Maximum Working Pressure1.6MPa
Accuracy ClassClass 2 (ISO4064:2005, Class 1 upon request)
Temperature ClassT30, T50 (Higher temperature upon request)
Battery Life20 years
Ingress ProtectionIP68
Environment Temperature-20~70oC, 100%RH
Pressure Loss
Climatic and Mechanical EnvironmentClass C
Display8 digit LCD Display + prompts
Cumulative flow (m3), Instantaneous flow (m3/h), Battery Level, Date and Time, etc.
ConnectionsThreads (DN15-40), Flanges (DN50-300) according to ISO
Electromagnetic Environment ClassE2
Flow Profile SensitivityU0/D0
Superior Hydraulic Design, Without Installation Requirements Of Straight Pipe Wide Turndown Ratio, R is Up To 1000Suitable For Big Volume Flow And Tiny flow Measurement. Suitable For Mass Flow And Tiny Flow Measurement The Design Of Integrated Flow, Pressure, Wireless Reading Meets Monitoring Pipeline Requirement IP68 Protection Class, Whole Meter Sealed Completely Ensures Long Term Underwater Working Double D Size Batteries Can Continuously Work For 15 Years Bi-directional Measuring Forward And Reverse Flow Data Logger Function Can Save 10 Years Data Including Day, Month And Year LCD Display Volume, Flow Rate, Flow Direction, Alarm, Leak Detection At The Same Time Standard RS485 (Modbus-RTU), A Variety Of Options, NB-IOT, OCT, GPRS etc. Electric Components According To ROHS, OSP Processed Circuit Board Stainless Steel Body (SS304) is Integrated Stretching Patent Right Product International Standard Flange Connection, Simple Installation According To Sanitary Standard For Drinking Water
Superior Hydraulic Design, Without Installation Requirements Of Straight Pipe Wide Turndown Ratio, R is Up To 1000Suitable For Big Volume Flow And Tiny flow Measurement. Suitable For Mass Flow And Tiny Flow Measurement The Design Of Integrated Flow, Pressure, Wireless Reading Meets Monitoring Pipeline Requirement IP68 Protection Class, Whole Meter Sealed Completely Ensures Long Term Underwater Working Double D Size Batteries Can Continuously Work For 15 Years Bi-directional Measuring Forward And Reverse Flow Data Logger Function Can Save 10 Yearsâ??Data Including Day, Month And Year LCD Display Volume, Flow Rate, Flow Direction, Alarm, Leak Detection At The Same Time Standard RS485 (Modbus-RTU), A Variety Of Options, NB-IOT, OCT, GPRS etc. Electric Components According To ROHS, OSP Processed Circuit Board Stainless Steel Body (SS304) is Integrated Stretching Patent Right Product International Standard Flange Connection, Simple Installation According To Sanitary Standard For Drinking Water
GMF200-W ultrasonic water meter is designed for water metering settlement and production of a high performance products, with the remarkable features of low power consumption, wide measuring range ratio, stable and reliable measurement .Each component reaches IP68 protection class, to ensure long term operation though water in the inside meter.
Ultrasonic water meter is a new type of water meter that detects the time difference caused by the speed change when the ultrasonic sound beam propagates in the water upstream and downstream, analyzes and processes the water velocity, and further accumulates the water flow rate. It can be widely used in water supply metering of water supply companies and used to measure cold drinking water flowing through water pipes. The technical indicators and performance of the product meet the following standards GB/T 778 series standards and the factory verification is based on the JJG 162-2009
Ultrasonic water meter is a new type of water meter that detects the time difference caused by the speed change when the ultrasonic sound beam propagates in the water upstream and downstream, analyzes and processes the water velocity, and further accumulates the water flow rate. It can be widely used in water supply metering of water supply companies and used to measure cold drinking water flowing through water pipes. The technical indicators and performance of the product meet the following standards: The product meets the National Standards of the People's Republic of China GB/T 778 series standards and the factory verification is based on the JJG 162-2009 "Cold Water Meter" verification regulations.
Use ultrasonic flow measurement technology, no mechanical moving parts drift diameter design, no pressure loss, cut down the electric consumption of the pump and help untilities reduce cost. Features: Low in initial flowrate, and the min. Flow velocity measured is0.002 m/s; Measurement cycle 1 time per second, battery powered (One battery can work continuously for 6 years); Multi-channel construction design, double cross section measurement, and be able to ensure the measurement accuracy to the largest extent; Be able to work at any flow point for long time; IP68 of the whole meter, for each unit of the meter is IP68 designed; Micro-consumption design, less than 0.0008W; Drift diameter design, no pressure loss. Operating on velocity-difference principle, the LG-UWM68 series is specially designed for urban water supply and building-use. The conventional water meters suffer from the drawbacks that they are only operable at a higher flowrate and are insensitive to a small flowrate. However, the LG-UWM68 series water meter can help tackle the bottleneck. And the meter is highly adaptable to diversified industrial conditions Due to the use of ultrasonic flow measurement technology, it has no mechanical moving parts drift diameter design, no pressure loss, cut down the electric consumption of the pump and help the enterprises reduce cost Be able to work at any flow point for a long time and high in reliability, immune to magnetic interference Battery-powered capable of operating continuously for a period of over 6 years with a single cell High sensitive to minimal flowrate and high in measuring accuracy Capable of performing various output function, and it is capable of making wireless transmission of meter reading to form a monitoring system via the GSM network to monitoring the meter's running status and the pipe network conditions. Three design versions are available, i. e. The ordinary version, 2-way version and fire water version are cater to different needs of users Ordinary version: Measurements of the flowrate and cumulative running time in positive direction 2-way version: Capable of measuring flowrate, cumulative flowrate cumulative running time in positive/reverse direction; Fire water version: Much bigger range ratio, and specially designed for fire water. CE: 2004/108/EC The meter is in conformity with Standard on Measurement of Water Flow in Fully Charged Closed Conduits_Meters for Cold Potable Water and Hot Water GB/T 778-2007-a standard is issued by the People's Republic of China L Ex-factory calibration of the meter is made in conformity with Standard on Water Meter for Potable Cold Meter JJG162-2009- a standard is issued by the People's Republic of China.
RS485 Pulse Output Signal Digital Flange Inline Type Ultrasonic Water Flow Meter Newest Product TUF-2000F2 1. Protection Class: IP68 2. Pipe Size: DN15~DN6000 3. The main unit suits to install on the pipe, all parts achieve to IP68. Adapt to many severe working environment. 4. OEM supported.
LXLG-80-400 Detachable Horizontal Spiral Wing Pulse Water Meter with Flange Connection #watermeter #smartwatermeter #smartmeter #intelligentwatermeter #digitalwatermeter #remotewatermeter
High accuracy : It is a high sensitivity water meter that detects a little flow with R200 high accuracy. Battery Life: The low-power design enables the water meter to last longer than 10 years.