Product Name:Cummins GeneratorStandby Output:198kVA
Prime Output:180kVAFrequency:50Hz
Rate Voltage:400 / 230VAlternator Brand:Stamford
Lternator Model:UCI 274 GEngine Brand:Cummins
Engine Model:6CTA8.3G2Starting Voltage:24 V
Rate Output:181kVA
EAC 825 Engine Engine Model : KTA38-G2 Stand By kVA: 825 Stand By kW : 660 Prime kVA: 750 Prime kW : 600 Rated Current : 1080 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model KTA38-G2 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 731 / 980 Prime Power Hp 664 / 890 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 167 Lt %75 LOAD 128 Lt %50 LOAD 90 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9250 Weight (Open) Kg 8100 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 790 Engine: CUMMNS Engine Model : KTA38-G1 Stand By kVA: 790 Stand By kW : 632 Prime kVA: 718 Prime kW : 574 Rated Current : 1033 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTA38-G1 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 701 / 953 Prime Power Hp 634 / 862 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 158 Lt %75 LOAD 122 Lt %50 LOAD 86 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9200 Weight (Open) Kg 8050 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 750 Engine: CUMM NS Engine Model : QSK19-G11 Stand By kVA: 740 Stand By kW : 592 Prime kVA: 672 Prime kW : 538 Rated Current : 968 Engine CUMM NS heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional Thermal magnetic CB (for automatic models) Super Silent Canopy Mobile Generator Sets Automatic fuel filling system Synchronization panel 3 Pole and 4 Pole ATS (Automatic Transfer Switch) Fuel Heater, Oil Heater External fuel tank and automatic fuel filling system Fuel - water separator filter Remote monitoring and control system Engine CUMM NS Engine Model QSK19-G11 Number of Cylinders 6 - Inline Injection System Direct Compression Ratio 15.9 : 1 Bore 159 Strok 159 Displacement lt 19 Air Intake Turbo Aftercooler Speed (RPM) 1500 Oil Capacity lt 80 Standby Power kW / Hp 667 / 907 Prime Power kW / Hp 606 / 827 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity lt 42 Fuel Consumption (lt / h) lt Full Load 135 lt %75 LOAD 103 lt %50 LOAD 69,5 Frequency Hz 50 Power kVA 740 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP21 - IP23 Power Factor 0,8 Weight (Silent) Kg 5750 Weight (Open) Kg 4900 Width (Silent) mm 1900 Length (Silent) mm 4800 Height (Silent) mm 2700 Fuel Tank Capacity lt 1350 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 690 Engine: CUMM NS Engine Model : KTAA19-G6A Stand By kVA: 690 Stand By kW : 552 Prime kVA: 630 Prime kW : 505 Rated Current : 910 Engine - CUMM NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM NS Engine Model KTAA19-G6A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.0:1 Bore 159 Strok 159 Displacement L 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity L 38 Standby Power kw / Hp 610 / 825 Prime Power kw / Hp 554 / 750 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 75 Fuel Consumption (lt / h) L Full Load 148,3 L %75 LOAD 112,7 L %50 LOAD 76,4 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5200 Weight (Open) Kg 4530 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity L 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 650 Engine: CUMMNS Engine Model : KTAA19-G6 Stand By kVA: 650 Stand By kW : 520 Prime kVA: 590 Prime kW : 472 Rated Current : 849 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTAA19-G6 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.0:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 38 Standby Power kw / Hp 570 / 770 Prime Power Hp 518 / 700 Fuel Type Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 75 Fuel Consumption (lt / h) Lt Full Load 140 Lt %75 LOAD 104,9 Lt %50 LOAD 74,5 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5190 Weight (Open) Kg 4510 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity Lt 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 550 Engine: CUMMNS Engine Model : KTA19-G3A Stand By kVA: 550 Stand By kW : 440 Prime kVA: 500 Prime kW : 400 Rated Current : 720 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTA19-G3A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.9:1 Bore 159 Strok 159 Displacement L 19 Air Intake Turbocharged & Intercooled Speed (RPM) 1500 Oil Capacity L 38 Standby Power kw / Hp 504 / 675 Prime Power kw / Hp 448 / 600 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 75 Fuel Consumption (lt / h) L Full Load 107 L %75 LOAD 82,3 L %50 LOAD 56,4 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5085 Weight (Open) Kg 4410 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity L 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 220 Engine: CUMM NS Engine Model : 6CTAA8.3-G2 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine - CUMM NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model 6CTAA8.3-G2 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 18.0:1 Bore 114 Strok 135 Displacement L 8,3 Air Intake Turbocharged Air Aftercooled Speed (RPM) 1500 Oil Capacity L 23,8 Standby Power kw / Hp 203 / 272 Prime Power kw / Hp 183 / 245 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 12,3 Fuel Consumption (lt / h) L Full Load 45 L %75 LOAD 34 L %50 LOAD 23 Frequency Hz Power kVA 220 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1 Insulation Class H Protection Standard IP22 - IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity L 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
4BT3.9-C100 75/2400 330/1500 Turbocharged 4BT3.9-C105 77/2800 330/1500 Turbocharged 4BTA3.9-C110 82/2200 460/1400 TurbochargedáAftercooled 4BTA3.9-C125 93/2200 475/1500 TurbochargedáAftercooled 4BTA3.9-C130 97/2500 475/1500 TurbochargedáAftercooled 6BT5.9-C115 85/2000 430/1500 Turbocharged 6BT5.9-C120 87/2200 430/1500 Turbocharged 6BT5.9-C125 92/2400 425/1500 Turbocharged 6BT5.9-C130 97/2200 560/1500 Turbocharged 6BT5.9-C135 100/2000 570/1500 Turbocharged 6BT5.9-C135 100/1900 590/1500 Turbocharged 6BT5.9-C135 100/2200 560/1500 Turbocharged 6BT5.9-C145 106/2100 580/1500 Turbocharged 6BT5.9-C150 110/2300 560/1500 Turbocharged 6BT5.9-C150 112/2500 565/1500 Turbocharged 6BT5.9-C150 110/2200 580/1500 Turbocharged 6BT5.9-C150 112/2400 580/1500 Turbocharged 6BTA5.9-C150 112/1800 630/1400 TurbochargedáAftercooled 6BTA5.9-C155 114/2000 630/1500 TurbochargedáAftercooled 6BTA5.9-C170 125/2300 630/1400 TurbochargedáAftercooled 6BTA5.9-C175 128/2100 680/1500 TurbochargedáAftercooled 6BTA5.9-C180 132/2200 750/1300 TurbochargedáAftercooled 6BTA5.9-C180 132/2500 630/1500 TurbochargedáAftercooled 6CTA8.3-C145 108/1900 674/1400 TurbochargedáAftercooled 6CTA8.3-C175 128/1850 820/1100 TurbochargedáAftercooled 6CTA8.3-C180 134/2000 837/1400 TurbochargedáAftercooled 6CTA8.3-C195 145/1900 820/1500 TurbochargedáAftercooled 6CTA8.3-C215 160/2200 908/1500 TurbochargedáAftercooled 6CTA8.3-C215H 160/2200 908/1500 TurbochargedáAftercooled 6CTA8.3-C230 172/2200 1000/1500 TurbochargedáAftercooled 6CTA8.3-C240 179/2200 1028/1500 TurbochargedáAftercooled 6LTAA8.9-C325 239/2200 1230/1400 TurbochargedáAftercooled .
ENGINE SERIES ENGINE MODEL SO NUMBLE RATED POWER MAX POWER (HP/RPM) (HP/RPM) Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M270 SO13011 245/1744 270/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M300 SO13012 272/1744 300/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M240 SO13058 218/1744 240/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M270 SO13386 245/1744 270/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M300 SO13387 272/1744 300/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M240 SO13388 218/1744 240/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M300 SO13416 272/1744 300/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M SO13414 250/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M SO13415 280/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M250 SO13417 227/1744 250/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M280 SO13418 255/1744 280/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M300 SO13419 272/1744 300/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M SO13517 255/1744 280/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M SO13518 272/1744 300/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M200 SO13421 220/1744 220/1800 Cummins NT855 marine diesel engine for marine propulsion NT855-M NT855-M200 SO13460 200/1744 220/1800.