Key features: 1.Robust design, over pressure protected 2.Maintenance free through wear-free inductive pickup mechanism 3.Switchable pressure units 4.Optional signal output with possibility of characteristic curve spread and reversal with any offset 5.Characteristic curve implementation via table with max. 30 measuring points 6.Complete adjustment of all parameters and measuring point protocol possible through 7.Optional pc adaptor eu03 8.Large led display Key specifications: 1.Measuring range: 0 ~ 160 mbar to 0 ~ 600 mbar 2.Maximum static operating pressure: 40 bar 3.Overload capacity: single sided overpressure proof upto the rating of measuring system, (+) and (-) side, vacuum proof 4.Straight line error (max): , ± 2.5% full scale 5.Temperature drift: 0.8% full scale / 10k 6.Pressure connection: female thread g 1/4 without optional cutting ring fitting for 6 or 8 mm tube 7.Operating ambient & media temperature: -20, ° c to +70, ° c 8.Protection class: ip65 per din en 60529 9.Electrical output: (0) 4-20ma, 0-10v, 3 , ?? wire 10power supply: 24 v dc/ ac 11.Switching contacts: 2 sets of programmable voltage free contacts: no or nc 12.Display: 3 1/2 digit led display 13.Electrical connections: two round shell multi-pin connector sockets (m12, male) 14.Material, housing: polyamide pa 6.6 15.Measuring element: brass, viton, epdm Application areas: 1.Flow rate and volume monitoring of air, gaseous media in ducts 2.Filling level monitoring of tank / containers for liquefied gases (n2, o2, argon and co2) 3.Compressor monitoring and control Industrial areas: 1.Air conditioning and ventilation systems 2.Hvac and ventilation application 3.Environment monitoring 4.Clean room and laboratory rooms