**Ready stock in Turkey** -Price: USD11,000/CIF by air *without compressor -Price: USD12,000/CIF by air *with compressor -Operation Features- Inspiration Pressure: 2-100 mBar Inspiration Duration: 0.1-10 Sec. Peep Pressure: 0-50 mBar Breathe Speed: (c) 1-150/mins. (y) 1-100/mins. Flow: (c) 1-60 lt/mins. (y) 2-120 lt/mins. O2 Mixture: 21-100% Spontaneous Pressure Support: 0-100 mBar I/E Rate: 1:10 (x60*)-10:1 (c): Child, (y): Adult
Kubba Tactical Knee Pads Function: The knee joint is fixed, which improves the stability and strength of the knee, reduces the burden of the knee ligament when raising the leg and jumping, and enhances the protection of the knee ligament, with good air permeability and comfortable wearing feeling. Specification for elbow pads: Plastic protective block: PVC, Fabric: 600D Oxford cloth, Buffer layer: 15mm thick EVA foam sheet Lining: Mesh Army green color, with embroidered  Kubba  logo 6.Impact resistance: withstand the impact of 120 kinetic energy Structure: The plastic protective block is to resist hits and collisions and disperse the impact force. The middle foam absorbs impact energy Suitable environment temperature: -20~+55 Weight: 0.18kg/ pair Specification for knee pads: Plastic protective block: PVC, Fabric: 600D Oxford cloth, Buffer layer: 15mm thick EVA foam sheet, Lining: Mesh Army green color, with embroidered  Kubba  logo Impact resistance: withstand the impact of 120 kinetic energy Structure: The plastic protective block is to resist hits and collisions and disperse the impact force. The middle foam absorbs impact energy Suitable environment temperature: -20~+55 Weight: 0.25kg/pair
OCTACARE WAIST CORSETS & KNEE BRACES Please Don't Hesitate To Contact Us In Case Of Any Interested
The Zimmer M/L Taper Hip Prosthesis is a product line from Zimmer Biomet, a company that specializes in orthopedic implants and devices. The M/L Taper Hip Prosthesis is used in hip replacement surgeries and consists of a femoral stem that is implanted into the patient's femur. The "M/L 12/14 Taper" designation likely refers to the taper of the femoral stem, with 12/14 indicating the taper size. The "Standard Offset" specification suggests a standard offset design for the femoral stem. The offset refers to the distance between the center of the femoral head and the center of the femoral stem. Standard offset is a common configuration, but there are also variations such as high offset or low offset stems to accommodate different patient anatomies. Key features and considerations for the Zimmer M/L Taper Hip Prosthesis may include: Material: The femoral stem is typically made of biocompatible materials such as titanium or cobalt-chromium alloy. Taper Design: The taper design facilitates the connection between the femoral stem and the femoral head component. Modularity: Some hip prostheses, including those with taper connections, offer modularity, allowing surgeons to choose different head sizes and neck lengths to optimize patient fit. Surgical Technique: Implantation involves removing the damaged part of the hip joint and replacing it with the prosthetic components. Range of Motion: The design aims to provide stability, durability, and a suitable range of motion for the patient.
Hand function position fixed splint (AJY-S09) It is used for the fixation of stable fractures of the hand and wrist, the fixation of neuromuscular and tendon injuries, and the fixation of functional positions after orthopaedic surgery. Prevent deformity caused by bone and joint disease in thumb-to-finger and palm-to-hand positions shape. 337*170*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Hand rest position fixed splint (AJY-S08) It is used for fixation after orthopedic surgery such as hand and wrist fractures, nerve tendon injuries, scar contractures, etc., to prevent or correct the deformities caused by bone and joint, neuromuscular disease. 360*210*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb-fixed splint (Herringbone) AJY-S02 It is used for thumb metacarpal bone, acute metacarpal arthritis, thumb sprain, rheumatoid arthritis, post-tiger occidental occidental surgery and thumb function fixation after median nerve injury. 200*165*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
I can provide general information about guide wires used in medical procedures. Guide wires play a crucial role in various interventional procedures, such as angiography and angioplasty, where they are used to navigate through blood vessels and provide a pathway for the delivery of catheters and other medical devices.