To calculate dielectric constant of solids. The instrument consists of high frequency oscillator of tuneable frequency, optimum tunning of oscillator can be measured using outer gang condenser. Dielectric is placed between parallel plates, change is detected and difference is noted for calculation.
Low dielectric glass fiber DW140 is made of special glass fiber, which has lower dielectric constant and dielectric loss than alkali-free glass fiber, and lower density. The thickness of electronic-grade glass fiber cloth is 0.14mm, and other varieties can also be produced: untwisted yarn, chopped strand, electronic-grade glass fiber yarn. SG Three-phase Dry Type Transformer SG-3KVA 400/20 V headlamp H7R.2 Globe Valve Seals kit 11G4DJ-1055F-14-1 MONITOR JZ-MC-V Thermo meter WTYY-1021 Modun u ra (U52) ADAM-4068 Filter element of Air filter nozzle oil pump SDSGLQ-68T-40 Level Gauge BNA15/16-MG-M900-V60-MRA-3/M/1-ZTSS200(V0.85)MG-AU-VK10-TS-M900/25(KCY-15/16-900/3/10) Low dielectric glass fiber cloth DW140 Card for controller B-A/D U13 Position Sensor of Blade MK4-A-B-800-N angular contact ball bearing 7214 BECBM Analog Signal MBD 201 Rectifier signal instruction card A55 SERVOVALVE HYDRAULIC G771K208 Lamp (Red) APS122DNR VALVE NEEDLE J23W-160P Displacement Sensor (LVDT) TDZ-1E-03 DIFFERENTIAL PRESSURE TRANSMITTE 3051CD2A22A1AI1M5D4Q4DFP9HR5 Power alarm board SDP-PR-3AY BREAKER AUXILIARY SWITCH CONTACTS FK10-II-50 PUMP DOSING S1CBH07065PVT8000UA01080EN Three-phase active power measurmnet transducer TS20-WD-3AS-165A4BN MEDIA CONVERTER EMC-02-RX SENSOR, VIBRATION VELOCITY SDJ-SG-2H Blind-free two-color water meter B69H-32/2-W bladder NXQ-AB-25-31.5-L-Y Adhesive insulation component B J793B HSNH440Q2-46NZ ELECTRO STATIC PRECIPITATOR CONTROLLER EPCS-II Liquid Leakage Detector of Generator YTG-B CELL BASAH BATTERY N 200 - 190H52 SERVO CARD DMSVC005 Oring for pump 7LDTNB-6 Flow equalize board SDP-PR-3N SENSOR MEASURING ZS04 Gaskets TN-9001 Mechanical seal for pump 65AY60 Level Transmitter ABDA6CGJ1+AAZ1 LVDT FOR HP Quick closing Valves HL-3-100-15 cam bien ap luc truoc luoi chan rac MPM426W Low dielectric glass fiber cloth DW140 DF2022-2-12-JERRY
We bring forth high quality Laboratory Testing Instruments, which are manufactured in compliance with industry standards. The Laboratory Testing Instruments offered by us, is highly appreciated among the clients owing to their high performance and longer working life .Further, the Instruments are offered in various specifications. Leaders in manufacturing and supplier of laboratory Testing Instruments : Overhead Lab Stirrer volt Model -3A(G), 4A(G), 6A(G). Overhead Lab Stirrer Model 3A,4A, 6A. Automatic Karl Fischer Hot Air Oven Digital. Vacuum Oven Round Digital ,Vacuum Oven Digital Rectangular,Hot Air Oven Top Motor Digital K. F. App. Precision Digital Melting /Boiling Point App. Autoclave , Autoclave Portable ,BOD Incubator,Environmental Chamber Digital Rate Test App Single State Water Still , Heating Mental Hot Plate Rectangular, Sieves Shaker, Bacteriological Incubator ,Water Bath Shaker pH Meter Digital Manual Temp. Comp. Mdl. pHM pH Meter digital Auto cum Manual Temp Comp. Mdl pHAM Muffle Furnace Digital , Oil. Bath Draining & Drying Rack, Digital Colony Counter, Orbital Shaker Incubator, Bulk Density App. Digital Antibiotic Zone Reader ,Digital Conductivity Meter, Griffin Flask Shaker, Rotary shaker Soxhlet Extraction Heater Hot Plate & Mantle Type IR Moisture Balance, Ultrasonic Bath ,Platform Shaker Constant Temp- Circulating Water Bath Hot Plate Round ,Tablet Hardness Taster Monsanto Rotary High Vacuum Pump Dissolution Apparatus Single & Three Stage Dissculution Rate Test Apparatus 6 test. Binocular Microscope Ford Flow Cup Viscometer Low Temp. Bath , Tablet Distigration Test , Friability Test Apparatus Viscometer Bath ,Deep Freezer Instrument Sterilizer , Leak Test Apparatus , Water Bath Thermostatic. Electric Bunsen Burner with Regulator Box Peristaltic Pump Water bath Dye Pots Multi Magnetic Stirrer Digital Tablet Disintegration, Hot Plate Magnetic Stirrer , Laboratory Centrifuge , Laminar Flow Tablet Hardness Tes
Conforms to is: 10050-1981, & astm d 4644 This apparatus is used to assess the resistance offered by a rock sample to weakening and disintegration when Subjected to drying and wetting in a slaking fluid, usually water. The equipment meets the essential Requirements of is:10050 -1981 & astm d 4644 and comprises the following: A motor drive with reduction gear mounted on a base board and capable of rotating four drum assemblies at a Constant speed of 20 rev/min approximately. The motor drive is totally enclosed in a hinged cover for quick Accessibility. An operating switch is provided in the cover. Two / four test drums made of brass wire mesh, with one end closed and having a removable cover on the other End. They have suitable couplings for mounting in the perplex water troughs. The drums are 140 mm in diameter And have an unobstructed length of 100 mm. Two / four perplex water troughs, accommodate one test drum each. These drums carry quick couplings on either End which are in turn coupled with couplings of the motor drive. The troughs allow 40 mm unobstructed clearance Below the test drum. A water level mark is provided in each water trough 20 mm below the axis of rotation of the Drum. Suitable for operation on 220 volts, 50 hz, single phase ac supply. Order code Lisc-557a Lisc-557b No. Of test drums 2 4
Fireplace glass Features: Our flat borosilicate 3.3 float glass sheet is equivalent with schott's borofloat series. Mechanical performance Density 2.23+/-0.02g/cm3 Thermodynamic performance Thermal expansion coefficient (0-300) 3.3+/-0.1x10-6k-1 Softening point 820+/-10 Strain point 516+/-10 Caloricity (20-100) 0.82kj x (kgxk)-1 Thermal coefficient 1.2wxmxk-1 Thermal shock resistance 180k Strengthening type 300k Identical temperature difference 100k Strengthening type 300 k Maximum working temperature short time(10h): 450 Chemical performance Water resistance iso719/din12111 hgb1/iso720 hga1 Acid resistance iso1776/din12116 1 Alkali resistance iso695/din52322 a2 Optical property Refractive index nd: 1.47384 Transmittance spectrum curve Electrical property Specific resistance lg 8.0+xcm at 250 Dielectric dissipation fraction tan = (1 megacycle at 20): 38x10-4 Dielectric constant s=4.7 Available thickness (mm): 1.50+/-0.20 4.00 +/-0.15 2.00+/-0.20 5.00+/-0.15 2.25+/-0.20 5.50+/-0.15 2.75+/-0.20 6.00 +/-0.15 3.0+/-0.20 6.50+/-0.20 3.30+/-0.20 7.50+/-0.30 3.80+/-0.15 8.00+/-0.30 We also do the follows to customers' requirements: Cutting Round corner Round edge Surface fine polishing Hole drilling Coating Surface printing and sand blasting Thermal bending Wooden crate package
Level Transmitter With wide expertise in this domain, we have come up with a wide array of Level Transmitter. To ensure the higher level of patron satisfaction, we provide these RF Level Transmitter in accordance to their given specifications. The product helps in easy measurement of liquids in open and huge tanks. Capacitance Level Transmitter A Capacitance Level Transmitter is formed between the probe and the vessel wall and the level of the measuring medium rises or falls, capacitance between the probe and vessel wall changes proportionately in a right manner. Our prestigious clients & customers can avail from us a wide range of Capacitance Level Transmitter from us. Description: Flowstar Series FECTX-100 are capacitance type level transmitters. The probe is based on properties of capacitor. Vessel wall & probe forms two electrodes. If vessel is of non conductive material, the probe will be double rod type. The distance between electrode & surface area of electrodes remain unchanged. The variable is the depth of the material being measured which represents the dielectric constant between two electrodes. Air & vacuum have relative dielectric constant as 1 & that of liquids, it is greater than 1. The capacitance of the capacitor the therefore depends on how much material lies between the probe & vessel wall i.e. whether the probe is covered with or free from material. The capacitor changes with change in level of the material & provides corresponding 4-20 mA DC continuous output Salient Features: 2 wire system Continuous 4-20 mA DC output Simple low cost & reliable Trouble free operation for conductive / non conductive Liquids, slurries Flameproof IP-65, P-65, IIA IIB, CMRI Certificate housing
Product Usage: Constant volume, configure standard solution. It can be used with straws and pipettes. Applicable industries: Isotope industry, heavy metal industry, semiconductor, new energy, new material, chemical pharmaceutical, nonferrous metal, precious metal... other products: PFA beaker, PFA reagent bottle, PFA drop bottle, PFA sample dissolution tank, PFA scrubber bottle, PFA drop bottle... FEP experimental utensils, PTFE experimental utensils, digestion apparatus, acid removal apparatus, acid purification system...