Application
Oxygen permeability tester is based on the coulometric sensor method and available for the otr test of flexible films, sheeting and packages. It can test 3 specimens in one operation with independent results.
Films:
Plastic films, aluminum foil, aluminized films, plastic composite films, paper-plastic composite films, coextruded films, aluminum foil composite films and many others.
Packages:
Plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.G. Red wine bottles, blister, various plastic bottles, coke bottles, peanut oil packages, tetra pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups
OX2/231 is based on the equal pressure method, and professional applicable to the determination of oxygen transmission rate of plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.
Supplier: Pressure method gas permeability tester, coulometric sensor method oxygen permeability tester, water vapor permeability tester(cup, electrolytic and infrared sensor method), auto tensile tester, thickness tester(0.1um)
Application It is used for evaluating the torque retention of continuous thread closures on containers, and measuring the torque required to tighten or unscrew the closure from a container. Features 1. Our own patent technology. 2. Touch screen operation. 3. Real color tft lcd display. 4. Test results and torque curve display. 5. High-accuracy torque sensor inside. 6. Peak test, continuous test, preset value test 7. Clockwise, un-clockwise test. 8. Result with multiple units. 9. Micro-printer prints mini-report. 10. Overload warning. 11. Low power consumption. 12. Rs232 communication port. 13. Professional computer software support.(optional)
Application Auto tensile tester applies to plastic films, sheets, rubber, laminated films, extrusion films, foils, paper, medical patches, release paper, non-woven fabrics etc testing of various items, such as tensile, break force, elastic modulus, elongation, seal strength, t-style peeling strength, 90 peeling strength, 180 peeling strength, widely used in food & pharmaceutical industries, quality inspection departments as well as research and development institutions.
Applies to best parameters determination of heat sealability of various kinds of film. Heat sealability of film depends on temperature, pressure and heat time and the hsl-6001 heat seal tester is widely used in food and pharmaceutical packaging industries. Features 1: our own patent technology 2: embedded system control 3: touch screen operation, easy to operate 4: tft lcd display, ui flattening design 5: dual heat jaws, temperature controlled independently 6: micro-printer prints mini-report 7: pressure easy to adjust, heat temperature and time touch screen input. 8: emergency stop button, safety design to prevent burns 9: over temperature protection, over pressure protection 10: silence working 11: db9 rs232 communication port. 12: dsm system is optional(laboratory management information system), easy to manage and share test data.
Supplier: Dental laser equipments, liposuction systems, skin tester, oxygen system, long pulse for hair removal, E-light, PDT skin care system, diode lasers, cellulite reduction systems, RF systems, CO2 lasers, ND-YAG lasers, IPL series
Radio frequency diathermy Multi function with dual radio frequency system Biological effects 1. Increase of arterial circulation - vasodilatation -, giving rise to increased oxygenation and a decreased acidity of the tissues. 2. Increase of venous drainage with greater re-absorption of catabolites and decreasing of the edema in areas with inflammatory processes. 3. Increase of the permeability of the cellular membrane, allowing better transfer of metabolites through it. 4. Speeding up of cicatrization of wounds. 5. Stimulation of the immune system and decrease of free radicals. The therma-g plus method is currently being applied in most medical specialities, particularly in: Traumatology and rehabilitation. Rheumatology. Sports medicine Neurosurgery and neurology. Dermatology. Pain clinics. Oncology : radiotherapy and chemotherapy Specification 1. Model name : therma-gplus 2. Main voltage : ac220v, 60hz 3. Power consumption : 500w 4. Rf output frequency : 0.3mhz, 0.5mhz 5. Treatment time : 0 ~ 60 min 6. Treatment mode : electrode type, pad type 7. Safety device : zero start 8. Protective system : class 2, bf type 9. Weight : 30kg 10. Dimension : 370(w) 450(d) 1000(h)
Multi-layer cell factory is the adherent cells' ideal choice for industrial mass production, laboratory operations, and large-scale cell cultures. The cell factory is a bioreactor system used for high-density cell culture in an adherent culture. Adherent culture is a technique used to culture cells that require a surface to grow on, such as stem cells and many types of animal cells. The cell factory consists of multiple layers of stacked polystyrene plates, each with a surface area of up to several thousand square centimeters. The plates are coated with a layer of extracellular matrix protein to support cell adhesion and growth. The cell factory is designed to optimize cell growth and productivity by providing a controlled environment for the cells. The system is equipped with a quick-switching sealing lid that can switch between airtight and air-permeable states to regulate the dissolved oxygen and exhaust gas levels during different stages of cell growth. The double large mouth design of the cell factory allows for easy liquid filling and harvesting, and the system is designed to minimize air bubble formation to facilitate gas exchange.