Quick test mode
Precise results
Ease of use
Internal memory storage and external memory on usb device
Compact size saves lab space
Automatic buffer calibration with buffer recognition
Battery backup for up to 4 hours with low battery indication
Auto power off after 10 minutes
Print facility using usb storage device
Stirrer interface to control rpm
Simultaneous display of ph, millivolt, conductivity and temperature
Atc temperature sensor
4-line lcd display
In built 8.4 v cvcc adaptor cum charger which takes care of power fluctuations
Built-in time and date function
Dimension:280 mm (w)x210 mm (d)x90 mm (h)
Weight:1 kg
GF312B portable three phase energy meter calibrator with printer is used to calibrate three phase, single phase, active and reactive energy meters error. The instrument has a micro printer and portable design. It is very suitable for on-site calibration of electric energy meters. Feature: 1.accuracy:0.05%,0.1%,0.2% 2.Test range:0-600V; 3.With printer 4.Harmonic:2-64times 5.Weight: 12kg 6.IP65
Conductivity meter
Quick test mode Precise results Ease of use Internal memory storage and external memory on usb device Compact size saves lab space. Automatic buffer calibration with buffer recognition Battery backup for up to 4 hours with low battery indication Auto power off after 10 minutes Print facility using usb storage device Stirrer interface to control rpm Simultaneous display of ph, millivolt, and temperature Atc temperature sensor 4-line lcd display In built 8.4 v cvcc adaptor cum charger which takes care of power fluctuations Built-in time and date function 280 mm (w)x210 mm (d)x90 mm (h) Approximate: 1 kg.
PHS-1701 Portable pH Meter PHS-1701 portable pH meter is a digital display PH meter, with LCD digital display, which can display PH and temperature values simultaneously. The instrument applies to the labs in junior college institutions, research institutes, environmental monitoring, industrial and mining enterprises and other departments or field sampling to determine the aqueous solutions PH values and potential (mV) values. Equipped with ORP electrode, it can measure the solutions ORP (oxidation-reduction potential) value; equipped with the ion specific electrode, it can measure the electrode potential value of the electrode. Technical Indexes Measuring range pH 0.00â?¦14.00 mV -1999â?¦1999 Temp -5---105 Resolution pH 0.01pH mV 1mV Temp 0.1 Electronic unit measurement error pH ±0.01pH mV ±1mV Temp ±0.3 pH calibration 1point, 2 point, or 3 point Isoelectric point pH 7.00 Buffer solution 8 groups Power supply DC6V/20mA 4 x AA/LR6 1.5 V or NiMH 1.2 V and chargable Size/Weight 230 100 35(mm)/0.4kg Display LCD pH input BNC resistor >10e+12 Temp input RCA(Cinch) NTC30k Data storage Calibration data 198 groups measurement data 99 groups for pH ?mV each) Working condition Temp 5...40 Relative humidity 5%...80%(without condensate) Installation grade Pollution grade 2 Altitude
Quick test mode Reading stability indicator Precise results Ease of use Internal memory storage and external memory on usb device Compact size saves space in your lab. Battery backup up to 4 hours with low battery indication Auto power off after 5 minutes Print facility using usb storage device Usb port for pc interface (at factory calibration) Stirrer interface to control rpm Simultaneous display of conductivity and temperature Atc temperature sensor 4-line lcd display In built 8.4 v cvcc charger adaptor which takes care of power fluctuations Built-in time and date function Dimension:280 mm (w)x210 mm (d)x90 mm(h) Weight:1 kg
Functions: It can measure pH,mV(ORP) and temperature. LCD display, English operation system Automatic and manual temperature compensation, self-calibration, and self-calculation of electrode percentage theoretical slope Five types of pH buffer solution can be chosen to conduct automatic calibration (one point or two points) Test results can be stored, deleted, viewed and printed. The amount of data can reach the maximum of 200 sets. It has RS-232 interface, and it can be connected to TP-16 printer. Also, the interface can be used to connect data collecting software and computer. It can be used to measure pH value of ultrapure water, pure water and boiling water by adjusting equipotential point and choosing specific electrode. It is equipped with E-201-C pH combined electrode and T-818-B-6 temperature electrode. Specifications: 1.Measuring range pH£º(0.000~14.000)pH mV£º(-1999.9~1999.9)mV Temperature: (-5.0~105.0)¡æ 2.Resolution pH£º0.1pH¡¢0.01pH¡¢0.001pH mV£º0.1mV Temperature: 0.1¡æ 3.Accuracy: pH£º¡À0.005pH¡À1 bit mV£º¡À0.2mV (¡À399.9mV) ¡À0.03% FS Temperature:¡À0.3¡æ¡À1 bit 4.Input impedance>=3¡Á1012¦¸ 5.Stability:£¨¡À0.005pH¡À1bit£©/3h 6.Temperature compensation range: Manual/Automatic(-5.0¡«105.0)¡æ 7.Power supply: DC power (9V DC£¬300mA£¬inside positive and outside negative) 8.Dimension(mm)£º280¡Á210¡Á90 9.Weight: 1kg 340*270*280mm/unit 2.5kg
Ph, tds and temperature meter Specifications ym-2006 Range Ph: 0.00 -- 14.00ph ec:0.00 -- 19.99ec C: -50pc -- 70pc pf; _58pf -- 158pf Cf: 0.0 -- 199cf tds: 10 -- 19990ppm Resolution: Ph: 0.01ph pc: 0.1pc pf: 0.2pf Ec:0.01ec cf:0.1cf tds:10ppm Accuracy Ph:+/- 0.10 ph pc:1.0pc Ec=cf=tds:+/- 2% f.S Operating temperature:0pc-- 50pc Automatic temperature compensation:0pc--50pc Batteries:dc6vor4x1.5v(ag13) Dimensions:155x86x22mm Weight:222g 100/1
DDS-1702 Portable Conductivity Meter DDS-1702 Portable Conductivity Meter is an instrument used for the measurement of the conductivity of aqueous solution in the laboratory. It is widely used in petrochemical industry, bio-medicine, sewage treatment, environmental monitoring, mining and smelting and other industries as well as junior college institutions and research institutes. If equipped with conductivity electrode with the appropriate constant, it can also be used to measure the conductivity of pure water or ultra-pure water in electronic semiconductor or nuclear power industry and power plants. Technical Indexes Measure Range Conductivity 0.00 S/cm199.9 mS/cm TDS 0.1 mg/L 199.9 g/L Salinity 0.0 ppt80.0 ppt Resistivity 0.cm 100M.cm TemperatureATC/MTC -5105 Resolution Conductivity / TDS / salinity / resistivity Automatic sorting Temperature 0.1 Electronic unit error Conductivity ±0.5 % FS Temperature ±0.3 Calibration 1 point 9 preset standards (Europe and America, China , Japan) Data storage Calibration data 99 measurement data Power requirements 4xAA/LR6(No. 5 battery) Monitor LED monitor Shell ABS
Feature: 1.Convenient, efficient and accurate. 2.LCD digital display, easy to read. 3.Auto shut-off after 10 minutes\' non-use. 4.Long battery life. 5.Many kinds of packages for your choice (pp bag, leather case,etc). Advantages: 1.100% quality guarantee. 2.Quick delivery time. 3.OEM ODM service. 4.Promptly reply you within 24 hours. 5.We treat clients as friend .Giving best service and sincere greetings. Warranty: 1.12 months Manufacturer`s limited Warranty for defective items (excluding items damaged and/or misused after receipt). Accessories come with a 3-month warranty. 2.Defective items MUST BE reported and returned within the warranty period (and in the original packaging, if possible). You must tell us what the defect is and give us your order number. WE DO NOT REPAIR OR REPLACE ITEMS WITH AN EXPIRED WARRANTY. Note: 1.The instrument is a professional instrument, please under professional instructions in order to avoid instrument failure. 2.Avoid heat, direct sunlight. 3.Please adopting standard buffer solution calibration, incorrect calibration would cause measurement error, thus affecting the accuracy of the test solution, or cause the instrument not working properly. 4.Do not thrown the instrument into the test solution to avoid the circuit board short circuit.