Y511-A Turbidity Sensor Description
Automatic cleaning turbidity sensor is complied with ISO 7027 Turbidity Standard. The turbidity sensor can be deployed in-situ and provide very stable data over long period of usage, which helps to ensure the quality of your measurements.
Y511-A Turbidity Sensor Typical Applications
Water quality monitoring, waste water testing, process water and aquaculture monitoring.
Y511-A Turbidity Sensor Features
* 0.1~1000 NTU
* Accuracy
Y511-A Turbidity Sensor Description Automatic cleaning turbidity sensor is complied with ISO 7027 Turbidity Standard. The turbidity sensor can be deployed in-situ and provide very stable data over long period of usage, which helps to ensure the quality of your measurements. Y511-A Turbidity Sensor Typical Applications Water quality monitoring, waste water testing, process water and aquaculture monitoring. Y511-A Turbidity Sensor Features * 0.1~1000 NTU * Accuracy -
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
MB7589 SCXL-MaxSonar-WRMT Self Cleaning Precision Ultrasonic Rangefinder Product Description The weather resistant SCXL-MaxSonar-WR selfâ??cleaning sensor is a rugged ultrasonic sensor component module. This outdoor sensor provides very short to long distance detection and ranging in a compact, robust PVC housing. The ultrasonic sensor meets the IP67 water intrusion standard and matches standard electrical 3/4-inch PVC pipe fittings. MB7589 Features and Benefits * Factory calibrated beam width * Low operating voltages from 2.7V to 5.5V * All range outputs are active simultaneously * Superior clutter rejection MB7589 Applications and Uses * Bin Level Measurement * Tank Level Measurement z
NTU Nephelometric Turbidity & Temperature Sensor Optical technology : The measure principle is based on IR nephelometry / 880 nm (ISO 7027). The sensor can be calibrated with a formazine standard solution. The NTU sensor integrates a low-cost optical technology, with a very few maintenance and no consumables. NTU Nephelometric Turbidity & Temperature Sensor Digitally optimised measurement technology * IR optical sensor with optical fibre * Range: 0-4000 NTU or 0-4500 mg/L * Digital sensor: Modbus RS-485 * ISO 7027 compliant * Robust and waterproof NTU Nephelometric Turbidity & Temperature Sensor Applications * Industrial effluent treatment * Urban waste water treatment * Surface water monitoring * Drinking water * Sanitation network NTU Nephelometric Turbidity & Temperature Sensor Specifications * Measurement principle: Diffusion IR at 90' * Range: 0-4000 NTU or 0-4500 mg/L * Resolution: 0,01 to 1 NTU - mg/L * Accuracy: < 5% of the reading * Temperature compensation: via CTN * Operating temperature: -10'C to + 60'C * Signal interface: Modbus RS-485 (standard) and SDI-12 (option) * Sensor power-supply: 5 to 12 volts -
WQ730 Turbidity Sensor Description WQ730 Turbidity Sensor is a highly accurate submersible instrument for in-situ environmental or process monitoring. Applications for the WQ730 include: water quality testing and management, river monitoring, stream measurement, reservoir water quality testing, groundwater testing, water and wastewater treatment, and effluent and industrial control. WQ730 Submersible Water Quality Sensor Turbidity Sensor Features * 4-20 mA output * Marine grade cable with strain relief * In-situ turbidity measurement * Simple and convenient to use * Rugged stainless steel and Delrin sensor housing WQ730 Turbidity Sensor Specifications * Range: 0-50 NTU and 0-1000 NTU * Accuracy: +/- 1% of full scale * Meter Resolution: 12 bit * Output: 4-20mA * Operating Voltage: 10-36 VDC at 40 MS * Current Draw: 30 mA plus sensor output * Warm Up Time: 5 seconds minimum * Operating Temperature: 14 to 122'F (-10 to +50'C) * Maximum Pressure: 30 psi
Y504-a dissolved oxygen sensor description The sensor is based on optical fluorescence lifetime quenching technique. Its technical procedure meets astm d888-09 standard for optical sensing of dissolved oxygen. This online sensor is developed to integrate with yosemite wireless monitoring system. Its rugged design and large measurement range make it ideal for sampling, flow cell, ground water and waste water measurements. Y504-a dissolved oxygen sensor applications Fish farmer, waste water plant, river, stream, and ocean monitoring Y504-a dissolved oxygen sensor feature , 0-20mg/l or 0-200% saturation , 0~50'c; ip68 rating , membraneless, no electrodes design , no oxygen consumption , flow independent , automatic temperature compensation , no h2s interference , low drift, fast response, and more accurate , low maintenance, low operating cost , easy sensor cap replacement , rs-485; modbus protocol compatible Y504-a dissolved oxygen sensor technical specifications , range, : 0-20mg/l or 0-200% saturation, , response time: 10 sec , housing ip rating: ip68, , accuracy: 1%, , drift:
Y504-A Dissolved Oxygen Sensor Description The sensor is based on optical fluorescence lifetime quenching technique. Its technical procedure meets ASTM D888-09 standard for optical sensing of dissolved oxygen. This online sensor is developed to integrate with Yosemite wireless monitoring system. Its rugged design and large measurement range make it ideal for sampling, flow cell, ground water and waste water measurements. Y504-A Dissolved Oxygen Sensor Applications Fish farmer, waste water plant, river, stream, and ocean monitoring Y504-A Dissolved Oxygen Sensor Feature * 0-20mg/L or 0-200% Saturation * 0~50 'C; IP68 rating * Membraneless, no electrodes design * No oxygen consumption * Flow Independent * Automatic temperature compensation * No H2S Interference * Low Drift, fast response, and more accurate * Low Maintenance, low operating cost * Easy sensor cap replacement * RS-485; MODBUS protocol compatible Y504-A Dissolved Oxygen Sensor Technical Specifications * Range: 0-20mg/L or 0-200% Saturation * Response Time: 10 sec * Housing IP Rating: IP68 * Accuracy: 1% * Drift: -
We are proud to say that for the first time in India, we are launching Battery temperature sensors for commercial purposes. The specialty of the sensor is that we can measure the in situ temperature. So far, the widely popular technique is to monitor the battery temperature by placing a sensor adjacent to it. As expected, the accuracy of this method is not up to the mark. Now with the advent of Arcotherm's unique sensors, more accurate values can be obtained. Currently, we are exporting these to the European market.