This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, allergies and other respiratory diseases and disorders. The compressor forces air through the tubing to the nebulizer. When the air enters the nebulizer it converts the prescribed medication into a mist of microscopic droplets that are suitable for easy inhalation.
Model: RJ-206D
Power: AC220V/50Hz
Motor: oil-free ball bearing piston
Sound level: â?¤55dB
Max pressure range: â?¥0.22Mpa
Free air flow: 14 lpm
Nebulizing rate: â?¥0.26ml/min
Medication size: 3~5um(75%)
size:223*150*110mm
COMPRESSOR Brand: OEM Original: China -26/30 mm stamping with rising temperature 180 -3 bearings in motor and metallic thermal rotector(not disposable plastic type) Input: AC 120V/60Hz Extreme pressure:>205 kpa Power consumption: �200VA Medication capacity: 6ml Particle size: �5 μm & 60% MMAD: 2.0 μm. Average nebulization rate: �0.2 mL/min Noise Level: �60 dB Compressor Pressure Range: 30-58 psi Operating Pressure Range: 7-10 psi Liter Flow Range: 6-10 LPM Operation mode: 20 minutes on, 40 minutes off Operation Temperature Range: 10 to 40(50 to 104) Operation Humidity Range: 30 to 75% RH One set nebulizer kits includes: -1pc adult mask, 1 child mask - 1pc mouth piece - 5 filters - 1 pc 1.2M tube
Nebulizer Kit with Face Mask Product Code: MED 107 Specifications: Sterile, individually packed in a polybag Size/Strength: Adult, Pediatric Description Transparent mask (with holes) made from non-toxic, medical grade PVC. Nebuliser chamber (7ml) to house the drug in liquid form with a funnel shaped vent to allow oxygen at high flows to convert the liquid drug into droplet form to reach the lungs. Soft, kink resistant, 180cms long non-collapsible extension tubing (STAR LUMEN) to be connected with the oxygen source. Swivel connector for patient comfort. Elastic Strap provided to position the mask properly.
This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, allergies and other respiratory diseases and disorders. The compressor forces air through the tubing to the nebulizer. When the air enters the nebulizer it converts the prescribed medication into a mist of microscopic droplets that are suitable for easy inhalation. The nebulizer system comes with the following components: Compressor Machine Nebulizer Kit Air Tubing Air Filter Fuses Instruction Manual Power: AC220V/50Hz Motor: oil-free ball bearing piston Sound level: 55dB Max pressure range: 0.22Mpa Free air flow: 14 lpm Nebulizing rate: 0.26ml/min Medication size: 3~5um(75%) size:180*180*100mm
Pressure range 1. Under normal working conditions, the pressure range of the device is 60kPa 130kPa. 2. When the pipeline blockage occurs etc. in the device, the pressure produced by the device will not break in the range of 130kPa ~ 400kPa 3. Residual liquid volume 0.7mL 4. Machine noise Noise of machine in normal operation: 65dB (frequency-weighting characteristic A). 5. Enclosure leakage current Normal condition 0.1mA; Single fault condition 0.5mA 6. Patient leakage current Normal condition 0.1mA; Single fault condition 0.5mA. 7. Droplet particle size 1um-5um
Pressure range 1. Under normal working conditions, the pressure range of the device is 60kPa 130kPa. 2. When the pipeline blockage occurs etc. in the device, the pressure produced by the device will not break in the range of 130kPa ~ 400kPa 3. Residual liquid volume 0.7mL 4. Machine noise Noise of machine in normal operation: 65dB (frequency-weighting characteristic A). 5. Enclosure leakage current Normal condition 0.1mA; Single fault condition 0.5mA 6. Patient leakage current Normal condition 0.1mA; Single fault condition 0.5mA. 7. Droplet particle size 1um-5um
Pressure range 1. Under normal working conditions, the pressure range of the device is 60kPa 130kPa. 2. When the pipeline blockage occurs etc. in the device, the pressure produced by the device will not break in the range of 130kPa ~ 400kPa 3. Residual liquid volume 0.7mL 4. Machine noise Noise of machine in normal operation: 65dB (frequency-weighting characteristic A). 5. Enclosure leakage current Normal condition 0.1mA; Single fault condition 0.5mA 6. Patient leakage current Normal condition 0.1mA; Single fault condition 0.5mA. 7. Droplet particle size 1um-5um
Pressure range 1. Under normal working conditions, the pressure range of the device is 60kPa 130kPa. 2. When the pipeline blockage occurs etc. in the device, the pressure produced by the device will not break in the range of 130kPa ~ 400kPa 3. Residual liquid volume 0.7mL 4. Machine noise Noise of machine in normal operation: 65dB (frequency-weighting characteristic A). 5. Enclosure leakage current Normal condition 0.1mA; Single fault condition 0.5mA 6. Patient leakage current Normal condition 0.1mA; Single fault condition 0.5mA. 7. Droplet particle size 1um-5um
Pressure range 1. Under normal working conditions, the pressure range of the device is 60kPa 130kPa. 2. When the pipeline blockage occurs etc. in the device, the pressure produced by the device will not break in the range of 130kPa ~ 400kPa 3. Residual liquid volume 0.7mL 4. Machine noise Noise of machine in normal operation: 65dB (frequency-weighting characteristic A). 5. Enclosure leakage current Normal condition 0.1mA; Single fault condition 0.5mA 6. Patient leakage current Normal condition 0.1mA; Single fault condition 0.5mA. 7. Droplet particle size 1um-5um
Power 130VA Operation Environment Temperature: 5 40. Relative humidity: 80%. Atmosphere pressure: 80.0kPa 106.0kPa Spray rate:The spray rate should be 0.2mL/min. Airflow volume: Compressed airflow of compression pump: 8L/min. transport and storage: 93%