Please click here to check who's online and chat with them.

350Kva Diesel Generator Set With Cummins Engine

Supplier From China
Jun-12-17

350kva, 50hz, 3phase, 220/380v, standby power, silent type.
Cummins engine nta855-g1b with stamford alternator, deepsea controller dse7320, delixi circuit breaker


Brilliant power, the headquaters is in china and western factory in spain, uk, is a market-oriented enterprise based on 10 years experience in the field of generator set, lighting tower and related accessories , whose power range from 8kva to 4000kva. As a new generation in the power generation industry, we fully supply generator set, lighting tower to our clients in accordance with market /customer demand for a variety of applications, such as residential, commercial, industrial, rental purposes.
In order to supply reliable and excellent performance , brilliant adopts renowned engine from all over the world, covering deutz, perkins, cummins, doosan, mitsubishi, yanmar as well as trusted chinese engine. In consideration of stable voltage output, top-class alternator is our prior option, including leroysomer, stamford, meccalte etc, to be cost-effective , domestic alternator with reliable performance is available too.
On the basis of market segmentation and product orientation, we are not only supply generator set, lighting tower to the market, but also focus on differential applications , which follow the idea of selling products as a consulter not just a manufacturer.

Price and Minimum Quantity

Price: $21000 - $22000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: 350Kva Diesel Generator Set With Cummins Engine

GOLD Member
Oct-18-24
Supplier From Busan, South Korea (Republic Of Korea)
We have a stock of quality, low-life generators from the military
ï?¬ CAT 3408 400kW
ï?¬ CAT C-16 500kW
ï?¬ CAT 3406 350kW (House type)
ï?¬ Cummins VTA-28G5 500kW
ï?¬ Cummins LTA-10 250kW (House Type)
ï?¬ Cummins LTA-10 250kW
ï?¬ Cummins NT85-G3 350kW
ï?¬ Cummins NT85-G3 350kW (House type)
ï?¬ Cummins NT85-G2 300kW
Please study if it is suitable for your market.
GOLD Member
Feb-21-25
Supplier From Busan, South Korea (Republic Of Korea)
We have 4sets of used Detroit generators that were used as emergency power sources (Standby only) at a municipal water drainage plant in Korea. Please review the attached documents and assess
ENGINE SPECIFICATION
ENGINE MODEL Detroit Diesel 8163-7416 1232HP
ENGINE NO. 16VF013546
RPM 1,800
Cylinder 16
Injection method Direct injection
Cooling method Water Cooled
Fuel consumption rate 246â??/h
GENERATOR SPECIFICATION (AC Generator, 3Ã??, 60Hz, Brushless type
Generator Model DIG 4800
Emergency output 990 kVA / 792 kW
Continuous output 900kVA / 720kW
Voltage and Current 600 v x 86.6 A
Revolution 1800RPM
Excitation Voltage/Current 65V/10A
Power Factor 80%
Insulation Class F
GOLD Member
Nov-13-24
Supplier From Bhavnagar, Gujarat, India
Diesel Engine and Generators
GOLD Member
VERIFIED
Jan-15-19
Supplier From Rajkot, Gujarat, India
We Are A Prominent Organization Engaged In Offering A Wide Range Of Generator Parts, Electrical Goods, Lubricants Oil, Industrial Ancillaries, Construction Equipment Parts. These Products Are Highly Durable And Cater To The Requirements Of Diverse Industries.
Sep-28-22
EAC 825
Engine
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Sep-15-22
EAC 790
Engine: CUMMNS
Engine Model : KTA38-G1
Stand By kVA: 790
Stand By kW : 632
Prime kVA: 718
Prime kW : 574
Rated Current : 1033

Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed

Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)

Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system

Engine CUMMNS
Engine Model KTA38-G1
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 701 / 953
Prime Power Hp 634 / 862
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 158
Lt %75 LOAD 122
Lt %50 LOAD 86

Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8

Weight (Silent) Kg 9200
Weight (Open) Kg 8050
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Aug-04-22
EAC 750
Engine: CUMM NS
Engine Model : QSK19-G11
Stand By kVA: 740
Stand By kW : 592
Prime kVA: 672
Prime kW : 538
Rated Current : 968

Engine
CUMM NS heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed

Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm

Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)

Optional
Thermal magnetic CB (for automatic models)
Super Silent Canopy
Mobile Generator Sets
Automatic fuel filling system
Synchronization panel
3 Pole and 4 Pole ATS (Automatic Transfer Switch)
Fuel Heater, Oil Heater
External fuel tank and automatic fuel filling system
Fuel - water separator filter
Remote monitoring and control system

Engine CUMM NS
Engine Model QSK19-G11
Number of Cylinders 6 - Inline
Injection System Direct
Compression Ratio 15.9 : 1
Bore 159
Strok 159
Displacement lt 19
Air Intake Turbo Aftercooler
Speed (RPM) 1500
Oil Capacity lt 80
Standby Power kW / Hp 667 / 907
Prime Power kW / Hp 606 / 827
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity lt 42
Fuel Consumption (lt / h) lt Full Load 135
lt %75 LOAD 103
lt %50 LOAD 69,5

Frequency Hz 50
Power kVA 740
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8

Weight (Silent) Kg 5750
Weight (Open) Kg 4900
Width (Silent) mm 1900
Length (Silent) mm 4800
Height (Silent) mm 2700
Fuel Tank Capacity lt 1350

1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jul-26-22
EAC 690
Engine: CUMM NS
Engine Model : KTAA19-G6A
Stand By kVA: 690
Stand By kW : 552
Prime kVA: 630
Prime kW : 505
Rated Current : 910
Engine
- CUMM NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM NS
Engine Model KTAA19-G6A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.0:1
Bore 159
Strok 159
Displacement L 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity L 38
Standby Power kw / Hp 610 / 825
Prime Power kw / Hp 554 / 750
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 75
Fuel Consumption (lt / h) L Full Load 148,3
L %75 LOAD 112,7
L %50 LOAD 76,4
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5200
Weight (Open) Kg 4530
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity L 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Jul-07-22
EAC 650
Engine: CUMMNS
Engine Model : KTAA19-G6
Stand By kVA: 650
Stand By kW : 520
Prime kVA: 590
Prime kW : 472
Rated Current : 849
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model KTAA19-G6
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.0:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 38
Standby Power kw / Hp 570 / 770
Prime Power Hp 518 / 700
Fuel Type Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 75
Fuel Consumption (lt / h) Lt Full Load 140
Lt %75 LOAD 104,9
Lt %50 LOAD 74,5
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5190
Weight (Open) Kg 4510
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity Lt 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.

Verification Status