MPVCS-01 this product has good mechanical physical performance and extrusion processing performance, and it is suitable for the sheath material of wire and cable with low temperature of 70.
MPVCS-01 this product has good mechanical physical performance and extrusion processing performance, and it is suitable for the sheath material of wire and cable with low temperature of 70ºC. Properties Typical Value Test Method Appearance Black granule Visual Density /(g/cm3)
Low insertion loss. High return loss. High reliability and stability. Excellent exchangeability and durability. FC, LC, SC, ST, MU, MTRJ, E2000, DIN, D4, SMA, ESCON, FDDI, MPO etc. is available. PC, UPC or APC polishing. Single mode and multi-mode available. Simplex, duplex or fan-out available. ;0.9, ;2.0, ;3.0 available. Length: 1m, 1.5m, 2mor customized. PVC, LSZH or hytrel available. Fully compliant with the standards of Telcordia GR-326-CORE and RoHS.
This cable has been designed for long haul direct / backbone application. Our stranded loose tube design provides stable performance over a wide temperature range and is compatible with any telecommunications-grade optical fiber. Direct Buried type Fiber Optical Cables are designed for easy and economical installation. The stranded loose tubes contain thixotropic jelly but the cable core is based on dry-block construction. Incorporation of Dry Water Block Technology eliminates the need for traditional jelly filled water blocking methods, thus providing efficient and craft-friendly cable installation. The thixotropic jelly is used to fill the buffer tubes to prevent water ingress. Steel Tape Armoring provides a rodent protection, length markings in meters for easy determination of cable length. Extra Strength cable can also be delivered with Peripheral Strength Members. Features & Application òExcellent optical, mechanical & environmental performance òHigh strength-to-weight ratio òCSM dielectric type û Fiber Reinforced Plastic òDry block construction òHigh tensile strength òHigh crush strength òCorrosion resistance òKINK resistance òVery light weight òVery flexible & small bending radius òLong haul / backbone application òJunction communication systems òAll dielectric applications òCATV applications. Construction Parameters Fiber Count 02 û 144 Fibers Color of Loose Tube Blue , Orange , Green , Brown , Grey , White, Red & Black Loose Tube Material Polybutylene Terephthalate (PBT) Loose Tube Filling Material Thixotropic Jelly Filler Material Medium Density/High Density Polyethylene (MDPE/HDPE) Central Strength Member Fiber Reinforced Plastic (FRP) û Non Metallic Core Moisture Protection Methodology Dry Block Design, Water Blocking Yarns/Tapes Second (Outer) Sheath Material High Density Polyethylene (HDPE) Printing on Outer Sheath Engraved Hot Foil or Inkjet Printing Nominal Cable Delivery Length (km) 4 KM ¦ 3%.
This cable has been designed for long haul direct / backbone application. Our stranded loose tube design provides stable performance over a wide temperature range and is compatible with any telecommunications-grade optical fiber. Direct buried type fiber optical cable are designed for easy and economical installation. The stranded loose tubes contain thixotropic jelly but the cable core is based on dry-block construction. Incorporation of dry water block technology eliminates the need for traditional jelly filled water blocking methods, thus providing efficient and craft-friendly cable installation. The thixotropic jelly is used to fill the buffer tubes to prevent water ingress. Steel tape armoring provides a rodent protection, length markings in meters for easy determination of cable length. Extra strength cable can also be delivered with peripheral strength members. Features & application Excellent optical, mechanical & environmental performance High strength-to-weight ratio Csm dielectric type û fiber reinforced plastic Dry block construction High tensile strength High crush strength Corrosion resistance Kink resistance Very light weight Very flexible & small bending radius Long haul / backbone application Junction communication systems All dielectric applications Catv applications. Construction Parameters Fiber Count As per CustomerÆs Requirement No. of Loose Tube As per CustomerÆs Requirement G.655 As per CustomerÆs Requirement G.652 As per CustomerÆs Requirement Loose Tube Material Polybutylene Terephthalate (PBT) Loose Tube Filling Material Thixotropic Jelly Filler Material Medium Density/High Density Polyethylene (MDPE/HDPE) Central Strength Member Fiber/Glass Reinforced Plastic (FRP/GRP) Armoring Corrugated Steel Tape Armoring Peripheral Strength Member (if required) Aramid / Glass Yarn Core Moisture Protection Methodology Dry Block Design, Water Blocking Yarns/Tapes Outer Sheath Material High Density Polyethylene (HDPE) Printing on Outer Sheath Engraved Hot Foil or Inkjet Printing Nominal Cable Delivery Length (km) 4 KM ¦ 3%.
Product description This cable has been designed for aerial application with flat type construction. Our stranded loose tube design provides stable performance over a wide temperature range and is compatible with any telecommunications-grade optical fiber. This aerial type fiber cable is designed for easy and economical installation with a sufficient tensile strength to overcome wind pressures and ice loadings. Features & application Excellent optical, mechanical & environmental performance Csm dielectric type û fiber reinforced plastic High tensile strength High crush strength Aerial application Application in lan, wan, especially in ftth networks Easy to clamp and install Can bear ice loads and high wind pressures. Construction Parameters Fiber Count 02 to 12 Fiber Fiber Type G.652.D Loose Tube Material Polybutylene Terephthalate (PBT) Loose Tube Filling Material Thixotropic Jelly Sheath Material High Density Polyethylene (HDPE) Printing on Outer Sheath Engraved Hot Foil or Inkjet Printing Nominal Dimensions Width : 7.0 + 0.5mm , Height : 3.5 + 0.3mm Nominal Cable Delivery Length (km) 2 KM + 3% . Mechanical Characteristics Tensile Strength (N) 600 Tensile Strength (N) (Installation) 1000 Crush Strength (N) 2,000 Minimum Bending Radius (mm) 75 Temperature Operating Range -10 to +70¦C.
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Application :- These single core flexible cables are used for wiring in control panels, machines and various electrical installations In small, medium and large industries. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house which is impervious to water, oil, grease, acids, etc. and are tough to protect from any mechanical abuses. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 50.00 Sq. mm with ISI mark & 70.0 to 40.0 Sq. mm generally conforming to IS:694 Color Codes : Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.