Please click here to check who's online and chat with them.

Toroidal Transformer Winding Machine

Supplier From China
Aug-28-17

Specifications:
1adopts the iternational most advanced plc control technology.
2.It can perform the forward and backward winding and counting operation,
Power failure protection, wire disconnection protection, stop brake, setup
Of winding position, location and fault prompt.
3.It can set the procedures and display the operation state through the
Touch panel.
4.It,s english interface can properly display the wire diameter, rotatin
Speed, number of turns and nunber of layers.

5.Its main sharft control adopts the frequencyconversion stepless speed
Adjustment, with the characteristics of short driving chain, large driving
Torque, wide speed adjustment range, low noise.

6.It,s speed control has two modes, automatic setup and foot switch speed
Adjustment.

7.It,s wire arranging operation is finished by the stepping motor and
Highprecision ballspline, the control precision can reach as high as 0.001mm.

8.The counting operation adopts the lighgrid rotary encoder, the output
Rotation speed and angle signal are traced with the data.

9.The tension controller employs the west germany damping device, so as to
The wire easy disconnection or coul loosing and dropping for the gension
Unbalance and easy fluctuation.

Features:
Simple operation
Low noisy
Reliable system operation
Complete function
Wide application range
Compact structure
High winding precision
Long life service

Yr260j/360j can adjust the processing range with the iron core and framework size.
Through changing the different clapm.It can wind the coils of various
Casting pts, it's necessary winding equipment for producin gthe pts with
Rshaped enclosed iron core, also the preferred electric engineering
Equipment in the pt industy.


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Toroidal Transformer Winding Machine

Jun-04-13
 
Used for television, electrical control system, charger inverter, electric apparatus, audio equipment etc.
Oct-23-13
 
1.Operating temperature range:-20 to +45
2.Storage temperature:-40 to 70
3.Switching frequency:1khz to 200khz
4.Withstanding voltage:1500/3750vac for 1 minute between primary and secondary
5.Insulation resistance:500vdc 100m¦¸ miin. Between primary&secondary.


As per customer's requirment
Dec-27-11

Transformer

$180.00
MOQ: Not Specified
 
Used in current transformer & power transformer, also used in servo voltage stabilizer & variable auto transformer - dimmer or variac.

As per customer requirement.
Mar-29-14
 
1. Introduction:
Our wound cores are widely used in distribution transformers, especially for s13 type energy-saving transformers in china; we could provide our customers with single phase wound cores, three phase wound cores; the capacity range from 10kva to 2500kva; due to its particular technology craft, its performance is better than traditional stacked cores, especially for pole-mounted single phase transformer.
2.Manufacturing requirements:
Tolerance: see demonstrated graphic; the specified requirements should be coincide with customers drawings;


Standard export package
Mar-29-14
 
1. Introduction:
Our wound cores are widely used in distribution transformers, especially for s13 type energy-saving transformers in china; we could provide our customers with single phase wound cores, three phase wound cores; the capacity range from 10kva to 2500kva; due to its particular technology craft, its performance is better than traditional stacked cores, especially for pole-mounted single phase transformer.
2.Manufacturing requirements:
Tolerance: see demonstrated graphic; the specified requirements should be coincide with customers drawings;
Material: we could choose nippon steel, baosteel, wisco and other steel plants products to meet customers core loss requirements; in order to make sure we choose the right material, we would like our customers to provide us with detailed drawings including necessary technical parameters.


Standard export package
Feb-20-20
 
Size: 0501, 0502, 0701
L: 0.18mH~21mH
Dec-25-20
Buyer From Ahmedabad, Gujarat, India
Jan-03-12
Supplier From Johor Bahru, Johor, Malaysia
Sep-01-22
 
Product description

Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard



technical parameter

1. Temperature:

2. Relative humidity

3. Rated Primary Current:5-5000A 5A,1A

4.Rated secondary current:5 1A

5 Accuracy Class 0.05S

6. Allow long-term work under the rated current; More than120A across the core.



Precautions:

1. The current of standard CT and tested CT must be the same in CT calibration.

2. Follow the given wiring diagram strictly.

3. Test whether the load box is accurate or not before calibrating the transformer.

4. Forbid secondary winding opening during the calibration.

5. Select demagnetization before calibration.The wiring diagram is shown in figure 5.

Short out the secondary winding before cutting off the power when the demagnetization is finished.

6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.

Verification Status