Ac to dc battery charger
(12v/24v/48v, 5a/10a/20a/40a)
Special features:
1. Led indicator light show charging status.
2. Temperature controlled cooling fan.
3. 3-stage battery charging: bulk charge, absorption charge, float charge
4. Switch mode technology
5. High efficiency and led visual display
6. Protection: over temperature, short circuit, reverse polarity
Inner box and carton
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc ( +10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80 C. When the DC panel has a temperature over 100 C, the module will stop working; when the DC panel has a temperature below 90 C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Product Introduction SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module. Unique function High efficiency over the full load range, full load efficiency greater than 95.5% Wide output voltage range, 100-1000VDC, suitable for a wide range of Lithium and lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main features Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Three phase active power factor correction technology, reduces the harmonic interference to the grid Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Soft start charging and soft shutdown minimize the impact on the battery. Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. CAN/RS485 interface
Product Introduction SANDI AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module. Unique function High efficiency over the full load range, full load efficiency greater than 95.5% Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main features Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Three phase active power factor correction technology, reduces the harmonic interference to the grid Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Soft start charging and soft shutdown minimize the impact on the battery. Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. CAN/RS485 interface (Optional)
Skyrc q200 is a quad-channel charger with 4 independent circuits, which can charge four different kinds of batteries simultaneously. The charger adopts a 480ã?320 color lcd display, and paired channels (a&c or b&d) support power distribution in ac mode. Moreover, users could either connect it to pc or mobile device to further expand their using experience. Firmware upgrade is available via pc software interface. Input voltage ac100-240v / dc 11-18v Charge circuit power dc input: ch a/ch b: 100w ch c/ch d: 50w Ac input: ch a+ch c=100w ch b+ch d=100w; Ch a/ch b: 50-100w ch c/ch d: 0-50w Discharge circuit power 4 x 10w Charge current range ch a/ch b 0.1-10a Ch c/ch d 0.1-5a Discharge current range 0.1-2a x 4 Current drian for balancing port max 200ma/cell Trickle charging current 50ma-300ma & off Lipo/life/lilon/lihv battery cell count 1-6s Nimh/nicd battery cell count 1-15s Pb battery voltage 2-20v Dimension 197*182*71mm Net weight 1335g
Product Introduction SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module. Unique function High efficiency over the full load range, full load efficiency greater than 95.5% Wide output voltage range, 100-1000VDC, suitable for a wide range of Lithium and lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main features Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Three phase active power factor correction technology, reduces the harmonic interference to the grid Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Soft start charging and soft shutdown minimize the impact on the battery. Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. CAN/RS485 interface
Our DC-DC converters and rectifiers are designed for telecommunication and industrial use only. Full customization and custom-specific designs can be provided. Detailed brochure available.
energy storage bidirectional converter, the hardware system adopts DSP FPGA architecture, which breaks through the limitation of data processing capability of traditional DSP architecture and realizes more optimized, efficient and flexible algorithm. The overall architecture adopts high-quality cabinet and innovative heat flow field design, thus ensuring long-term stable operation of the converter in extreme harsh environment
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".