Applications: Designed for handling condensate in the steam and water circuit systems of the thermal power stations that burn organic fuel. May be also used to transfer water in heating plants and water supply systems. Performance of the Pump: Capacity, Q = 80 m3/h, Head, H = 155 m, Speed of rotation, 2940 rpm, NPSHr = 1.6 m The pump as a component of the pump unit is an electrically driven horizontal multistage ring-section centrifugal pump between bearings, with single flow impeller arrangement. The suction casing, delivery casing and stage casings are bolted together with tie bolts to form a pump casing. The suction nozzle integrally cast with the suction casing is located horizontally at side (radially to the pump centerline). The discharge nozzle integrally cast with the delivery casing is oriented vertically upwards. The pump casing is supported at the bottom with feet integrally cast with the suction and delivery casings. The pumping unit alignment is maintained during its operation due to dowelling the delivery casing to the baseplate, whilst the other end of the pump can slide axially thus allowing for free expansion of static components.