Wound drainage trocar
Code 81100: Non-adherent absorbent pad Features 1. Porous non-adherent film on both side with absorbent pad in the middle . 2. Absorbent pad absorbs drainage away from wound. 3. Non-adherent film will prevent absorbent pad sticking to wound Color: White Size: 5 x 5 cm (2''x2'') 7.5 x 7.5 cm (3''x3'') 10 x 10 cm (4''x4'')
Silicone Foam Wound Dressing the silicone dressing is a highly absorbent dressing made from hydrophilic polyurethane foam, ideally designed for heavily exuding wounds. The soft flexible foam absorbs large amount drainage, ensures patients comfort; the top backing film protect wounds against external bacterial. It's a disposable sterile product,it consists of silicone gel and polyurethane foam ,it has high liquid absorptive volume, isolates the wound penetrent liquid from the wound effectively,and reduce the possibility that the wound is infected.The product can form and keep a moist environment,promote wound healing ,and reduce the second damage when changing the dressing. Information for Use: 1)clean the wound with saline. 2)dry skin around the wound, select the appropriate specification ( crop the product if necessary ). Cover the wound completely. 3)tear the face mask, Stick to the wound. 4)use the second dressing to fix (island). Applications: Pressure ulcer Leg venous ulcer Diabetic foot ulcer First and second degree burns Skin grafts and donor site Post-operative and traumatic wounds Advantages: high absorptive volume of liquid isolate the wound penetrent liquid from wound, reduce the infection heal without scab,reduce the scar promote wound healing
Silicone Foam Wound Dressing the silicone dressing is a highly absorbent dressing made from hydrophilic polyurethane foam, ideally designed for heavily exuding wounds. The soft flexible foam absorbs large amount drainage, ensures patients comfort; the top backing film protect wounds against external bacterial. It's a disposable sterile product,it consists of silicone gel and polyurethane foam ,it has high liquid absorptive volume, isolates the wound penetrent liquid from the wound effectively,and reduce the possibility that the wound is infected.The product can form and keep a moist environment,promote wound healing ,and reduce the second damage when changing the dressing. Information for Use: 1)clean the wound with saline. 2)dry skin around the wound, select the appropriate specification ( crop the product if necessary ). Cover the wound completely. 3)tear the face mask, Stick to the wound. 4)use the second dressing to fix (island). Applications: Pressure ulcer Leg venous ulcer Diabetic foot ulcer First and second degree burns Skin grafts and donor site Post-operative and traumatic wounds Advantages: high absorptive volume of liquid isolate the wound penetrent liquid from wound, reduce the infection heal without scab,reduce the scar promote wound healing
Place of Origin: China Brand Name: OEM Model Number: 200ml/400ml Disinfecting Type: EOS Size: 200ml, 200ml/400ml Stock: NO Shelf Life: 3 years Material: Medical Grade PVC, Medical Grade PVC Quality Certification: CE, ISO 13485 Instrument classification: Class II Safety standard: / Usage: Single-use Packing: paper-plastic bag Style: with three spring OEM: Availbale Certificate: CE/ISO13485 Sterile: EO Gas Sterile Sample: Availble Shelf life: 5 YEAR
1.This product includes silicone reservoir, silicone flat drains or other silicone drains and stainless steel trocar. 2.Can use separately or using trocar for insertion and combining with silicone reservoir for fluids suction and collection. 3.Used for various surgeries. Size (ml): 100, 200, 400 Package: Plastic-paper pouch, sterile Pcs/ctn: 100ml: 96pcs/ctn (59*41*35cm) 200ml: 80pcs/ctn (59*41*35cm) 400ml: 40pcs/ctn (59*41*35cm)
Made of imported medical grade silicone This product includes 100cc/150cc/200cc/400cc Silicone Reservoir 7mm/10mm Flat drains or other round drains and stainless steel trocar Using Trocar for insertion and combining with silicone Reservoir for fluids suction and collection Used for various surgeries Latex-free EO Sterile Packing: individual blister packing, 20pcs/ctn
Negative Pressure Wound Drainage Machine Intelligence Product Model: MAX400-A1 Product Composition: Host, power cord, liquid collection bottle. The host is mainly composed of vacuum pump, control circuit, pressure sensor, CPU, control panel and display, chassis and built-in lithium battery. Application: Suitable for acute wounds, chronic diabetic wounds and wounds drainage of more exudate after surgery. Product Feature: 1. With ultra-low negative pressure design (-50mmHg to -450mmHg), which is continuously adjustable 2. With super-smart design and multiple operating mode which is more practical 3. With stable performance and long life which can operate more than 10,000 hours continuously. 4. The elaborate designed muffler system controls running noise of the device in a very low range (less than 45 dB), which does not affect the patientâ??s rest. 5. With microcomputer chip controlled, it has high accuracy and user-friendly operation interface. 6. Intelligent memory system can automatically record the parameters and modes in the last setup, free from repeatedly setting after each starting up. 7. LCD digital display makes it convenient for users to adjust and operate. 8. Multiple safe power supply solutions: a. AC and DC power supply is adopted, and the host is a full DC power supply, no danger of electric shock; b. Its build-in spare battery may still endure for four hours after a power failure, while it can last 8 hours in intermittent mode; c. A 12V 5A vehicle DC power supply can also be used to ensure the continuous treatment of patients with negative pressure drainage during transfer or going out. 9. Equipped with overflow alarm device, the unit will automatically stop in service and alarm when the dirty liquid reaches the warning line, to prevent the sewage from entering the host and to avoid secondary pollution and damage. 10. With the function of automatic gas-leak alarm, the unit will then spontaneously stop and alarm when the negative pressure value remains no change within 10 minutes after the operation. 11. Multiple safety protections: air-leak alarm, automatic overheat prevention, overflow prevention, etc. Product Property: Adjusting scope: 10mmHg; Negative pressure range: -50mmHg-450mmHg; Pressure display error: + 0.2%; Suction flow: 1.5L / min-8.0L / min; Noise: not more than 45Db; External power supply: 12V 5A DC switch power supply(medically certified), the host, DC powered, has no risk of electric shock; Operation status: continuous and intermittent Contraindication: Debridement undone or wound with the necrotic eschar; Wound with tumor tissue; Sinus connected with the organs; Wound with great vessels or organs exposed.