Monitor rod pump operation and periodically collect dynamometer, pressure, temperature and fluid level data.
An advanced algorithm used to control the rod pump operating at the optimized condition to improve energy efficiency.
Open IEC1131-3 programming environment for users to develop their specific application.
With an embedded RF module, the E5302 can communicate with wireless dynamometer sensor, wireless pressure transmitter, wireless temperature transmitter to build up a cost-effective wireless data acquisition system.
Provide three serial communication ports and one Ethernet port. It can be connected to many communication devices including AP, Radio, and GPRS DTU.
Support industrial standard Modbus RTU and E4100 protocols.
Remote controlled by central computer system.
Carton
The e5302 rod pump controller is an intelligent controller developed by echo technologies for the needs of oil and gas production. It is a combination of oil exploration, automation, communication, and computer technologies. It features well data acquisition, dynamometer graph, well condition analysis, and remote pump controlling. The e5302 rpc is a highly reliable controller and easy to use. The e5302 supports various communication methods. It can be used as an unattended rod pump control system, monitoring well condition, improving production efficiency, providing reliable operation, and saving cost. The e5302 is comprised of a controller and protection cabinet which is specifically designed for rain, sun and dust proof. With combinations of rod load sensor, rod position sensor and other instruments, the e5302 provides comprehensive information including dynamometer graph, pressure, temperature, motor voltage and motor current. The e5302 also provides wireless communication port for working with wireless field instruments to save cabling cost. The e5302 can work as an independent local controller or act as a remote substation for a scada system. Features Monitor rod pump operation and periodically collect dynamometer, pressure, temperature and fluid level data. An advanced algorithm used to control the rod pump operating at the optimized condition to improve energy efficiency. Open iec1131-3 programming environment for users to develop their specific application. With an embedded rf module, the e5302 can communicate with wireless dynamometer sensor, wireless pressure transmitter, wireless temperature transmitter to build up a cost-effective wireless data acquisition system. Provide three serial communication ports and one ethernet port. It can be connected to many communication devices m. Carton
S an independent local controller or act as a remote substation for a scada system. Features Monitor rod pump operation and periodically collect dynamometer, pressure, temperature and fluid level data. An advanced algorithm used to control the rod pump operating at the optimized condition to improve energy efficiency. Open iec1131-3 programming environment for users to develop their specific application. With an embedded rf module, the e5302 can communicate with wireless dynamometer sensor, wireless pressure transmitter, wireless temperature transmitter to build up a cost-effective wireless data acquisition system. Provide three serial communication ports and one ethernet port. It can be connected to many communication devices including ap, radio, and gprs dtu. Support industrial standard modbus rtu and e4100 protocols. Remote controlled by central computer system. Carton
YJV cables OR YJV22 cables are chinese designated cables, widely used in cranes and hoist cranes. Good thing is now united insulated cable co, manufactures YJV type series of cables in India, in aluminium and copper also. they are insulated with XLPE and Taped with Steel and inner and outer sheath is provided with HR-PVC.
Manufactured with Triple Tinned Annealed copper fine strands of 7 wires of 36 SWG. Insulated with Cable Grade Silicone rubber(Japanese Make) conforming to IS 9968 part I 0f 1988.
Supplier: Rubber cables, silicone cables, epr pcp vir trs eva cables, electric cables, control cables, pvc cables, thermocouples, rtd cables, extension cables, k, r, n, t, s type cables, compensating cables, led wires, cfl wires, led raw material, lighting cables, flood light cable, mining cables, crane cables, eot crane, hoist crane cables, kiln cables, copper strips, thermoplastic cables, tpr cables, natural rubber cables.
Buyer: Rubber epr/pcp/csp natural rubber, silicone rubber, tinned copper, bunched copper
Accu-Tell ®  Multi-Drug Saliva Rapid Test Cassette for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS) are the preferred confirmatory methods. Professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. TEST PROCEDURE of Drug Metabolites Rapid Test Allow the test cassette, specimen, and/or controls to reach room temperature (15-30 °C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection. 1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated. 2. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.  Discard the collector.  Snap the cap shut on the collection chamber. 3. Place the test cassette on a clean and level surface.  Unscrew cap cover from the collection chamber.  Invert the collection chamber and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer.  Avoid trapping air bubbles in the specimen well. Place screw cap on the collection chamber. See illustration above.  We are Drug Of Abuse Rapid Tests Supplier.
Accu-Tell ®  Multi-Drug Saliva Rapid Test Cassette for AMP/MET/COC/OPI/THC/PCP/MTD/MDMA/OXY/COT/BZO/KET/6-MAM is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in saliva. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS) are the preferred confirmatory methods. Professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. TEST PROCEDURE of Drug Metabolites Rapid Test Allow the test cassette, specimen, and/or controls to reach room temperature (15-30 °C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection. 1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated. 2. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.  Discard the collector.  Snap the cap shut on the collection chamber. 3. Place the test cassette on a clean and level surface.  Unscrew cap cover from the collection chamber.  Invert the collection chamber and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer.  Avoid trapping air bubbles in the specimen well. Place screw cap on the collection chamber. See illustration above.  We are Drug Of Abuse Rapid Tests Supplier.