FDR-2001 Petroleum products and additives mechanical impurities analyzer
Scope
This instrument conforms to the standards GB/T511. It is suitable for the determination of all kinds of light oil, heavy oil, lubricating oil and additives in petroleum products.
Features
1, the instrument adopts the pre heating, testing and integration of structural design, reasonable structure, beautiful appearance, reliable quality.
2, the circuit uses the temperature control table to control the electric heating board temperature, the heating plate temperature is constant temperature and controllable, in order to meet the needs of the test.
3, the instrument uses a solid state voltage regulator to adjust the input voltage, so as to control the size of the heating power, to achieve the purpose of heating insulation funnel.
4, the filter device is connected with the suction filter by the vacuum pump, it can measure the sample which is difficult to filter.
Technical Parameters
1 Power supply: AC 220V ± 10%, 50Hz.
2, water bath heating power: 1000W.
3, the water bath temperature range: room temperature ~90 adjustable.
4, the water bath temperature display: LED digital display.
5, water bath temperature control accuracy: ± 1 .
6, the funnel temperature range: room temperature ~90 adjustable.
7, the funnel temperature display: LED digital display.
8, the funnel temperature control accuracy: ± 2 .
9, Dimensions: control box: 390 (L) 260 (W) 590 (H);
Water bath box: 90 (L) 290 (W) 370 (H).
10, Ambient temperature: 35 .
11, relative humidity: 85%.
12. Total power consumption: less than 1200W.
Scope Petroleum products and additives mechanical impurities analyzer is based on national standards GB/T511 "Petroleum products and additives mechanical impurities Assay (gravimetric method)" requirements set designed for the determination of various types of light petroleum products, heavy oil, lubricants and additives mechanical impurities. Features 1. Preheat take the test integrated structure design, reasonable structure, beautiful appearance, reliable quality. 2, the circuit temperature controller to control electric heating plate temperature, thermostat controlled heating plate temperature, in order to meet the test needs. 3, the use of solid state voltage regulator input voltage Insulation funnel to control the size of the heating power to achieve the required temperature insulation funnel purposes. 4, filtration devices connected by a vacuum pump and suction flask, adequate protection of the measurement sample is difficult to filter. Technical Parameters 1 Power supply: AC 220V ± 10%, 50Hz. 2, water bath heating power: 1000W. 3, the water bath temperature range: room temperature within ~90 ? adjustable. 4, the water bath temperature display: LED digital display. 5, water bath temperature control accuracy: ± 1 ?. 6, the funnel temperature range: room temperature within ~90 ? adjustable. 7, the funnel temperature display: LED digital display. 8, the funnel temperature control accuracy: ± 2 ?. 9, Dimensions: control box 390 (length) × 260 (width) × 590 (H); Water bath 90 (L) × 290 (width) × 370 (high). 10, Ambient temperature: =35 ?. 11, relative humidity: =85%. 12 Total power consumption: less than 1200W.
Scope Petroleum products and additives mechanical impurities analyzer is based on national standards gb / t511 "petroleum products and additives mechanical impurities assay (gravimetric method)" requirements set designed for the determination of various types of light petroleum products, heavy oil, content lubricants and additives mechanical impurities. Features 1. Preheat take the test integrated structure design, reasonable structure, beautiful appearance, reliable quality. 2, the circuit temperature controller to control electric heating plate temperature, thermostat controlled heating plate temperature, in order to meet the test needs. 3, the use of solid state voltage regulator input voltage insulation funnel to control the size of the heating power to achieve the required temperature insulation funnel purposes. 4, filtration devices connected by a vacuum pump and suction flask, adequate protection of the measurement sample is difficult to filter. Technical parameters 1 power supply: ac 220v ± 10%, 50hz. 2, water bath heating power: 1000w. 3, the water bath temperature range: room temperature within ~90 ? adjustable. 4, the water bath temperature display: led digital display. 5, water bath temperature control accuracy: ± 1 ?. 6, the funnel temperature range: room temperature within ~90 ? adjustable. 7, the funnel temperature display: led digital display. 8, the funnel temperature control accuracy: ± 2 ?. 9, dimensions: control box 390 (length) × 260 (width) × 590 (h); Water bath 90 (l) × 290 (width) × 370 (high). 10, ambient temperature: =35 ?. 11, relative humidity: =85%. 12 total power consumption: less than 1200w.
Commodity: Dicalcium phosphate Feed Grade Use DCP is the feed preparation of raw materials, Animal right to supplement calcium needs. Coarse its products more applicable to the preparation hens, ducks feed, concentrate feed and premix. Product Nature Molecular Formula:CaHPO4·2H2O,Molecular weight:172.09,After drying with loose white powdery crystals or granules. Neutral products, the melting acid, water-soluble, hygroscopicity small, heated to 90 around gradually lose water of crystallization. Product Features The purity of the product, calcium and phosphorus ratio appropriate to ensure a higher degree of its biological effects. Phosphorus content greater than 18% of the products, due to a small amount of MCP, and its biological effects better. This unique high-tech companies use technology to make our products crystallization, high purity and its harmful impurities significantly below standards:HG26362000 Drying process advanced products, products with low free water under the premise that the product does not lose crystallization of water, avoid the product in the drying process for the loss of water caused by crystallization of biological effects of the reduction. Coarse particle DCP in the animals stay in the stomach longer and more conducive to the absorption of calcium phosphate, the product of Micro-particle DCP granulation from mechanical, without any chemical binder. Specifications Appearance white and gray powder/granule Total P 18% min Calcium 21% min F 0.18% max As 30 ppm max Pb 30 ppm max Packing and Storage Knitted bags lined polyethylene plastic bags double packaging, Weighing 25Kg/50KG/1000Kg. Transportation-and harsh rain. Stored in a cool, ventilated, dry place.
Polyacrylamide is a synthetic polymer composed of acrylamide monomers and is widely used in various industrial, environmental, and scientific applications. It comes in various forms, including powder, liquid, and gel. In water treatment, polyacrylamide is employed as a flocculant and coagulant to separate and remove suspended particles and impurities, aiding in the purification of drinking water and wastewater treatment. Additionally, it plays a crucial role in the petroleum industry for enhanced oil recovery and in agriculture for soil conditioning and erosion control. In the laboratory, it serves as a gel for electrophoresis in DNA and protein analysis. Its versatility in facilitating solid-liquid separation and its ability to modify the rheological properties of fluids make polyacrylamide a valuable polymer in a range of practical applications.
Anionic polyacrylamide is a water-soluble synthetic polymer with negatively charged functional groups, widely used in industries and environmental applications. Its main role is as a flocculant and coagulant in water treatment processes, where it aids in the aggregation and settling of suspended particles, impurities, and solids, facilitating their removal and purification from water sources. Beyond water treatment, anionic polyacrylamide has applications in enhanced oil recovery in the petroleum industry, soil conditioning for agriculture, and enhancing particle retention and drainage in the paper and textile industries. Its versatility in improving solid-liquid separation and reducing environmental contamination makes it a critical component in various industrial and environmental processes.
Scope Petroleum products vacuum distillation analyzer is based on national standards gb / t9168 "petroleum products - determination of distillation under reduced pressure" design, manufacture. For the determination of the maximum temperature of the liquid reaches 400 ?, can be partially or completely evaporated boiling range of petroleum products under reduced pressure. Features Equipment and inputs by the host refrigeration apparatus of two parts. Host by the bath, temperature control portion, glassware, balance tank, the pressure regulating system, solenoid valves, electric heaters and other components. Its main features are as follows; 1, the main instrument is compact, attractive appearance, easy to operate, bath and end table made of stainless steel, corrosion resistance. 2, bath temperature by a digital temperature controller temperature control, temperature control table can visualize circulating water temperature, and can accurately control the temperature. 3, by the vacuum pump, pressure regulating system pressure system, solenoid valves, balance tanks and other components, make the pressure constant within a predetermined range. 4, the flask was heated furnace using a parallel structure, uniform heating, electric can adjust up and down, and with a fan to cool it quickly. 5, into the cold trap by the refrigeration apparatus cooling, convenient and reliable. Technical parameters 1, power: ac220v ± 10% 50hz 2, input power: 1900w host instrument into refrigeration 300w 3, the water bath temperature range: room temperature ~ 99.9 ? 4, temperature control accuracy: ± 2 ? 5, adjusting the pressure range: ac10 ~ 220v 6, pressure adjustment range: 1mmhg ~ 4mmhg 7, the outer shape dimensions: 720x420x680mm
Supplier: Fuel Dispenser, Tank, Skid Mounted Gas Station, Submersible Pump, Liquid Gauge.
Supplier: Petroleum Equipment Products Operation Equipment Trucks And Nitrogen Generating Trucks; Natural Gas Compressor Equipment; Oil And Gas Production And Processing Technology Systems; Natural Gas Liquefaction Equipment; Wellheads And Well Control Systems; Oil Extraction Machinery.
FDR-1701 petroleum products residual carbon analyzer (Ramsbottom method) Overview The instrument complies with the standards ASTM D524 and ISO4262. The standard specifies the amount of residual carbon remaining after evaporation and pyrolysis of the oil and provides some relative coking tendency. It is generally suitable for nonvolatile petroleum products which are partially decomposed at atmospheric pressure. The instrument consists of metal coking furnace, electric control box, sample loader, control ball and glass coking bottle and other components, temperature control part of the use of precision intelligent digital pressure heating, so that the furnace temperature rise evenly, Also used another piece of intelligent digital temperature controller as a coking bottle for temperature calibration use, so the instrument design is reasonable, accurate temperature control. Technical Parameters 1, input power: 220V ± 10% 50HZ 2, the furnace temperature: 550 ± 5 3, heating furnace power: 1500W 4, check the temperature: in line with the standard test method 5.2 requirements 5, coking hole hole: 5 holes 6, sample loader hole: 5 holes 7, the timer: every 20 minutes, 30 minutes once a newspaper 9, ambient temperature: room temperature 25 or so 10, relative humidity: