Portable Near Infrared Analyze
FPIs SupNIR-2700 series near infrared analyzer is designed to meet customersdemand of accurate and rapid analysis of grain, oil and feed for quality control and pricing. It requires minimal operator training and instrument maintenance. Analysis takes less than a minute and no chemicals are required. Operation is very simple, just pour the sample into the dish, place under the instrument, and automatic analysis will be done within a click.
The user-friendly RIMP software combines instrument control, data analysis and modeling in one. It is connected to the dynamic link libraries, thus ideal for data output and office automation. Report forms can be customized according to customers demand. With the existing analysis model, the analyzer performs accurate analysis for quality control of raw material and finished products in solid grains, pellets, pastes and powders.
Supplier: California almonds, pistachios, saudi arabian dates, ajwa, khidari, medjool, cashew nuts w240, cashew kernels w320, uht milk, oats, rolled oats, soybean meal, soybean oil, ghee, soya lecithin liquid, processed milk goods, skincare products, branded fmcg goods, confectionery, soft drinks, food items, european cosmetics, korean cosmetics, beauty face masks, 1121 sella basmati rice, s30 sugar, icumsa 45, 5% parboiled rice, lentils, soya chunks
Services: Sourcing agent, warehousing solutions, oem manufacturing
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Vasthis handheld Flue gas analyzer,Model-VE5400 offers the efficiency of complete combustion optimisation all the way to comprehensive measurement and customer data management.Our Portable flue gas analyzers cover the entire measurement and documentation requirement in process and flue gas testing with instant reading. Vasthiâ??s VEA800 series is an ideal analyzer that measures 5 gases with 4 sensors. User friendly gases selection is implemented in this analyzer. This Portable Flue Gas Analyzer consists unique features.It has in-built crystal-clear touch display which enables user to view concentration values of flue gases and Bluetooth/Wi-Fi connectivity facilities.Using these facilities,Users can download the stored data as well as print it with any printer using Bluetooth / Wi-Fi User can compare daily data with charts & graphs to optimize and increase the combustion efficiency. Measuring Gases SO2,NO,CO2,NO2,Flue Gas Temperature & Temperature combustion air VASTHI will give the gases as per customer required..
Quality standard: With FDA and CE certification EN Standard 266001-1:2006 +A11:2006 +A1:2003 +A12:2004 EN550111:2016+A1:2017 EN60601-1-2:2017 EN61000- 3-2:2014 EN61000- 3-3:2013 Transport & Storage Temperature-25 -55 Relative Temperature 90% Measuring time 0.5Sec Measurement accuracy + 0.1 Accuracy/Body Temperature Mode : Within range 32.0 -42.9 Out of range : 32.0-42.9 ±0.3 Measuring Range Body Temperature Mode : 32.0-42.9 Measuring Distance : 1-3cm Operating Temperature : 10.0-40.0 Operating Humidity : 85% Power Supply ; DC3V(2PC*AAA battery Automatic Power : Off 10Sec Packing Size : 105X45X160mm(Length* Width * Height) Product Weight : 90g (Battery not included)
Applications: Coal or biomass gasification, plasma pyrolysis & gasification, coal chemical process, heating treatment, steel making process such as blast furnace, Converter, Coking, Direct Iron Ore Smelting Reduction Process. Specifications: Measurement: CO, CO2, CH4, H2, O2, CnHm, N2 & calorific value Technology: CO, CO2, CH4, CnHm : NDIR H2: TCD O2: ECD Rang: CO: 0-30% CO2: 0-25% CH4: 0-10% H2: 0-30% O2: 0-25% CnHm: 0-5% ï¼?Measurement range can be customized by the requirementï¼? Resolution: CO, CO2, CH4, H2, O2, CnHm: 0.01% Precision: CO, CO2, CH4, CnHm: â?¤ 2%FS H2, O2: â?¤ 3%FS Repeatability: CO, CO2, CH4, H2, O2, CnHm: â?¤1% Flow rate: 0.7-1.2L/min Inlet pressure: 2kPa-50kPa Sampling gas condition: no dust, no water vapor, no tar Response time: T90ï¼?10sï¼?NDIRï¼? Signal output: RS-232 digital output Power supply: Built-in rechargeable lithium battery Features: 1ã?�Adopt international advanced NDIR and TCD gas analysis technology. 2ã?�Can measure the concentration of CO ,CO2 ,CH4 ,H2 ,O2 ,CnHm simultaneously. 3ã?�Automatically calculated heating value, unit can be switched between Kcal/m³ and MJ/m³. 4ã?�CnHm gas has no interference with CH4 measuring result. 5ã?�H2 reading is compensated for the interference effects of the CO ,CO2 ,CH4 measured. 6ã?�Built-in sampling pump. 7ã?�Up to 1500 sets of data storage 8ã?�RS-232 digital output interface. 9. LCD 320 x 240 display with back-lit function Working environment Work temperature: 0-50â?? Relative humidity: â?¤95% non-condensing Ambient pressure: 86-108kPa Dimensions 520mm(L)*430mm(W)*320mm(H) Net weight: about 5kg
KD-MINI01 POWER:1000w SIZE :1200*700*1150mm 1ã?�Canadian hemlock 2ã?�Digital control panel 3ã?�100%pure ceramic heater 4ã?�Temperature 18-60 Health-care;fat reduce;body beauty;activate the body cell,enhance immune system 11) Approved "CE" and "RoHS "certificate MoQ : 1 set delivery time : 10 days for sample
Near infrared heater 380x140x110, 2kg, wall-type, stand type
Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points. ã??Main technical parametersã?? exhaust gas analyzer measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm) O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm) oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm oil temperatureï¼?0.1 speedï¼?1rpm Repetitive error â?¤±2% Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h Distance drift No more than shown value error allowed (4 hours) Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼? CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼? HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼? O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼? NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼? environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼? temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter) Preheating time 10min Weight Measurement unitï¼?10Kg vice machineï¼?3Kg Volume Measurement unitï¼?610 * 500 * 330mm Auxiliary machine:500 * 350 * 330mm Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm; Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m; Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine. Display mode LCD large screen liquid crystal display major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection. 2)With idle speed, double idle test function; 3)Auto calculation shows that the excess air coefficient isï¼? 4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼? 5)Matching speed and temperature measurement functionï¼?
Its simple automatic operation, continuous measurement & digital display of purity concentration makes it a valuable aid for on-site instant analysis & follow up action. Its data logging & computer interface features can be used for further detailed analysis in the laboratory.The HNL Portable Model GA - 154 with digital read out and alarms is a direct reading compact Portable Gas Purity Analyzer, designed to serve the demanding field requirements of various gases Producing and using Industry. It is designed to replace the cumbersome and time consuming Or set apparatus and provide quick and accurate reading of gas Purity. It offers the user a distinct advantage in terms of economy, dependability maintenance and ease of operation. The instrument incorporate TCD / INFRARED as a transducer. It has adjustable visual and audible alarms with Automatic Zero Calibration Feature