The extraction condensing turbines are used when a constant pressure steam flow has to be extracted for process purposes. The constructional characteristics of these turbines are very similar to condensing turbines from the second admission valve chest it is possible to inject low pressure steam, available in the plant to supply the power required by the plant.
These turbines are typically used for co-generation where the turbine meets both the power and steam demand of the process plant. In these type of turbines the power generated can be maintained more or less at a steady level despite
Extraction condensing steam turbine The extraction condensing turbines are used when a constant pressure steam flow has to be extracted for process purposes. The constructional characteristics of these turbines are very similar to condensing turbines from the second admission valve chest it is possible to inject low pressure steam, available in the plant to supply the power required by the plant. These turbines are typically used for co-generation where the turbine meets both the power and steam demand of the process plant. In these type of turbines the power generated can be maintained more or less at a steady level despite variation in process steam demands. In some cases it may be necessary to have both bleed and controlled extraction steams from the condensing turbine. These turbines are of bleed cum extraction condensing type.
Turbines Manufactured For Atomic Energy Application Using Titanium Blades. We are manufacturing Steam Turbines with following range:- Back Pressure Steam Turbine Extraction Back Pressure Steam Turbine Condensing Steam Turbine Single Extraction Condensing Steam Turbine Double Extraction Condensing Steam Turbine Single & Multistage Steam Turbines Small Steam Turbines Ranging from 10 Kw
Manufacturer of World's Best Back Pressure Steam Turbines Upto 6 MW Range. We are manufacturing Steam Turbine with following range:- Back Pressure Steam Turbine Extraction Back Pressure Steam Turbine Condensing Steam Turbine Single Extraction Condensing Steam Turbine Double Extraction Condensing Steam Turbine Single & Multistage Steam Turbines Small Steam Turbines Ranging from 10 Kw
Proven reliability and high efficiency makes Kessels multi-stage steam turbines vital partners with the power and process industries. High fuel and energy conversion costs demand that steam turbine efficiency be as much a consideration as reliability. Kessels industrial multi-stage steam turbine line helps you meet a variety of energy requirements in industrial environments. These turbines operate at speeds up to 12,000 RPM, with steam inlet conditions up to 105 bar at 560oC, and exhaust conditions up to 12 bar.
Back pressure turbines can either be single stage or multi-stage which are often used in industrial plants, the turbine serves as a reducing station between boiler and the process steam header. These turbines can either be used for drive application (Sugar mill drives, Sugar fibrizor / Shredder drive, Pump drives and so on) or power generation application in which case the turbine drives the generator. These turbines are straight-back pressure type and find application where back pressure steam is fully utilized to meet process demands. The power generation is incidental to the process steam demand. The back pressure turbine may also have bleed points (uncontrolled extractions) to satisfy steam demands at intermediate pressures, This provision is applicable when the bleed (medium pressure) steam volume demand is low and pressure variations can be tolerated. These turbines are of bleed cum back pressure type. The back pressure turbine with one controlled extraction point is possible, this extraction steam is also used to meet process steam demand at intermediate pressure when volume demand is high and pressure variations cannot be tolerated. These turbines are of extraction cum back pressure type.
The condensing turbines take high pressure steam, expand it in turbine nozzles and blades, and exhaust it to a condenser at lower than atmospheric pressure. It is principally used when power must be generated with minimum steam consumption. The condensing turbine may also have bleed points (uncontrolled extractions) to satisfy steam e. These type of turbines find application mainly for power generation where bleed steam is required for feed water heating (hp heater, lp heater and deaerator requirement) and / or where bleed steam is utilized to meet small process demands.
Supplier: All industrial steam turbine, back pressure steam turbine, condensing steam turbine, extraction condensing steam turbine, mini steam turbine
Manufacturer: Siemens turbines Condition: used - guaranteed power: 53.570 KW - vapour pressure alive: 94,00 bar - live steam temperature: 518,00 - live steam flow: 189.02 t/h - inlet thermal load flow: 647,752,638 kJ/h - socket pressure a3: 17,581 bar - socket flow rate a3: 13,490 t/h - thermal load flow a3: 40,812,646 kJ/h - socket pressure a2: 7,292 bar(a) - outlet flow a2: 18,50 t/h - socket pressure a1: 1,181 bar(a) - tap flow a1: 14,54 t/h - heat load flow a1: 37,296,554 kJ/h - exhaust pressure: 0,107 bar(a) - turbine rotation: 6,415.4 rpm - service factor: 1,1 (over Pe) - input rotation: 6,415.4 rpm - output rotation: 1800 rpm - change effective: 284.2kN.m 1800rpm
Supplier: Turbine generators for example: condensing steam turbine, backpressure steam turbine, extraction condensing steam turbine, high-speed & high-efficiency steam turbine, also power distribution equipment. Power plant