To trace hystersis curves on CRO using resistance, capacitance & inductance, instrument comprises of AC power supply 3-15V AC, output selectable using band switch, printed circuit diagram components connected behind the front panel, provision for connecting external inductance is given input & out connections brought out at sockets
1.Sharp stereo erect image over a wide field of view. 2.45 inclined and 360 rotational binocular head with locked-in eyepiece.The left ocular-tube with diopter adjustment +5dp,The interpupillary distance is between 55-75mm 3.Zoom objective 1x-4x 4.ZTX-E series supplied with pillar style stand, ZTX-E-W series supplied with arm curved style stand.ZTX-3E series trinocular head. 5.Electric apparatus has CE approval 6.Power supply 110V/60Hz or 220V/50Hz 7.Each set packed in styorfoam and in an inner box.Three sets in one carton 8.A wide range of optional accessories. Optional accessories: 1.Eyepiece WH5x(+22mm),WF10x(+23mm)WF15x(+13mm),WF20x(+10mm) 2.Auxiliary objective 0.5x,0.75x,1.5x,2x 3.Figure eyepiece:VD-TV,VD-PC 4.Darkfield stage,+95mm 5.White/black working plate,+95mm 6.Fluorescent bulb 5W 7.Halogen bulb 12V/10W/LED 8.Ring fluorescent lighting 8W & 10W 9.Wooden cabinet with lock and key /Aluminium case Each set packed in styorfoam and in an inner box.Three sets in one carton
Description: The test apparatus suitable for measuring the smoke emitted by wires and cables burning under specific conditions, such as horizontal combustion of some cables or optical cables, are used as a means of comparing different cables or optical cables or judging whether they meet specific requirements under flaming or flameless combustion conditions. . It meets the test standard of GB/T17651.1-2-19.98 "Determination of smoke density in combustion of cables and optical cables under specific conditions". Performance parameters: Optical measuring device: The light source and receiver should be placed in the middle position outside the sealing window on the opposite wall of the combustion chamber. Measurement range: 0-100%. That is, the optical device will be energized before the blank test. Calibration of transmittance: calibration with transmittance of 25%, 50% and 75%. Standard Fire Source: Standard Fire Source: 1.0L+0.01L Alcohol Plate; Ethanol: 90% +/- 1%; Methanol: 4% +/- 1%; water: 6% +/- 1%. Control system: adopt DETECION control procedure and ZWH 4500 acquisition control card. Operating interface: WINDOWSXP operating interface, DETECION control program, perfect security mechanism. During the test, the measurement results are displayed in real time and the perfect curve is plotted dynamically.