Adopt latest CT technology and integrated mask digital technology
Wireless transmission distance 30m, can transmit through building barriers
Integrated design ensures uninterrupted year-round high precision, high reliability and high stability test.
Have peak value maintaining, data maintaining, data memory function
Easy to install and remove with power on
Insulation rod has the characteristics of moisture resistance, high temperature resistance, impact resistance, bending resistance, high insulation and scalability.
Can accurately measure 0.00mA-1200A current or leakage current
Can test high and low voltage changing ratio, respectively test the first loop and secondary loop high and low voltage current, and then obtain the voltage change through manually calculation.
PARAMETERS
Electrical parameters
Power supply Ammeter: DC6V Alkaline Dry Battery (1.5V AAA X 4),
Receiver: DC7.5V Alkaline Dry Battery (1.5V AA X 5),
working 10 hours
Test mode Clamp CT, integral approach
Transmission mode Wireless transmission, the maximum distance of straight line transmission is about 30m
Display mode 4 bit LCD display, with backlight function
Sampling rate 2 times/second
Measurement scope 0.00mA-1200A (50/60Hz automatic)
Resolution 0.01mA
Shift 0.00mA-1200A automatic shift
Accuracy (23±5C, below 70%RH) 0.000mA-120.00A: ±1%±3dgt
120.00A-1200.0A: ±1%±5dgt
Line voltage Below 69KV line test (with 5 insulation rods operation)
Data memory 99 sets
Automatic shutdown 15 minutes after boot
Battery voltage