 interface (software optional) Ecg-01d: digital 12-lead, single channel, 320x240 lcd, waveform display, rs232 interface (software optional), measure report, 8 patients' information deposit Ecg-03: digital 12-lead, single/three channel, 192x64 lcd, waveform display, rs232 interface (software optional), measure report Ecg-03a: digital 12-lead, single/three channel, 320x240 lcd, waveform display, rs232 interface (software optional), 8 sets data memory, measure and analysis report (analysis software is optional) Ecg-03b: digital 12-lead, single/three channel, 192x64 lcd, waveform display, rs232 interface, software is optional, measure and analysis report (analysis software is optional) Ecg-061: digital 12-lead, six channel with analysis and waveform display, rs232 interface (software is optional), 16 sets data and analysis result memory (optional) Ecg-121: digital 12-lead, twelve channel with analysis and waveform display, rs232 interface (software is optional), 16 sets data and analysis result memory (optional)
Ecg1501 Digital isolation technology minimizes the time and temperature drift of the components; Selectable rhythm lead makes it easy to observe arrhythmia ecg waveform; Visual alarm for ecg lead-off; Automatic measurement of ecg waveform assists the doctors with diagnosis; High resolution built-in thermal recorder prints out ecg waveforms , annotations and parameters for diagnosis reference. Fully charged battery supports continuous examination and print-out for 60 minutes or more , with normal operation for 2 hours. True one touch operation. 370mmx330mmx230mm , 2kg/5.3kg
Ecg1501 Digital isolation technology minimizes the time and temperature drift of the components; Selectable rhythm lead makes it easy to observe arrhythmia ecg waveform; Visual alarm for ecg lead-off; Automatic measurement of ecg waveform assists the doctors with diagnosis; High resolution built-in thermal recorder prints out ecg waveforms , annotations and parameters for diagnosis reference. Fully charged battery supports continuous examination and print-out for 60 minutes or more , with normal operation for 2 hours. True one touch operation. 370mmx330mmx230mm , 2kg/5.3kg
Multi-channel interpretive electrocardiograph Ecg-32a: three channel intepretive ecg machine High resolution thermal array printer; 1/2/3/3+2 channel printout format 192x64 lcd to display setting menu Simultaneous acquisition of 12 lead ecg data Automatic measurement and interpretation of ecg waveform Rs232 interface and optional software supporting data transmission to pc Isolated input circuit with protection against defibrillation and pacemaking Ac power/(built in rechargeable li ion battery supporting 1 hour operation) Ac, emg, dft filter; paper size: 63mmx20m (roll type) Package for 1 unit:24x31x37cm gw:6kgs nw:5kgs Package for 4 units:60x40x53cm gw:26kgs nw:24kgs
Ecg-9012 Twelve channel with interpretive Build in rechargeable li battery Chinese/english language Simultaneous 12 leads 320x240 graphic lcd, 3.8 inch screen Paper size: 216mmx20/30m With rs232/usb interface 128 patients save With 2 years guarantee of the main unit and 1 year of the accessory.
Single channel digital ECG machine with measurement Simultaneously 12 leads acquisition Multiple operation mode (Manual/Auto/Ref.lead) LCD to display operation status Built-in standard RS232 Interface DC/AC power with built-in rechargeable Ni-MH battery
ECG Three channel Interpretive ECG machine Simultaneously 12 leads acquisition Multiple operation mode (Manual/Auto/Ref.lead) LCD to display operation status and ECG waveform Built-in standard RS232 Interface (USB is optional) DC/AC power with built-in rechargeable lithium battery
Single Ch. ECG Single channel digital ECG machine with measurement Simultaneously 12 leads acquisition Multiple operation mode (Manual/Auto/Ref.lead) LCD to display operation status Built-in standard RS232 Interface DC/AC power with built-in rechargeable Ni-MH battery
Ecg-903a Standard 12 leads Manual mode, 3 auto modes Ac/emg filter 63mmx20/30m, roll paper Display menu, operation status and ecg waveforms 375x295x450mm 4.5kg
Ecg-901a 50mmx20/30m, roll paper Rechargeable ni-mh battery Display menu, operation status and ecg waveforms 380x300x210mm Gross weight:4.3kg
High-conductivity gel for electrocardiography (ECG) is a specialized conductive gel used to improve electrical conductivity between the skin and ECG electrodes during cardiac monitoring procedures. Here's more information about high-conductivity gel for ECG: Purpose: The primary purpose of high-conductivity gel is to reduce impedance and improve the transmission of electrical signals between the skin and the ECG electrodes. This ensures accurate and reliable recording of the heart's electrical activity during ECG testing. Composition: High-conductivity gel is typically water-based and contains conductive agents that enhance its electrical conductivity properties. Common ingredients may include water, glycerin, propylene glycol, carbomer, electrolytes (e.g., sodium chloride), and preservatives. Conductivity: High-conductivity gel is formulated to have superior electrical conductivity compared to standard ECG gels or other electrode contact solutions. This allows for better signal quality and minimizes the risk of artifacts or interference during ECG recordings. Viscosity: The gel's viscosity is designed to be suitable for easy application and spreadability on the skin. It should be thick enough to adhere to the skin and maintain contact with the electrodes but not too thick that it hinders electrode placement or skin contact. Non-Staining: High-conductivity gel is typically formulated to be non-greasy and non-staining, ensuring minimal residue on the skin after use. This helps maintain patient comfort and prevents staining of clothing or bedding. Compatibility: High-conductivity gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with standard ECG machines and Holter monitors. Application: Before applying the gel, the skin should be cleaned to remove any oils, lotions, or dirt that may interfere with electrode contact. A thin layer of high-conductivity gel is then applied to the skin at the electrode sites before attaching the electrodes. Hygiene: High-conductivity gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Overall, high-conductivity gel plays a crucial role in ensuring optimal electrode-skin contact and signal quality during ECG testing. Its superior conductivity properties make it an essential accessory in cardiac diagnostic procedures, allowing for accurate interpretation of the heart's electrical activity.
ECG gel, also known as electrocardiogram gel or EKG gel, is a conductive medium used in electrocardiography (ECG) procedures to improve the quality of electrical signal transmission between the skin and the electrodes of the ECG machine. Here's more information about ECG gel: Purpose: The primary purpose of ECG gel is to enhance the conductivity and reduce impedance between the skin and the ECG electrodes. This improves the quality and accuracy of the electrical signals detected by the electrodes, resulting in clearer and more reliable ECG readings. Composition: ECG gel is typically a water-based, conductive gel formulated to be non-greasy, non-staining, and hypoallergenic. It may contain ingredients such as water, glycerin, propylene glycol, carbomer, preservatives, and conductivity-enhancing agents. Conductivity: ECG gel is formulated to have high electrical conductivity, allowing it to effectively transmit electrical signals between the skin and the electrodes. This conductivity helps minimize impedance and artifacts, ensuring accurate ECG readings even in challenging conditions. Viscosity: ECG gel is usually designed to have a suitable viscosity that allows for easy application and smooth spreading on the skin. It should be thick enough to stay in place during the procedure but not so thick that it hinders electrode placement or skin contact. Compatibility: ECG gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with both standard ECG procedures and specialized cardiac tests such as stress tests, Holter monitoring, and echocardiography. Application: ECG gel is applied directly to the skin at the electrode sites before attaching the electrodes. A sufficient amount of gel should be applied to ensure good contact between the electrodes and the skin surface. Excess gel can be wiped away after electrode placement. Hygiene: ECG gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Removal: After the ECG procedure, any remaining gel should be wiped off the skin using a clean, dry cloth or disposable wipe. Residual gel left on the skin can cause discomfort or irritation if not properly removed.
An ECG bulb with an electrode cup is a component used in electrocardiogram (ECG) machines for detecting and recording the electrical activity of the heart. Electrode Cup: The electrode cup is the part of the ECG bulb that makes direct contact with the patient's skin. It is designed to provide a conductive interface for accurately capturing the electrical signals produced by the heart. Material: The electrode cup is usually made of metal or a conductive material that ensures good electrical conductivity and signal transmission. The bulb portion may be made of plastic or silicone, providing flexibility and durability. Compatibility: ECG bulbs with electrode cups are designed to be compatible with specific models of ECG machines. They may come in different sizes and configurations to fit various electrode placements and patient needs. Application: During an ECG procedure, the ECG bulb with an electrode cup is placed on the patient's chest, limbs, or other specific locations as directed by the healthcare provider. The electrode cup makes contact with the skin, allowing the ECG machine to detect and record the electrical activity of the heart. ECG bulbs with electrode cups are essential components of ECG machines, providing a reliable interface for capturing the electrical signals of the heart during diagnostic procedures. Their design, material composition, and compatibility with ECG machines make them valuable tools in cardiovascular healthcare settings.
An ECG bulb, made of silicone, is a component used in certain types of electrocardiogram (ECG) machines. Here's more information about ECG bulbs made of silicone: Material: ECG bulbs made of silicone are designed to be flexible, durable, and resistant to wear and tear. Silicone is chosen for its properties, including flexibility, biocompatibility, and resistance to temperature extremes and chemical exposure. Purpose: The ECG bulb, also known as an ECG electrode or sensor, is a crucial component of the ECG machine. It serves as the interface between the patient's skin and the machine's electrical circuitry, allowing the machine to detect and record the electrical signals produced by the heart. Design: ECG bulbs made of silicone typically have a bulbous or rounded shape with a flat surface that comes into contact with the patient's skin. The silicone material provides a comfortable and secure fit while ensuring good electrical conductivity for accurate signal transmission. Compatibility: Silicone ECG bulbs are designed to be compatible with specific models of ECG machines. They may come in different sizes and shapes to accommodate different electrode configurations and patient needs. Hygiene: Silicone ECG bulbs are often designed for single-use or disposable use to maintain hygiene and prevent cross-contamination between patients. Disposable ECG bulbs help reduce the risk of infection transmission in clinical settings.
ECG Snap Electrode 3M Red Dot Monitoring Radiolucent Foam Backing 10 per Pack, 5 packs/bag, 20 bag/cs UOM: 1000/CS Product Number: 2570 Manufacturer: 3M
ECG Snap Electrode Dyna Trace Monitoring Radiolucent Foam Backing 3 per Pack UOM: 600/CS Product Number: 1500-003 Manufacturer: Conmed