OXY-LC Oxygen Sensor Interface Board Description
The OXY-LC Oxygen Sensor Interface Electronics provides the necessary electronics to power and control SST range of zirconium dioxide (ZrO2) sensors.
The OXY-LC Oxygen Sensor offers various user configurable output variants RS485, PWM, 0-10Vdc and 4-20mA. The RS485 Modbus RTU Protocol offers various benefits over other output types but most importantly it allows complete control of the sensor operation and access to all available information including sensor diagnostics, barometric pressure and pressure sensor temperature.
The adaptive software filtering which enables it to provide a fast response coupled with a stable oxygen output. In addition to this, the OXY-LC Oxygen sensor interface electronics offers a high accuracy linear output for all of our zirconium dioxide oxygen sensors.
The built in pressure sensor allows for barometric pressure compensation and the interface mounted screw terminals offers easy wiring with reverse voltage and transient overvoltage.
OXY-LC Oxygen Sensor Interface Board FEATURES
* Provides the electronics necessary to power and control SST range of zirconium dioxide (ZrO2 ) sensors
* Built in pressure sensor for barometric pressure compensation
* Interface mounted screw terminals for easy wiring with reverse voltage and transient overvoltage
OXY-LC Oxygen Sensor Interface Board BENEFITS
* Adaptive software filtering provides a fast sensor response coupled with a stable oxygen output
* High accuracy linear outpu
t
LED light.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Powerï¼? 900W LED Qtyï¼? 72pcs 5W LED & 6pcs 90W COB Voltage ï¼? AC85-265V Work frequencyï¼? 50/60Hz Lumen ï¼? >15400Lm Dimmensionï¼? 660X385X118mm N.W ï¼? 11.4kg Coverage ï¼? 1.0Ã?1.2 m Warranty ï¼? 50000 hours
Power 900W LED Qty 72pcs 5W LED & 6pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen >15400Lm Dimmension 660X385X118mm N.W 11.4kg Coverage 1.0 1.2 m Warranty 50000 hours
Power 1200W LED Qty 96pcs 5W LED & 8pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen 21050Lm Dimmension 848X385 X118mm N.W 14.8kg Coverage 1.5 X1.0 m Warranty 50000 hours
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
O2I-Flex Oxygen Sensor Interface Board FEATURES * Provides the electronics necessary to power and control SST's range of zirconium dioxide (ZrO2 ) sensors * Externally triggered automatic or manual calibration. Calibration can also be initiated via an on-board push button * Power and sensor operating LEDs * Removable polarised screw terminals for easy wiring BENEFITS * Adaptive software filtering provides a fast sensor response coupled with a stable oxygen output * High accuracy linear output * Can be calibrated in fresh air (20.7% O2 ) or in any other known O2 concentration TECHNICAL SPECIFICATIONS Supply voltage 24V DC ± 10% Supply current 600mA max. at 24V DC Digital output RS232 Analogue output 4 ~ 20mA; load 100 ~ 600Ω or 0 ~ 10V DC ; load 10kΩ min Temperature limits Storage: -10'C to +70'C Operating: -10'C to +70'C Oxygen pressure limits 1 ~ 1000mbar OUTPUT VALUES Oxygen range (analogue output) 0.1 ~ 25% O2 or 0.1 ~ 100% O2 Oxygen range (RS232 output) 0.1 ~ 100% O2 Accuracy after calibration 1% O2 Repeatability after calibration 0.5% O2 Output resolution: 0-10V DC : 0.01V 4-20mA: 0.01mA RS232: 0.01% O2 Response time (step 10-90%) Fast response sensor connected: < 4s Standard response sensor connected: < 15s Initial warm up time (till stable output) 5 ~ 10mins Output inactive start up delay (heater warm up) 60s
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
Distance Measurement Interface Board HG-DMSI-02 Distance Measure Sensor Interface Board Features * Size : 80 x 80 mm * Channel : Connect up to 8 Ultrasonic Sensors (HG-B40A, HG-B40C Conly) * Power : DC 12V(DC Jack connector 1ea, 2pin connector 1ea), DC 5V(2pin connector 1ea) * Output : RS232(9-pin DSUB 1, 3-pin connector 1), UART(3-pin connector 1) HG-DMSI-02 Distance Measure Sensor Interface Board Communication Setting * Default Baudrate : 57600 bps * (LED ON is showing current Baudrate ) 1: 9600, 2:19200, 3:38400, 4:57600 * Data bit : 8 bit * Stop bit : 1 bit * Parity bit : None * Hardware Flow control : None