Getein1600 immunofluorescence quantitative analyzer is a bench-top diagnostic analyzer. Combined together with bar-coded, ready-to-use strip cassettes, getein1600 is designed to deliver accurate testing results in minutes. The elegant design makes getein1600 can be used to great advantage in both routine and emergency testing situations in the clinical arena. Considering its superior performance, compact design, easy of use, and minimal maintenance, getein1600 is the optimal choice for clinics, research laboratories, and biotechnology companies.
Assay method
Lateral flow chromatograpgy (immunofluorescence)
Test resultquantitative
Sampling materialwhole blood, plasma, serum, urine
Language
English/chinese
(spanish, french, german, russian, arabic, vietnamese etc. Are under developing)
Display10.4 inch lcd screen; resolution 800 x 600
Printerinternal thermal printer
Working environment
Relative humidity < 70%
Air pressure 70.0kpa ~ 106.0kpa
Power supplyac 100~240v, 50~60hz
Data storage10, 000 results can be saved
Dimensions
Height 620mm
Width 410mm
Length 530mm
Weight55 kg
Test items
Cardiac marker
Ctni, nt-probnp, d-dimer, ck-mb, nt-probnp/ctni, ck-mb/ctni
Ck-mb/ctni/myo, hfabp, ck-mb/ctni/hfabp
Renal function
Cysc, malb, ngal, 2-mg
Inflammation monitoring
Hs-crp+crp, pct
Diabetes
Hba1c
Fertility
Hcg+
Getein1100 Immunofluorescence Quantitative Analyzer is an advanced on-site diagnostic analyzer, intended to deliver accurate testing results in minutes just from 3-4 drops of human specimens. Thanks to its simple design and small footprint, Getein1100 becomes an ideal system for emergency department, intensive care unit, or anywhere treatment and research needed at the point of care.
Fia8600 quantitative immunoassay analyzer is a medical diagnostic instrument which can be used to measure a variety of biomarkers in human whole blood, serum, plasma or other specimens. Due to its portable and light weight design, the fia8600 can be easily deployed at patient side, facilitating the clinical decisions with its rapid results. Fia8600 offers testing of cardiac markers, inflammation monitoring, diabetes, fertility, and renal function. Test items Cardiac marker Ctni, nt-probnp, d-dimer, ck-mb, nt-probnp/ctni, ck-mb/ctni, Ck-mb/ctni/myo, hfabp, ck-mb/ctni/hfabp Renal function Cysc, malb, ngal, î-mg Inflammation monitoring Hs-crp+crp, pct Diabetes Hba1c Fertility Hcg+î
Fia8000 quantitative immunoassay analyzer is a medical diagnostic instrument which can be used to measure a variety of biomarkers in human whole blood, serum, plasma or other specimens. Due to its portable and light weight design, the fia8000 can be easily deployed at patient side, facilitating the clinical decisions with its rapid results. Fia8000 offers testing of cardiac markers, inflammation monitoring, diabetes, fertility, and renal function.
H-fabp fast test kit (immunofluorescence assay) is intended for use together with getein1100 immunofluorescence quantitative analyzer (getein1100) or getein1600 immunofluorescence quantitative analyzer (getein1600) to quantitatively determine the concentrations of h-fabp in human serum, plasma, or whole blood specimens in point-of care and laboratory settings. H-fabp fast test kit (immunofluorescence assay) is intended for in vitro quantitative determination of heart-type fatty acid binding protein (h-fabp) in serum, plasma or whole blood. This test is used in the early diagnosis of ami and pulmonary embolism, and monitoring of chronic heart failure.
The cardiac troponin i fast test kit (colloidal gold) is intended for use together with the fia8000 quantitative immunoassay analyzer (fia8000). The product employs colloidal gold immunochromatogrphy to determine ctni in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify ctni specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of ctni. Then insert test card into the fia8000 quantitative immunoassay analyzer, the concentration of ctni is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for NT-proBNP (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine NT-proBNP in human serum, plasma, or whole blood specimens. One monoclonal antibody and one polyclonal antibody are employed to identify NT-proBNP specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of NT-proBNP. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of NT-proBNP is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for PCT (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine PCT in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify PCT specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of PCT. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of PCT is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for NAGL (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine NGAL in human urine specimen. Monoclonal antibody and polyclonal antibody are employed to identify NGAL specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of NGAL. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of NGAL is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for B2-MG (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine B2-MG in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify B2-MG specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of B2-MG. Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of B2-MG is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.