Jun-26-14

reading capability
Interferential filters¡¨ºo2 precision filters (450 and 630 nm); 2 more on request (4 filters max, 400-700nm)
Reading¡¨ºoreading from 0.000 to 3.000 od; inaccuracy ¡¡§¡è 1% from 0.000 to 1.500 od, ¡¡§¡è 2% from 1.500 to 3.000 od
Software¡¨ºowork list set up, patient reports and result filing; calibration curve storage for each carried out test

113 x 77 x 75 h


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Auto Elisa Processor

Jun-26-14
Supplier From Jinan, Shandong, China
GOLD Member
Feb-26-25
Supplier From Seongnam-si, Gyeonggi-do, South Korea (Republic Of Korea)
 
AISG - Artificial Intelligence Scalp Grader: This AI-powered system analyzes scalp conditions, identifies 10 scalp types, and provides personalized care solutions. Developed with Seoul National University Bundang Hospital, it offers customized shampoos and serums with a 93% satisfaction rate, improving scalp health by 50% in just four weeks. Ideal for salons and clinics.

Artificial Intelligence Customized Scalp Cosmetics Service System:
The AI Scalp Analysis and Custom Care System leverages advanced artificial intelligence through its Scalp Analyzing System to evaluate scalp type, hair density, thickness, condition, and hair loss type using photography and interviews. This data-driven approach enables the immediate creation of personalized scalp care products, including shampoo, scalp serum, and hair treatments, tailored to individual needs.

SPECIFICATION:
ITEM: Artificial Intelligence (AI) Scalp Analysis System [ASM-224S]
Processor: ARM Cortex A 7 [Octa Core]
Memory : eMMC 32 GB
OS : Android 6.01 [ Marshmallow ]
Image Camera Sensor : Dual Camera Sensor - 1/4 inch Color CMOS [5 Mega Pixel]
X1 Camera Sensor / High Magnification Camera Sensor
Sensor Pixel Total Pixel: 5,038,848 Pixel / Effective Pixel: 4,915,200 Pixel
Image Capture Size: VGA: 640 (H) X 480 (V) / 5 M: 2592(H) X 1944(V)
High Magnification Lens: X 60 / X 500 / CT
Focusing VCM Auto Focusing / VCM Manual Focusing
Touch LCD Type : C-Touch TFT LCD / Size: 5.5 inch / Resolution: FHD [1080 X 1920]
Battery Type : Li-Ion / Typical Capacity: 3,000mAh / Normal Voltage: 3.7V
Display Mirroring : HDMI / Wi-Fi [Wireless LAN] : Smartphone / Tablet [iOS, android] / PC [Windows, Mac]
VERIFIED
Nov-16-22
Supplier From Akbarpur, Uttar Pradesh, India
VERIFIED
Aug-30-23

Hcg Stripes

$0.03
MOQ: Not Specified
Supplier From Akbarpur, Uttar Pradesh, India
 
Our HCG Strips are a reliable and user-friendly solution for at-home pregnancy testing. These highly sensitive strips are designed to detect the presence of human chorionic gonadotropin (HCG) hormone in urine, a hormone produced during pregnancy.

With their simple, dip-and-read design, these strips provide quick and accurate results within minutes. A clearly visible test and control line make interpretation effortless, even for first-time users. Our HCG Strips are manufactured with precision, ensuring consistent and dependable results. These strips offer privacy and convenience, empowering individuals to confirm pregnancy discreetly and with confidence in the comfort of their own homes.
VERIFIED
Oct-25-23
Supplier From Akbarpur, Uttar Pradesh, India
 
The Carbon Dioxide Incubator is a vital medical equipment utilized in hospitals for cell culture and research applications. It provides a controlled environment for cells, tissues, and cultures, mimicking physiological conditions. This incubator maintains precise temperature, humidity, and CO2 levels, ensuring optimal growth and viability of biological specimens. Equipped with advanced CO2 sensing and digital controls, it offers unparalleled accuracy and stability. The spacious interior accommodates various culture vessels. Its robust construction, contamination prevention features, and alarms guarantee aseptic conditions. Hospitals rely on CO2 incubators for critical tasks such as tissue culture, IVF, and microbiological research, making it an essential asset in healthcare and research.
May-26-20
Supplier From Beijing, China
Jun-20-11
 
Test Method:Dispersion light nephelometric analysis

Test Principle:The highest point on first order differentiation,Percentage analysis

Zero point correction:auto track the zero point,eliminate the interference of sample and reagent

Wavelength:470nm

Light Source:Cold Lamp with high brightness and long lifetime

Detector:unique Dispersion light detector with high sensitivity and repeatability,immunized the effect on result of jaundice¡¢hemolysis¡¢chyle and turbidity on plasma

Test Channel:each channel is independent,one or more,same or different items can be tested Simultaneously

Incubator:Provide reagent and sample with stable incubator,

Incubator Temperature:37¡À0.2oC

Measure trigger:Auto trigger the measurement through configured pipette

Item modify:easy to add or edit items,easy to set the items parameters

Calibration:single-point calibration;multipoint calibration;auto store and match with calibration curve

Quality control:auto draw the quality figure

Reagent:open reagent system

Reagent volume:40

Sample volume: 40

Memory:Save more than 10000 samples results,and auto recovering the results when power is off during working

Repeatability:CV¡Ü5%

Calculative item:S¡¢%¡¢PTR¡¢INR,Fib can be get through PT,This leads to lower the cost of reagent

Printer:Inner thermal printer,can be connected to external printer

Information edit:easy to input and edit the detail information of patients

Interface:RS-232 serial port,can be connected to external printer

Working Environment:Temperature:10 oC~30 oC Humidity: ¡Ü70%RH

Voltage:85-264V,Auto adapt according to the input voltage

Power: ¡Ü80W

Quality System:Recognized by CE,TUV and CMD

Test Items

PT
AT-¢ó

APTT
Protein-S

TT
Protein-C

Fib
LA

RepT
Hep

VT.



260mm*257mm*133mm
3.6kg.
Feb-04-10
Supplier From Caltanissetta, Italy
 
A series EAGLE is composed of two models for electrosurgery which can all be connected to an independent Argon gas module and max. powers of 400 W and 280 W; there is also one model for electrosurgery which built in Argon gas and max. power of 400 W. The units have got 17 currents: 10 for the monopolar usage and 7 for the bipolar usage. Three for the monopolar cut, Three for the monopolar cut, Four for the monopolar coagulation, Two for the bipolar cut, Two for the bipolar coagulation, Two for the bipolar coagulation, One for the coagulation / sealing of big vessels. All the output currents are completely self controlled through a micro-processor with three different systems: - ADC System - APC System - Starting impulse control, which electronically checks the starting pulse of the cut currents. The EAGLE models are equipped with a circuit that can verify the connection/contact of the neutral electrodes ônon Splitö type with a single section and ôSplitö type with a double section with interrupts delivery of the power and luminous acoustic alarm signal. The units can be used with one double pedal footswitch, which allows the activation of the monopolar or bipolar functions, and with a second double pedal foot-switch, which is indicated for the independent activation of the bipolar functions only. The all models allow memorizing and then selecting through a simple button 100 complete functioning programs and are equipped with: two monopolar outputs, which can be used at the same time by two different operators through the Twin activation device; two bipolar outputs. All models are equipped with an auto-check system at double microprocessor: - Main Auto-Check, main auto-diagnosis procedure at the switching-on. - Standard Auto-Check, continuous check of all the functioning parameters during the usage. - Immediate interruption of the functioning with contemporary alarm signal for the operators through specific Error Codes HF Leakage Control, check of the high frequency leakage currents to earth. Auto-Check Argon section. Automatic output of the right modulated and pulsed spray coagulation when the Argon gas coagulation is activated independently from the type of coagulation selected for the simple electro-surgery, and selfcompensation of the gas flow according to the diameter of the electrodes, with a perfect control of the penetration depth. The units can be equipped with automatic activation aspirators that guarantee the efficacious and silent elimination of smokes or electro-surgical aerosol.
Oct-11-22
 
Product Details:
Usage/Application Laboratory
Brand J Mitra
Provided with 3wash bottles for switching off to3 different ELISA tests.

In built Incubator adjustable to required temperature (Ambient, 30�ºC& 37�ºC).

Provision for 2 ELISA PLATES (96T) incubation at a time

Inbuilt shaker provided for better washing

Accurate results due to cover lid as no Air Draft at the time of sample and Reagents incubation.

Provision of auto rinsing of tubes/probes & hence No cross contamination

CE MARKED

Verification Status